Evaluation of contact characteristics of a patient-specific artificial dysplastic hip joint

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
This study addresses the results of the experimental measurements for the contact surface areas and contact pressure distributions of a dysplastic hip joint. The hip joint consists of pelvis, proximal femur and artificial cartilages for both acetabulum and femoral head. The dysplastic hip joint is modeled in three dimensional (3D) form using the computerized tomography (CT) images obtained in vivo of an adult female patient. The modeled hip joint components are manufactured as a non-natural dysplastic hip joint using different materials and manufacturing processes. The dysplastic hip joint produced is subjected to compression forces experimentally to measure the contact surface area and contact pressure distributions between the femoral head and acetabulum using the pressure sensitive Fuji film. Different types of specific fixtures and molds are designed and manufactured to produce the dysplastic hip joint components and perform the experimental studies. The measured results using a non-natural dysplastic hip joint are compared with relevant results reported in current literature considering the peak and mean contact pressure values. Therefore, the obtained results showed that the non-natural dysplastic hip models can be generated and replaced to determine the contact characteristics for an elusive cadaveric model. In conclusion, the artificial models might be useful to understand the contact pressure distributions and potential changes in surface pressure contours and their effects on the stress distributions.
Słowa kluczowe
Rocznik
Strony
111--120
Opis fizyczny
Bibliogr. 42 poz., rys., wykr.
Twórcy
autor
  • Department of Biomedical Engineering, Kocaeli University, Kocaeli, Turkey
autor
  • Department of Automotive, Technical Science Vocational School, Amasya University, Amasya, Turkey
autor
  • Department of Biomedical Engineering, Kocaeli University, Kocaeli, Turkey
autor
  • Department of Orthopaedics and Traumatology, Kocaeli University, Kocaeli, Turkey
  • Department of Orthopaedics and Traumatology, Kocaeli University, Kocaeli, Turkey
autor
  • Department of Biomedical Engineering, Kocaeli University, Kocaeli, Turkey
Bibliografia
  • [1] WIBERG G., Studies on Dysplastic Acetabula and Congenital Subluxation of the Hip Joint, Acta Chir. Scand., 1939, 5, 135.
  • [2] LEGAL H., Introduction to the biomechanics of the hip, Springer-Verlag, Berlin, 1987.
  • [3] GENDA E., IWASAKI N., LI G., MACWILLIAMS B.A., BARRANCE P.J., CHAO E.Y., Normal hip joint contact pressure distribution in single-leg standing-effect of gender and anatomic parameters, J. Biomech. 2001, 34, 895–905.
  • [4] IGLIC A., KRALJ-IGLIC V., DANIEL M., MACEK-LEBAR A., Computer determination of contact stress distribution and size of weight bearing area in the human hip joint, Comput. Meth. Biomech. Biomed. Eng., 2002, 5, 185–192.
  • [5] MAVCIC B., POMPE B., ANTOLIC V., DANIEL M., IGLIC A., KRALJ-IGLIC V., Mathematical estimation of stress distribution in normal and dysplastic human hips, J. Orthop. Res., 2002, 20, 1025–1030.
  • [6] XU L., SU Y., KIENLE K.-P., HAYASHI D., GUERMAZI A., ZHANG J. et al., Evaluation of radial distribution of cartilage degeneration and necessity of pre-contrast measurements using radial dGEMRIC in adults with acetabular dysplasia, BMC Musculoskelet Disord., 2012, 13, 212.
  • [7] BRAND R.A., Joint contact stress: A reasonable surrogate for biological processes? Iowa Orthop. J. 2005, 25, 82.
  • [8] WIERZCHOLSKI K., Stochastic impulsive pressure calculations for time dependent human hip joint lubrication, Acta Bioeng. Biomech., 2012, 14, 81–100.
  • [9] AFOKE N.Y., BYERS P.D., HUTTON W.C., Contact pressures in the human hip joint, J. Bone Joint Surg. Br., 1987, 69, 536–541.
