PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Evaluation of electrohysterogram measured from different gestational weeks for recognizing preterm delivery: a preliminary study using random Forest

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Developing a computational method for recognizing preterm delivery is important for timely diagnosis and treatment of preterm delivery. The main aim of this study was to evaluate electrohysterogram (EHG) signals recorded at different gestational weeks for recognizing the preterm delivery using random forest (RF). EHG signals from 300 pregnant women were divided into two groups depending on when the signals were recorded: i) preterm and term delivery with EHG recorded before the 26th week of gestation (denoted by PE and TE group), and ii) preterm and term delivery with EHG recorded during or after the 26th week of gestation (denoted by PL and TL group). 31 linear features and nonlinear features were derived from each EHG signal, and then compared comprehensively within PE and TE group, and PL and TL group. After employing the adaptive synthetic sampling approach and six-fold cross-validation, the accuracy (ACC), sensitivity, specificity and area under the curve (AUC) were applied to evaluate RF classification. For PL and TL group, RF achieved the ACC of 0.93, sensitivity of 0.89, specificity of 0.97, and AUC of 0.80. Similarly, their corresponding values were 0.92, 0.88, 0.96 and 0.88 for PE and TE group, indicating that RF could be used to recognize preterm delivery effectively with EHG signals recorded before the 26th week of gestation.
Twórcy
autor
  • College of Life Science and Bioengineering, Beijing University of Technology, Intelligent Physiological Measurement and Clinical Translation, Beijing International Platform for Scientific and Technological Cooperation, Beijing, China
autor
  • College of Life Science and Bioengineering, Beijing University of Technology, Intelligent Physiological Measurement and Clinical Translation, Beijing International Platform for Scientific and Technological Cooperation, Beijing, China
autor
  • College of Life Science and Bioengineering, Beijing University of Technology, Intelligent Physiological Measurement and Clinical Translation, Beijing International Platform for Scientific and Technological Cooperation, Beijing, China
autor
  • College of Life Science and Bioengineering, Beijing University of Technology, Intelligent Physiological Measurement and Clinical Translation, Beijing International Platform for Scientific and Technological Cooperation, Beijing, China
  • College of Life Science and Bioengineering, Beijing University of Technology, Intelligent Physiological Measurement and Clinical Translation, Beijing International Platform for Scientific and Technological Cooperation, Beijing, China
  • Beijing Haidian Maternal and Children Health Hospital, Beijing, China
autor
  • College of Life Science and Bioengineering, Beijing University of Technology, Intelligent Physiological Measurement and Clinical Translation, Beijing International Platform for Scientific and Technological Cooperation, Beijing, China
  • Centre for Intelligent Healthcare, Faculty of Health and Life Science, Coventry University, Coventry, UK
Bibliografia
  • [1] Wang ML, Dorer DJ, Fleming MP, Catlin EA. Clinical outcomes of near-term infants. Pediatrics 2004;114(2):372–6.
  • [2] de Lau H, Rabotti C, Oosterbaan HP, et al. Study protocol: PoPE-prediction of preterm delivery by electrohysterography. BMC Pregnancy Childbirth 2014;14 (1):192.
  • [3] Vinken MPGC, Rabotti C, Mischi M, Oei G. Accuracy of frequency-related parameters of the electrohysterogram for predicting preterm delivery a review of the literature. Obstet Gynecol Surv 2009;64(8):529–41.
  • [4] Sammali F, Kuijsters NPM, Schoot BC, et al. Feasibility of transabdominal Electrohysterography for analysis of uterine activity in nonpregnant women. Reprod Sci 2018;1–10.
  • [5] Alamedine D, Diab A, Muszynski C, Karlsson B, Khalil M, Marque C. Selection algorithm for parameters to characterize uterine EHG signals for the detection of preterm labor. Signal Image Video Process 2014;8(6):1169–78.
  • [6] Arora S, Garg G. A novel scheme to classify EHG signal for term and pre-term pregnancy analysis. Int J Comput Appl 2012;51(18):37–41.
  • [7] Diab MO, Marque C, Khalil MA. Classification for uterine EMG signals: comparison between AR model and statistical classification method. Int J Comput Cognit 2008;5(1):255–72.
  • [8] Naeem SM, Seddik AF, Eldosoky MA. New technique based on uterine electromyography nonlinearity for preterm delivery detection. J Eng Technol Res 2014;7(6):107–14.
  • [9] Smrdel A, Jager F. Separating sets of term and pre-term uterine EMG records. Physiol Meas 2015;36(2):341–55.
  • [10] Horoba K, Jezewski J, Matonia A. Early predicting a risk of preterm labour by analysis of antepartum electrohysterograhic signals. Biocybern Biomed Eng 2016;36 (4):574–83.
  • [11] Ahmed MU, Chanwimalueang T, Thayyil S, Mandic PD. A multivariate multiscale fuzzy entropy algorithm with application to uterine EMG complexity analysis. Entropy 2016;19(1). http://dx.doi.org/10.3390/e19010002.
  • [12] Alamedine D, Khalil M, Marque C. Parameters extraction and monitoring in uterine EMG signals. Detection of preterm deliveries. Innovation and Research in Biomedical engineering 2013;34(4-5):322–5.
  • [13] Hassan M, Terrien J, Alexandersson A. Nonlinearity of EHG signals used to distinguish active labor from normal pregnancy contractions. Annual international conference of the IEEE engineering in medicine and biology. 2010;2387–90.
