Analysis of the accidental release of chlorine

Treść / Zawartość
Identyfikatory
Warianty tytułu
Konferencja
7th International Conference System Safety: Human - Technical Facility - Environment, CzOTO 2018 (7 ; 12-14.12.2018 ; Zakopane, Poland)
Języki publikacji
EN
Abstrakty
EN
Due to its properties, chlorine is one of the highly toxic substances used by humans. This gas attacks the respiratory system, eyes and skin. In higher concentrations, its inhalation leads to death. It is mainly used in water treatment plants where it guarantees a bacteriologically safe water in water supply systems. It is also used as a disinfectant and bleaching agent. The use, transport and storage of chlorine may pose serious hazard associated with its uncontrolled release from technological installations or tanks. The level of this threat will depend on the run of the release scenario or meteorological conditions. The article presents an analysis of the hazards associated with the uncontrolled release of chlorine. The ranges of zones with dangerous level of gas concentration are presented as a result of its instantaneous and continuous release.
Słowa kluczowe
Wydawca
Rocznik
Strony
149--155
Opis fizyczny
Bibliogr. 10 poz., rys., tab.
Twórcy
  • Istitute of Power Engineering and Turbomachinery, Silesian University of Technology, Poland
Bibliografia
  • [1] Brzozowska, L., Niesyto, M., 2018. Wpływ warunków meteorologicznych na skutki uwolnienia chloru w wyniku wypadku drogowego. Autobusy, 5, 62-67.
  • [2] Govier, P., Coulson, J.M., 2018. Civilian exposure to chlorine gas: A systematic review. Toxicology Letters, 293, 249-252.
  • [3] Khanmohamadi, M., Bagheria, M., Khademi, N., Ghannadpour, S.F., 2018. A security vulnerability analysis model for dangerous goods transportation by rail - Case study: Chlorine transportation in Texas-Illinois. Safety Science, 10, 230-241.
  • [4] Law, W.P., Erain, N., Ramli, N.I., Gimbun, J., 2019. Assessment of chlorine leak dispersion around Gebeng industrial area and potential evacuation route. Atmospheric Research, 117-129.
  • [5] Majder-Łopatka, M., Ciuka-Witrylak, M., Dmochowska, A., 2014. Analiza zagrożeń związanych z wykorzystaniem chloru w procesie uzdatniania wody. Logistyka, 5, 957-963.
  • [6] Scenne, N.J., Santa Cruz, A.S.M., 2005. Road risk analysis due to the transportation of chlorine in Rosario city. Reliability Engineering and Safety System, 462, 83-90.
  • [7] Sitarek, K., 2008. Chlor Dokumentacja dopuszczalnych wielkości narażenia zawodowego. Podstawy i Metody Oceny Środowiska Pracy, 1(55), 73-95.
  • [8] Ruj, B., Chatterjee, P.K., 2012. Toxic release of chlorine and off-site emergency scenario - A case study. Journal of Loss Prevention in the Process Industries, 25(3), 650-653.
  • [9] Węsierski T., Majder-Łoparka, M., 2012. Wykolejenie się wagonów kolejowych z chlorem w Białymstoku, Analiza zdarzenia i możliwych scenariuszy. Bezpieczeństwo i Technika Pożarnicza, 2, 71-80.
  • [10] Work Safe BC Publications, Chlorine Safe Work Practices. 2006.