The effect of process parameters of conversion coatings on the corrosion resistance was investigated. To produce anodic coatings, the solutions of H<sub>2</sub>SO<sub>4</sub> of 0.5 and 1 M concentrations and current densities of 0.5 and 1 A/dm<sup>2</sup> were applied. The coatings were deposited by galvanostatic technique on titanium Grade 1. The result of the study was comparison of the corrosion resistance of coatings produced under varying parameters such as: the anodic current density, the electrolyte concentration, and the speed of reaching the preset voltage. Corrosion tests performed by potentiodynamic polarization test have shown that even nanometric anodic films of amorphous structure improve the corrosion resistance of titanium alloy. The lowest corrosion current and the corrosion potential of the most cathodic nature were observed in the sample with anodic coating produced at J = 1 A/dm<sup>2</sup> in a 0.5 M H<sub>2</sub>SO<sub<4</sub> electrolyte concentration.
Wydawca
Czasopismo
Rocznik
Tom
Strony
205--208
Opis fizyczny
Bibliogr. 12 poz., rys., tab., wykr.
Twórcy
autor
- Institute of Non-Ferrous Metals in Gliwice, Light Metals Division in Skawina, 19 Piłsudskiego Str., 32-050 Skawina, Poland
autor
- Institute of Non-Ferrous Metals in Gliwice, Light Metals Division in Skawina, 19 Piłsudskiego Str., 32-050 Skawina, Poland
autor
- Institute of Non-Ferrous Metals in Gliwice, Light Metals Division in Skawina, 19 Piłsudskiego Str., 32-050 Skawina, Poland
autor
- Institute of Non-Ferrous Metals in Gliwice, Light Metals Division in Skawina, 19 Piłsudskiego Str., 32-050 Skawina, Poland
Bibliografia
- [1] G. Radegran, J. Lausmaa, L. Matsson et al. J. Elect. Micr. Tech. 19, 99 (1991).
- [2] T. Wierzchoń, E. Czarnowska, D. Krupa, Inżynieria powierzchni w wytwarzaniu biomateriałów tytanowych, Warszawa 2004.
- [3] J.-L. Deplancke, R. Winand, Electrochim. Acta 33, 1539 (1988).
- [4] J.-L. Deplancke, A. Garnier, Y. Massiani, R. Winand. Electrochim. Acta 39, 1281 (1994).
- [5] J. Lausmaa, B. Kasemo, H. Mattsson, H. Odelius, Appl. Surf. Sci. 45, 189 (1990).
- [6] V. Zwilling, Darque - Ceretii, A. Boutry - Forveille, D. David, et al., Surf. Interface Anal. 27 629 (1999).
- [7] C. Sitting, M. Textor, N.D. Spencer, M. Wieland, P-H. Vallotton. Mater. Med 10 35 (1999).
- [8] J.-L. Deplancke, M. Degraz, A. Fontana, R. Winand. Surf. Technol. 16 1533 (1982).
- [9] http://www.semos.dk
- [10] http://www.bibusmetals.pl
- [11] D. Velten, V. Biehl, F. Aubertin, B. Valeske, W. Possart, J. Breme. J. Biomed. Mater. Res. 59 18 (2002).
- [12] E. Krasicka - Cydzik, Formowanie cienkich warstw anodowych na tytanie i jego implantowych stopach w środowisku kwasu fosforowego, Zielona Góra 2003.
Uwagi
PL
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-3fe482f3-b0ba-4477-8fbd-d0786c9204ac