PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Tribological properties of Stellite 6 cobalt alloy implanted with nitrogen ions determined in the tests conducted in engine fuel atmosphere

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The influence of nitrogen ion implantation on the tribological properties of Stellite 6 cobalt alloy was investigated. The tribological tests were conducted using a pin / ball on disc in the atmosphere of engine fuels. In the study, cobalt alloy was implanted with 60 keV nitrogen ions at the fluence of 1∙1016 and 5∙1016 N+/cm2. The wear trace was measured using the Form Talysurf Intra Taylor Hobson profilometer. The results demonstrate that nitrogen ion implantation affects the friction coefficient and wear. The effect of nitrogen ion implantation depends on the environment in which the tribological test is carried out, the sample temperature and the presence of friction products in the friction node.
Słowa kluczowe
Twórcy
autor
  • Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland
  • Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland
Bibliografia
  • 1.Abreu C.M., Cristobal M.J., Figueroa R., Pena G.: Wear and corrosion performance of two different tempers (T6 and T73) of AA7075 aluminum alloy after nitrogen implantation, 2015, 327, 51–61.
  • 2.Adamiec P., Dziubiński J.: Wybrane zagadnienia materiałów kontrukcyjnych i technologii wytwarzania pojazdów. WPŚ, Gliwice 1998.
  • 3.Adamiec P., Dziubiński J.: Wytwarzanie i właściwości warstw wierzchnich elementów maszyn transportowych. WPŚ, Gliwice 2005.
  • 4.Budzyński P.: Problematyka tarcia i zużycia tworzyw implantowanych jonowo w technologii maszyn. WPL, Lublin 2010.
  • 5.Budzyński P., Kamiński M., Pałka K., Droździel A., Wiertel M.: The influence of nitrogen ion implantation on microhardness of the Stellite 6 alloy. IOP Conf. Series: Materials Science and Engineering 2016, 148, 012046.
  • 6.Budzyński P., Kamiński M., Pyszniak K.: The influence of nitrogen ion implantation on the tribological properties of piston rings made of Hardox and Raex steels. IOP Conf. Series: Materials Science and Engineering, 2016, 148, 012044.
  • 7.Budzyński P., Kamiński M., Wiertel M., Pyszniak K., Droździel A.: Mechanical properties of Stellite 6 cobalt alloy implanted with nitrogen ions. XI-th International Conference Ion Implantation and Other Applications of Ions and Electrons (ION 2016). 2016, 45.
  • 8.Budzyński P., Kara L., Küçükömeroğlu T., Kamiński M.: The influence of nitrogen implantation on tribological properties of AISI H11 steel. Vacuum, 2015, 122, 230–235.
  • 9.Budzyński P., Tarkowski P., Penkała P.: Influence of nitrogen ion implantation on tribological properties of tool steel NC10. Vacuum, 2001, 63, 731–736
  • 10.Burakowski T., Wierzchoń T.: Inżynieria powierzchni metali. WNT, Warszawa 1995.
  • 11.Cristobal M.J., Figueroa R., Mera L., Pena G.: Tribological behavior of aluminum alloy AA7075 after ion implantation, Surface Coatings and Technology, 2012, 209, 124–130.
  • 12.Guo Z., Pang X., Yan Y., Gao K., Volinsky A. A., Zhang T. Y.: CoCrMo alloy for orthopedic Implant application enhanced corrosion and tribocorrosion properties by nitrogen ion implantation. Applied surface science. 2015, 347, 23–34.
  • 13.Lewis R., Dwyer-Joyce R. S.: Wear of diesel engine inlet valves and seat inserts Proceedings of the Institution of Mechanical Engineers, Part D: Journal of Automobile Engineering, 2002, 216, 205–16
  • 14.McCafferty E.: Effect of Ion Implantation on the corrosion behavior of iron, Stainless steels, and aluminum – a review, Corrosion, 2001, 57, 471–476.
  • 15.Moćko W.: Analiza wytężenia zaworu silnikowego wykonanego ze stopu tytanu Ti6AL4V obciążonego mechanicznie i cieplnie Transport samochodowy, 2014, 4, 55–71.
  • 16.Picard S., Memet J. B., Sabot R., Grosseau-Poussard J.L., Rivière J. P., Meilland R.: Corrosion behaviour, microhardness and surface characterisation of low energy, high current on implanted austenitic stainless steel. Mater. Sci. Engin., 2001, 303, 163–72.
  • 17.Wajand J. A., Wajand J. T.: 2005 Tłokowe silniki spalinowe średnio- i szybkoobrotowe. WNT, Warszawa, 2005.
  • 18.Wang F., Zhou Ch., Zheng L., Zhang H.: Corrosion resistance of carbon ion-implanted M50 NiL aerospace bearinh steel. Progress in Natural Science: Materials International, 2017, 27, 615–621.
  • 19.Vlcak P., Cerny F., Drahokoupil J., Sepitka J., Tolbe Z.: The microhardness ond surface hardness of Ti6Al4V alloy implanted with nitrogen ions at an elevated temperature, 2015, 620, 48–54.
  • 20.Zhang J., Peng S., Zhang A. et al.: Nitrogen ion implantation on the mechanical properties of AISI 420 martensitic stainless steel. Surface and Coating Technology, 2016, 305, 132–138.
  • 21.Ziegler J. F.: SRIM-2003 steel Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms. 2004, 219–220, 1027–36.
Uwagi
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę (zadania 2017)
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-3d262d33-5040-45b3-b615-19bd237d31b2
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.