  • [10] SPARKS D.R., BEASON D.P., ETHERIDGE B.S., ALONSO J.E., EBERHARDT A.W., Contact pressures in the flexed hip joint during lateral trochanteric loading, J. Orthop. Res., 2005, 23, 359–366.
  • [11] VON EISENHART R., ADAM C., STEINLECHNER M., MÜLLERGERBL M., ECKSTEIN F., Quantitative determination of joint incongruity and pressure distribution during simulated gait and cartilage thickness in the human hip joint, J. Orthop. Res., 1999, 17, 532–539.
  • [12] MICHAELI D.A., MURPHY S.B., HIPP J.A., Comparison of predicted and measured contact pressures in normal and dysplastic hips, Med. Eng. Phys., 1997, 19, 180–186.
  • [13] PRESSEL T., MAX S., PFEIFER R., OSTERMEIER S., WINDHAGEN H., HURSCHLER C., A rapid prototyping model for biomechanical evaluation of pelvic osteotomies, Biomed. Tech. (Berl)., 2008, 53, 65–69.
  • [14] ZANETTI E.M., BIGNARDI C., AUDENINO A.L., Human pelvis loading rig for static and dynamic stress analysis, Acta Bioeng. Biomech., 2012, 14, 61–66.
  • [15] JOHNSON E., YOUNG P., On the use of a patient-specific rapid-prototyped model to simulate the response of the human head to impact and comparison with analytical and finite element models, J. Biomech., 2005, 38, 39–45.
  • [16] DOBSON C.A., SISIAS G., PHILLIPS R., FAGAN M.J., LANGTON C.M., Three dimensional stereolithography models of cancellous bone structures from *mCT data: testing and validation of finite element results, Proc. Inst. Mech. Eng. H, J. Eng. Med., 2006, 220, 481–484.
  • [17] DHAKSHYANI R., NUKMAN Y., AZUAN A.O.N., FDM models and FEA in dysplastic hip, Rapid Prototyping J., 2012, 18, 215–221.
  • [18] PLOMINSKI J., WATRAL Z., KWIATKOWSKI K., Testing the stability of the polyethylene acetabulum cemented on a frozen Acta Bioeng. Biomech., 2008, 10, 3–6.
  • [19] ANDERSON A.E., ELLIS B.J., MAAS S.A., PETERS C.L., WEISS J.A., Validation of finite element predictions of cartilage contact pressure in the human hip joint, J. Biomech. Eng., 2008, 130, 051008.
  • [20] DHAKSHYANI R., NUKMAN Y., OSMAN N.A., MERICAN A., GEORGE J., Rapid prototyping medical models for dysplastic hip orthopaedic surgery, Proc. Inst. Mech. Eng. H, J. Eng. Man., 2010, 224, 769–776.
  • [21] Task-9. SMOOTH-ON, Inc. PA, USA.
  • [22] RUSSELL M.E., SHIVANNA K.H., GROSLAND N.M., PEDERSEN D.R., Cartilage Contact Pressure Elevations in Dysplastic Hips: A Chronic Overload Model, J. Orthop. Surg. Res., 2006, 1, 6.
  • [23] ANDERSON D.D., GOLDSWORTHY J.K., LI W., JAMES RUDERT M., TOCHIGI Y., BROWN T.D., Physical validation of a patientspecific contact finite element model of the ankle, J. Biomech., 2007, 40, 1662–1669.
  • [24] CHEGINI S., BECK M., FERGUSON S.J., The effects of impingement and dysplasia on stress distributions in the hip joint during sitting and walking: a finite element analysis, J. Orthop. Res., 2009, 27, 195–201.
  • [25] HARRIS M.D., ANDERSON A.E., HENAK C.R., ELLIS B.J., PETERS C.L., WEISS J.A., Finite element prediction of cartilage contact stresses in normal human hips, J. Orthop. Res., 2012, 30, 1133–1139.
  • [26] Aluminum 5083 material properties, http://www.ozon.com/ article.aspx?ArticleID=2804.2012. Ref. Type: Internet Communication.
