PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

A novel electrode to achieve balance between anastomotic strength and tissue thermal damage for radiofrequency-induced intestinal anastomosis

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
This paper aimed to develop a novel electrode to achieve balance between anastomotic strength and tissue thermal damage for radiofrequency-induced intestinal anastomosis.
Rocznik
Opis fizyczny
Bibliogr. 31 poz., rys., tab., wykr.
Twórcy
autor
  • Shanghai Institute for Minimally Invasive Therapy, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China.
autor
  • Shanghai Institute for Minimally Invasive Therapy, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China.
Bibliografia
  • [1] DIENER M.K., SEILER C.M., ROSSIO I., KLEEFF J., GLANEMANN M., BUTTURINI G., TOMAZIC A., BRUNS CJ., BUSCH O.R., FARKAS S., Efficacy of stapler versus hand-sewn closure after distal pancreatectomy (dispact): A randomised, controlled multicentre trial, The. Lancet., 2011, 377, 1514-1522.
  • [2] DING W., Opportunities and challenges for the biodegradable magnesium alloys as nextgeneration biomaterials, Regen. Biomater., 2016, 3, 79-46.
  • [3] DODDE R.E., BULL J.L., SHIH A.J., Bioimpedance of soft tissue under compression and applications to electrosurgery, Physiol. Meas., 2012, 33(6), DOI: 10.1088/0967-3334/33/6/1095.
  • [4] DODDE R.E., MILLER S.F., GEIGER J.D., SHIH A.J., Thermal-electric finite element analysis and experimental validation of bipolar electrosurgical cautery, J. Manuf. Sci. E-T. Asme., 2008, 130(2), DOI: 10.1115/1.2902858.
  • [5] ELZAYAT S., ELSHERIF H., AOUF M., Trans-oral endoscopic assisted radio-requency for adenoid ablation; a randomized prospective comparative clinical study, Auris. Nasus. Larynx., 2021, 48, 710-717.
  • [6] FERRERO S., STABILINI C., BARRA F., CLARIZIA R., ROVIGLIONE G., CECCARONI M., Bowel resection for intestinal endometriosis, Best. Pract. Res. Cl. Ob., 2021, 71, 114-128.
  • [7] GONZÁLEZ‐SUÁREZ A., TRUJILLO M., BURDÍO F., A,DALUZ A., BERJANO E., Could the heat sink effect of blood flow inside large vessels protect the vessel wall from thermal damage during RF-assisted surgical resection?, Med. Phys., 2014, 41(8), DOI: 10.1118/1.4890103.
  • [8] GUO L., YU L., ZHAO Q., GONG X., XIE H., YUAN G., LI B., WAN X., Biodegradable jdbm coating stent has potential to be used in the treatment of benign biliary strictures, Biomed. Mater., 2021, 16(2), DOI: 10.1088/1748-605X/abda88.
  • [9] HOERMA,, H., SCHLEBUSCH H., Reversible and irreversible denaturation of collagen fibers, Biochemistry., 1971, 10, 932-937.
  • [10] HOLMER C., WINTER H., KRÖGER M., NAGEL A., JAENICKE A., LAUSTER R., KRAFT M., BUHR H.J., RITZ J.P., Bipolar radiofrequency-induced thermofusion of intestinal anastomoses-feasibility of a new anastomosis technique in porcine and rat colon, Langenbecks. Arch. Surg., 2011, 396, 529-533.
  • [11] HU Z., ZONG N., SONG C., ZHOU Y., TU L., MAO L., Intestinal tissue fusion based on radiofrequency energy, J. Med. Biomech., 2021, 36, 790-796 (in Chinese).
  • [12] KRAMER E.A., RENTSCHLER M.E., Energy-based tissue fusion for sutureless closure: applications, mechanisms, and potential for functional recovery, Annu. Rev. Biomed. Eng., 2018, 20, 1-20.
  • [13] MAHAPATRO A., MATOSNEGRO, T.D., GOMES A.S., Nanostructured self assembled monolayers on magnesium for improved biological performance, Mater. Technol., 2016, 31, 818-827.
  • [14] MAO L., ZHU H., CHEN L., ZHOU H., YUA, G., SONG C., Enhancement of corrosion resistance and biocompatibility of Mg-Nd-Zn-Zr alloy achieved with phosphate coating for vascular stent application, J. Mater. Res. Technol., 2020, 9, 6409-6419.
  • [15] PAN H., PAN F., WANG X., PENG J., GOU J., SHE J., TANG A., Correlation on the electrical and thermal conductivity for binary Mg-Al and Mg-Zn alloys, Int. J. Thermophys., 2013, 34, 1336-1346.
