PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
Tytuł artykułu

Comparison of three estimators used in a sensorless MPPT strategy for a wind energy conversion chain based on a PMSG

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Porównanie trzech estymatorów wykorzystywanych w strategii śledzenia maksimum mocy MPPT w generatorze synchronicznym z magnesami trwałymi PMSG
Języki publikacji
EN
Abstrakty
EN
In this paper a WECS (Wind Energy Conversion System) based on a PMSG (Permanent Magnet Synchronous Generator) and implementing a sensorless MPPT (Maximum Power Point Tracking ) strategy is presented using three types of generator rotor speed and angle estimators; the Angle Tracking Observer, the Extended Kalman Filter and the Synchronous Reference Frame Phase Locked Loop. The main purpose is to compare these estimators. Simulation results in Matlab-Simulink allowing this comparison can be found at the end of this work.
PL
W artykule opisano generator z magnesami stałymi PMSG wykorzystujący strategię MPPT (śledzenie maksimum mocy). Porównano trzy typy estymatorów prędkości i kąta obrotu wirnika: czujnik kąta obrotu (angle tracking observer), filtr Kalmana i synchroniczną pętlę fazową (synchronous frame phase locked loop).
Rocznik
Strony
18--22
Opis fizyczny
Bibliogr. 8 poz., rys., tab., wykr.
Twórcy
  • Department of Electrical engineering, ENSET Rabat, Mohammed V University, Rabat, Morocco
autor
  • Department of Electrical engineering, ENSET Rabat, Mohammed V University, Rabat, Morocco
autor
  • National Center for Scientific and Technical Research, Rabat, Morocco
Bibliografia
  • [1] Polinder H., van der Pijl F. F. A., De Vilder G. J., Tavner P. J.: Comparison of direct-drive and geared generator concepts for wind turbines, IEEE Trans. Energy Conversion, vol. 21, no. 3, pp. 725–733, Sep. 2006.
  • [2] Yan Y., Wang S., Xia C., Wang H., Shi T. : Hybrid Control Set- Model Predictive Control for Field-Oriented Control of VSIPMSM, IEEE Transactions on Energy Conversion, Volume: 31, Issue: 4, Dec. 2016.
  • [3] Tan Y., Moase W., Manzie C., Nesic D., Mareels I. : Extremum seeking from 1922 to 2010, Proc.of the 29th Chinese Control Conference, pp. 14-26. 2010.
  • [4] Auger F., Mansouri-Toudert O., Chibah A.: Design of advanced resolver-to-digital converters, proc. Electrimacs conf., 2011.
  • [5] Gowda M., Ali W. h., Cofie P., Fuller J. : Design and Digital Implementation of Controller for PMSM Using Extended Kalman Filter, Circuits and Systems, 4, pp. 489-497, Published Online Dec. 2013.
  • [6] Gonzlez-Esp F., FiguereS E., Garcer G.: An Adaptive Synchronous-Reference-Frame Phase-Locked Loop for Power Quality Improvement in a Polluted Utility Grid, IEEE Transactions on Industrial Electronics, Volume: 59 , Issue: 6, pp. 2718-2731. 2012.
  • [7] Infield D., Freris L. : Les energies renouvelables pour la production d’electricite, Techniques et Ingenierie, Dunod/Dunod lusine nouvelle, 2013.
  • [8] Bhende C. N., Mishra S.,Senior Member, IEEE, Malla S. G.: Permanent Magnet Synchronous Generator-Based Standalone Wind Energy Supply System, IEEE Tansactions on Sustainable Energy, vol. 2, no. 4, pp. 361–373, October. 2011.
Uwagi
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2018).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-37dba454-4a6c-4439-a34d-5f7646901839
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.