PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Heat exchange model in adsorbers of sorption refrigeration units

Autorzy
Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Model wymiany ciepła w adsorberach sorpcyjnych urządzeń chłodniczych
Języki publikacji
EN
Abstrakty
EN
One of the specific components of the construction of refrigeration equipment are adsorbers whose main task is to replace the compressors located in typical refrigeration plants. In contrast to adsorbers used in other industries for the purification of gases or liquids, in the case of refrigeration applications, also the process of heat exchange is very important in addition to the sorption/desorption process. This paper proposes a heat exchange model in the adsorbers used in refrigeration equipment. The model has been verified experimentally. As a result of experimental research, the average discrepancy of results at the level of 7.4 K was obtained.
PL
Jednym ze specyficznych elementów budowy urządzeń chłodniczych są adsorbery, których głównym zadaniem jest zastąpienie sprężarek znajdujących się w typowych instalacjach chłodniczych. W przeciwieństwie do adsorberów stosowanych w innych gałęziach przemysłu do oczyszczania gazów lub cieczy, w przypadku zastosowań chłodniczych oprócz procesu sorpcji/desorpcji bardzo istotny jest proces wymiany ciepła. W niniejszej pracy zaproponowano model wymiany ciepła w adsorberach urządzeń chłodniczych oraz zweryfikowano go eksperymentalnie. W wyniku badań eksperymentalnych udało się uzyskać średnią rozbieżność wyników na poziomie 7,4 K.
Rocznik
Strony
91--98
Opis fizyczny
Bibliogr. 18 poz., rys., tab., wykr.
Twórcy
  • Instytut Techniki Cieplnej, Wydział Mechaniczny Energetyki i Lotnictwa, Politechnika Warszawska
Bibliografia
  • [1] Cacciola G., Restuccia G., Reversible adsorption heat pump: a thermodynamic model, Int. J. Refrig. 18 (1995) 100-106.
  • [2] Chorowski M., Pyrka P., Modelling and experimental investigation of an adsorption chiller using low-temperature heat from cogeneration, Energy. 92 (2015) 221-229.
  • [3] Chwieduk D. A., Towards modern options of energy conservation in buildings, Renew. Energy. 101 (2017) 1194-1202.
  • [4] Cyklis P., Janisz K., An innovative ecological hybrid refrigeration cycle for high power refrigeration facility, Chem. Process Eng. – Inż. Chem. i Proces. 36 (2015) 321-330.
  • [5] Grzebielec A., Termodynamiczne podstawy przenoszenia ciepła w termoakustycznych urządzeniach chłodniczych, Chłodnictwo. 44 (2009) 12-16.
  • [6] Grzebielec A. , Szelągowski A., Use of the water-silicagel sorption set in a refrigeration unit, Przem. Chem. 7 (2017) 106-114.
  • [7] Jaworski M., Bednarczyk M., Czachor M., Experimental investigation of thermoelectric generator (TEG) with PCM module, Appl. Therm. Eng. 96 (2016), 527-533.
  • [8] Jędrzejuk H., Rucińska J., Verifying a need of artificial cooling – A simplified method dedicated to single-family houses in Poland, in: Energy Procedia, 2015.
  • [9] Kajurek J., Rusowicz A., Grzebielec A., Bujalski W., Futyma K., Szczęśniak A., Rudowicz Z., Influence of working fluid properties on performance of organic Rankine cycle, Rynek Energii. (2017) 68-79.
  • [10] Kupiec K., Rakoczy J., Komorowicz T., Larwa B., Heat and mass transfer in adsorption-desorption cyclic process for ethanol dehydration, Chem. Eng. J. 241 (2014) 485-494.
  • [11] Kwiatkowski T., Prusiński P., Zgorzelski D., Kozioł S., Instability issues in the server room cooling system, J. Power Technol. 97 (2017) 252-258.
  • [12] Qu T. F., Wang R. Z., Wang W., Study on heat and mass recovery in adsorption refrigeration cycles, Appl. Therm. Eng. 21 (2001) 439-452.
  • [13] Rusowicz A., Grzebielec A., Overview of Large Scale Solar cooling systems, Chłodnictwo. 6 (2014) 16-19.
  • [14] Sikora M., Bohdal T., Modeling of Pressure Drop during Refrigerant Condensation in Pipe Minichannels, Arch. Thermodyn. 38 (2017) 15-28.
  • [15] Srivastava N. C., Eames I. W., A review of adsorbents and adsorbates in solid-vapour adsorption heat pump systems, Appl. Therm. Eng. 18 (1998) 707-714.
  • [16] Taylan O., Baker D. K., Kaftanoǧlu B., COP trends for ideal thermal wave adsorption cooling cycles with enhancements, Int. J. Refrig. 35 (2012) 562-570.
  • [17] Trela M., Kwidzinski R., Butrymowicz D., Karwacki J., Exergy analysis of two-phase steam-water injector, Appl. Therm. Eng. 30 (2010) 340-346.
  • [18] Wang L. W., Wang R. Z., Oliveira R. G., A review on adsorption working pairs for refrigeration, Renew. Sustain. Energy Rev. 13 (2009) 518-534.
Uwagi
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2018).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-3ed518de-1b31-4ca9-b4f2-3ff3c3bf3057
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.