PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

The influence of environment on condition of location damage in screen of the coaxial cable

Autorzy
Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
This paper presents the results of laboratory tests of influence of the environment on pulses propagation conditions in the screen of coaxial cable. The reference level for the screen is the environment, which in real maintenance conditions, is the soil or it could be the inner work conductor. The objective of this work is to determine the possibility of using the pulse method for fault location of screen isolation of electric power cable line or telecommunication line. The special measurement system is described, which allows taking measurements of the influence of different substances types, which surround the location of damage, on the propagation of testing pulses. The results of measurements are shown in oscillograms obtained for typical substances which surround the cable in real exploitation conditions.
Rocznik
Tom
Strony
199--208
Opis fizyczny
Bibliogr. 8 poz., rys.
Twórcy
  • Opole University of Technology, 45-233 Opole, ul. Gen. Sosnkowskiego 31
Bibliografia
  • [1] Garbacz T., A. Tor: Effect of Porophor Content on the Useful Properties of External Coatings Of Cables Obtained by Foaming Extrusion (in Polish). Polimery, 4/2007, pp. 286-293.
  • [2] Kuwabara T., Koga H., T. Kitamura: Animal-resistant telecommunication cable sheath covered by a thin hard metal layer. Electron. Comm. Jpn. Pt. II, 70, 1987.
  • [3] Macphail A. and others: Third-Party Damage to Underground and Submarine Cables. CIGRE, Working Group B1.21, December 2009.
  • [4] Mashikian M. S, Szatkowski A.: Medium Voltage Cable Defects Revealed by Off-Line Partial Discharge Testing at Power Frequency. IEEE Electrical Insulation Magazine. July/August 2006, Vol. 22, No. 4, pp. 24-32.
  • [5] Szczerski R.: Location of cable faults and chosen problems of cable line exploitation (in polish). WNT, Warsaw 1999.
  • [6] Tarczyński W.: Pulse method measurements for determination of fault location. Archives of Electrical Engineering. Vol. LV, No 3-4, 2006, pp. 301-312.
  • [7] Vahlstrom W.: Strategies for Field Testing Medium Voltage Cable. IEEE Electrical Insulation Magazine. September/October 2009, Vol.25, No.5, pp. 7-17.
  • [8] Sheath fault location on power cables. Publication of SEBAKMT. 13-07-2010.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-4254db52-d9b8-46fe-a311-9148a536df45
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.