PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
Tytuł artykułu

The using of light field’s integral characteristic for estimation of daylight

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Wykorzystanie pól świetlnych do oceny warunków oświetlenia pomieszczeń światłem dziennym
Języki publikacji
EN
Abstrakty
EN
Light field is a physical notion that more precisely describes the light environment. Light comes to the point of view from all the sides. The situation depends on the point location in the space. For an extremely small point located in space, it is the medium spherical illumination that describes best of all the conditions of light environment. The physical meaning of spherical illumination is the integral of illumination on the infinitesimal sphere surface. It has symbol E4π that’s mean that light come to surface from all the sides.
PL
Pola świetlne stwarzają możliwości bardziej precyzyjnego opisywania środowiska świetlnego we wnętrzach budynków. Światło do danego punktu dociera z różnych kierunków, w związku z tym warunki oświetlenia zależą od położenia punktu w przestrzeni. W celu precyzyjnej oceny warunków świetlnych należy stosować przestrzenne charakterystyki oświetlenia, które można badać za pomocą luksomierza kulistego. Fizyczny sens oświetlenia sferycznego polega na oświetleniu powierzchni nieskończenie małej kuli. Parametr o symbolu E4π oznacza, że światło dociera do powierzchni ze wszystkich stron.
Rocznik
Tom
Strony
85--90
Opis fizyczny
Bibliogr. 9 poz., rys.
Twórcy
  • Moscow State University of Civil Engineering, Russia
  • Moscow State University of Civil Engineering, Russia
Bibliografia
  • 1. Soloviev A.K., The using of light field theory for the daylight interior illumination designing, Industrial and Civil Engineering 2010, 3, 40-41.
  • 2. Epaneshnikov M.M., Sydorova T.N., The estimation of the light saturation in the civil buildings, Light and Engineering, № 1, М.: 1965.
  • 3. Soloviev A.K., The scientific base of roof daylight system energy efficiency increase with using of the light field theory, Dissertation 2011.
  • 4. Muravyeva N.A., Soloviev A.K., About the perspective and the methods of the measurement of cylindrical illumination as a characteristic of the daylight environment in the room, Scientific Review 2014, 7-1, 62-68.
  • 5. Stetskii S.V., The creation of the comfort light environment in the room with vertical windows (on the example of the workplace of the designed organization). Dissertation 1979. (Moscow).
  • 6. Muravyeva N.А., The capability of the device RADIOLUX111 by Krochmann PRC.
  • 7. Objedkov V.A., Soloviev А.K., Laboratory practice in the physic of building.
  • 8. Onshyna A.S., Tschikota S.I., The estimation of the light field in the commercial moll with self-service system, Light and Engineering 2012, 4, 39-42.
  • 9. Stetskii S.V., Porublev S.A., Subjective estimation of light environment in the working location of small auto repairing companies for the climatic conditions of North Caucasia, Industrial and Civil Engineering 2011, 1, 46-48.
Uwagi
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-4152f41a-231a-4697-ad7b-4f1a0c845c1b
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.