  • [27] DALSTRA M., VAN ERNING L., HUISKES R., Development and Validation of a Three-Dimensional Finite Element Model of the Pelvic Bone, J. Biomech. Eng., 1995, 117, 272–278.
  • [28] LIGGINS A.B., STRANART J.C.E., FINLAY J.B., RORABECK C.H., Calibration and Manipulation of Data from Fuji Pressure-Sensitive Film, Clin. Asp. B, 1992, 3, 61–70.
  • [29] BACHUS K.N., DEMARCO A.L., JUDD K.T., HORWITZ D.S., BRODKE D.S., Measuring contact area, force, and pressure for bioengineering applications: Using Fuji Film and Tek-Scan systems, Med. Eng. Phys., 2006, 28, 483–488.
  • [30] HADLEY N.A., BROWN T.D., WEINSTEIN S.L., The effects of contact pressure elevations and aseptic necrosis on the longterm outcome of congenital hip dislocation, J. Orthop. Res., 1990, 8, 504–513.
  • [31] KRALJ-IGLIC V., DOLINAR D., IVANOVSKI M., LIST I., DANIEL M., MAVCIC B. et al., Hip stress distribution may be a risk factor for avascular necrosis of femoral head, [in:] T. Jarm, P. Kramar, A. Zupanic (eds.), 11th Mediterranean Conference on Medical and Biomedical Engineering and Computing, Springer, Berlin, Heidelberg, 2007, 282–285.
  • [32] HUISKES R., RONALD R., HARRY V.L.G., D. JJ. Effects of mechanical forces on maintenance and adaptation of form in trabecular bone, Nature, 2000, 405, 704.
  • [33] OLSON S., BAY B., CHAPMAN M., SHARKEY N., Biomechanical consequences of fracture and repair of the posterior wall, The Journal of bone and joint surgery, 1995, 77, 1184–1192.
  • [34] VON EISENHART-ROTHE R., ECKSTEIN F., MÜLLER-GERBL M., LANDGRAF J., ROCK C., PUTZ R., Direct comparison of contact areas, contact stress and subchondral mineralization in human hip joint specimens, Anatomy and embryology, 1997, 195, 279–288.
  • [35] AFOKE N., BYERS P., HUTTON W., Tests on hypotheses about osteoarthritis and hip joints, Ann. Rheum. Dis., 1992, 51, 485–488.
  • [36] KONRATH G.A., HAMEL A.J., GUERIN J., OLSON S.A., BAY B., SHARKEY N.A., Biomechanical evaluation of impaction fractures of the femoral head, J. Orthop. Trauma., 1999, 13, 407–413.
  • [37] BACHTAR F., CHEN X., HISADA T., Finite element contact analysis of the hip joint, Med. Bio. Eng. Comput., 2006, 44, 643–651.
  • [38] ILIESCU N., DAN PASTRAMA S., GRUIONU L.G., JIGA G., Biomechanical changes of hip joint following different types of corrective osteotomy – photoelastic studies. Acta Bioeng. Biomech., 2008, 10, 65–71.
  • [39] Fuji Photo Film Co. Ltd. Pressure measuring film-FUJI prescale film instruction manual.
  • [40] MURIUKI M.G., GILBERTSON L.G., HARNER C.D., Characterization of the performance of a custom program for image processing of pressure sensitive film, J. Biomech. Eng., 2009, 131, 14503.
  • [41] LIAU J.-J., HU C.-C., CHENG C.-K., HUANG C.-H., LO W.-H., The influence of inserting a Fuji pressure sensitive film between the tibiofemoral joint of knee prosthesis on actual contact characteristics, Clin. Biomech., 2001, 16, 160–166.
  • [42] LIGGINS A., SURRY K., FINLAY J., Sealing Fuji Prescale pressure sensitive film for protection against fluid damage: the effect on its response, Strain, 1995, 31, 57–62.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-3db26e77-fadf-4b40-91c7-bcd1814cc78f
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.