  • [14] Lili C, Yaru H. Feature extraction and classification of EHG between pregnancy and labour group using Hilbert-Huang transform and extreme learning machine. Comput Math Methods Med 2017;2017:1–9.
  • [15] Alamedine D, Khalil M, Marque C. Comparison of different EHG feature selection methods for the detection of preterm labor. Comput Math Methods Med 2013;2013(4):585–93.
  • [16] Fergus P, Idowu I, Hussain A. Advanced artificial neural network classification for detecting preterm births using EHG records. Neurocomputing 2016;188(5):42–9.
  • [17] Ren P, Yao S, Li J. Improved prediction of preterm delivery using empirical mode decomposition analysis of uterine electromyography signals. PLoS One 2015;10(7):1–16.
  • [18] Fergus P, Cheung P, Hussain A. Prediction of preterm deliveries from EHG signals using machine learning. PLoS One 2013;8(10):e77154.
  • [19] Idowu I, Fergus P, Hussain A, et al. Artificial intelligence for detecting preterm uterine activity in gynacology and obstertric care. IEEE international conference on computer and information technology; ubiquitous computing and communications; dependable, autonomic and secure computing; pervasive intelligence and computing. 2015;215–20.
  • [20] Chen L, Hao Y, Hu X, et al. Detection of preterm birth in electrohysterogram signals based on wavelet transform and stacked sparse autoencoder. PLoS One 2019;14(4).
  • [21] Acharya UR, Sudarshan VK, Rong SQ. Automated detection of premature delivery using empirical mode and wavelet packet decomposition techniques with uterine electromyogram signals. Comput Biol Med 2017;85:33–42.
  • [22] Breiman L. Random forest. Mach Learn 2001;45(1):5–32.
  • [23] Fele-Žorž G, Kavšek G, Novak-Antolic Ž. A comparison of various linear and non linear signal processing techniques to separate uterine EMG records of term and pre-term delivery groups. Med Biol Eng Comput 2008;46(9):911–22.
  • [24] Devedeux D, Marque C, Mansour S, Germain G, Duchene J. Uterine electromyography: a critical review. Am J Obstet Gynecol 1993;169(6):1636–53.
  • [25] Verdenik I, Pajntar M, Leskosek B. Uterine electrical activity as predictor of preterm birth in women with preterm contractions. Eur J Obstet Gynecol Reprod Biol 2001;95 (2):149–53.
  • [26] Moslem B, Karlsson B, Diab MO. Classification performance of the frequency-related parameters derived from uterine EMG signals. Medicine and Biology Society 2011;3371–4.
  • [27] He H, Bai Y, Garcia EA, Li S. ADASYN: adaptive synthetic sampling approach for imbalanced learning. Proceedings 2008 international joint conference on neural networks (IJCNN); 2008;1322–8.
  • [28] Jager F, Libensek S, Gersak K, et al. Characterization and automatic classification of preterm and term uterine records. PLoS One 2018;13(8):e0202125.
  • [29] Hu X, Wang Z, Ren X. Classification of surface EMG signal using relative wavelet packet energy. Comput Methods Programs Biomed 2005;79(3):189–95.
  • [30] Ryu J, Park C. Time-frequency analysis of electrohysterogram for classification of term and preterm birth. Ieie Trans Smart Process Comput 2015;4(2):103–9.
  • [31] Alexandersson A, Steingrimsdottir T, Terrien J, et al. The Icelandic 16-electrode electrohysterogram database. Sci Data 2015;2150017.
  • [32] Lili C, Yaru H. Feature extraction and classification of EHG between pregnancy and labour group using Hilbert-Huang transform and extreme learning machine. Comput Math Methods Med 2017;2017:1–9.
  • [33] Mischi M, Chen C, Ignatenko T, et al. Dedicated entropy measures for early assessment of pregnancy progression from single-channel electrohysterography. IEEE Trans Biomed Eng 2018;65(4):875–84.
  • [34] Carola H, Sherif AS, Rodrigo R. Potential use of electrohysterography in obstetrics: a review article. J Matern Neonatal Med 2019. http://dx.doi.org/10.1080/14767058.2019.1639663.
  • [35] Dongmei H, Jin P, Ying W, et al. Evaluation of convolutional neural network for recognizing uterine contractions with electrohysterogram. Comput Biol Med 2019;2019 (113):103394.
  • [36] Jin P, Dongmei H, Haipeng L, et al. Preliminary study on the efficient electrohysterogram segments for recognizing uterine contractions with convolutional neural networks. Biomed Res Int 2019. http://dx.doi.org/10.1155/2019/3168541.
  • [37] Dongmei H, Qian Q, Xiya Z, et al. Application of decision tree in determining the importance of surface electrohysterography signal characteristics for recognizing uterine contractions. Biocybern Biomed Eng 2019;39(3).
  • [38] Dongmei H, Yang A, Xiangyun Q, et al. Development of electrohysterogram recording system for monitoring uterine contraction. J Healthc Eng 2019;2019(1):1–9.
  • [39] Lucovnik M, Maner WL, Chambliss LR, et al. Noninvasive uterine electromyography for prediction of preterm delivery. Am J Obstet Gynecol 2011;204(3):228–38.
Uwagi
PL
Opracowanie rekordu ze środków MNiSW, umowa Nr 461252 w ramach programu "Społeczna odpowiedzialność nauki" - moduł: Popularyzacja nauki i promocja sportu (2020).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-3f114407-5af0-4abb-939e-32679d5e2a3c
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.