  • [16] PAWLIKOWSKI M., NIERODA A., Comparative analyses of blood flow through mechanical trileaflet and bileaflet aortic valves, Acta. Bioeng. Biomech., 2022, 24, 141-152.
  • [17] PEARCH J.A., Comparative analysis of mathematical models of cell death and thermal damage processes, Int. J. Hyperthermia., 2013, 29, 262-280.
  • [18] PENNES H.H., Analysis of tissue and arterial blood temperatures in the resting human forearm, J. Appl. Physiol., 1948, 1, 93-122.
  • [19] SMULDERS J.F., DEHINGH I., STAVAST J., JACKIMOWICZ J., Exploring new technologies to facilitate laparoscopic surgery: creating intestinal anastomoses without sutures or staples, using a radio-frequency-energy-driven bipolar fusion device, Surg. Endosc., 2007, 21, 2105-2109.
  • [20] SODERGRE, M., CLARK J., BEARDSLEY J., BRYA,T T., HORTOB K., DARZI A., TEARE J., A novel flexible endoluminal stapling device for use in NOTES colotomy closure: a feasibility study using an ex vivo porcine model, Surg. Endosc., 2011, 25, 3266-3272.
  • [21] SUNG H., FERLAY J., SIEGEL R.L., LAVERSANNE M., SOERJOMATARAM I., JEMAL A., BRAY F., Global cancer statistics 2020: Globocan estimates of incidence and mortality worldwide for 36 cancers in 185 countries, CA-Cancer. J. Clin., 2021, 71, 209-249.
  • [22] TRUJILLO M., BERJA,O E., Review of the mathematical functions used to model the temperature dependence of electrical and thermal conductivities of biological tissue in radiofrequency ablation, Int. J. Hyperthermia., 2013, 29, 590-597.
  • [23] TU L., ZHOU Y., SO,G C., LI Y., CHE, L., XUE Y., Preliminary study of a control algorithm for radiofrequency-induced intestinal tissue fusion, Int. J. Hyperthermia., 2019, 36, 1296-1305.
  • [24] TU L., ZHOU Y., WANG P., WANG H., MAO L., HOU J., LIU Z., SONG C., Minimizing thermal damage using self-cooling jaws for radiofrequency intestinal tissue fusion, Minim. Invasiv. Ther., 2023, 32, 33-41.
  • [25] WANG Q., YUAN H., GUO M., MENG L., LONG Z., LONG Y., YANG H., Threedimensional finite element analysis of a novel interzygapophyseal fusion device for lower cervical spine, Acta. Bioeng. Biomech., 2022, 24, 187-193.
  • [26] WANG Z., ZHU S., WANG L., CHANG L., WANG J., LI J., GUAN S., Preparing a novel magnesium-doped hyaluronan/polyethyleneimine nanoparticle to improve endothelial functionalisation, Iet. ,anobiotechnol., 2020, 14, 142-147.
  • [27] YAN S., WU X., WANG W., Theoretical and experimental analysis of amplitude control ablation and bipolar ablation in creating linear lesion and discrete lesions for treating atrial fibrillation, Int. J. Hyperther., 2017, 33, 608-616.
  • [28] ZANG L., ZHOU Y., KANG J., SONG C., Effect of the combination of different electrode spacings and power on bipolar radiofrequency fat dissolution: a computational and experimental study, Lasers. Surg. Med., 2020, 52, 1020-1031.
  • [29] ZHANG C., LIU H., TAN R., LI H., Interaction model between capsule robot and intestine based on nonlinear viscoelasticity, P. I. Mech. Eng. H., 2014, 228, 287-296.
  • [30] ZHAO L., SONG C., WANG Z., ZHOU Y., LI X., ZHU W., CUSCHIERI A., Novel concave–convex electrode for colonic anastomoses by radiofrequency thermo-fusion, Surg. Endosc., 2015, 29, 1809-1816.
  • [31] ZHOU H., HAN S., CHEN J., HUANG D., PENG L., NING J., LI Z., A feasibility study of closing the small bowel with high-frequency welding device, J. Biomedical. Eng., 2014, 31, 1332-1335 (in Chinese).
Uwagi
Brak numeracji stron
Opracowanie rekordu ze środków MNiSW, umowa nr SONP/SP/546092/2022 w ramach programu "Społeczna odpowiedzialność nauki" - moduł: Popularyzacja nauki i promocja sportu (2024).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-435f3390-c276-40dd-86fe-830246960bd8
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.