Electrostatic precharger/agglomerator based on AC electric field charging principle is presented in this paper. The device is formed by a set of two discharge electrodes separated by a set of two parallel grids placed at both sides of each discharge electrode. The particles are charged by ionic current emitted by the discharge electrodes and flow in transversal alternating electric field generated by the grids. Because of oscillatory motion of the particles, particles of different mobilities can collide and coagulate. Number collection efficiency of PM2.5 particles was higher than 93%.
PL
W artykule przedstawiono elektryzator/aglomerator zbudowany na bazie elektryzatora przemiennonapięciowego. Urządzenie składa się z dwóch zestawów elektrod wyładowczych oddzielonych dwiema równoległymi siatkami umieszczonymi po obu stronach elektrod wyładowczych. Przepływające cząstki są ładowane prądem jonowym emitowanym z elektrod wyładowczych w poprzecznym zmiennym polu elektrycznym. Cząstki poruszające się ruchem oscylacyjnym zderzają się i koagulują. Skuteczność oczyszczania cząstek PM 2.5 jest większa od 93%
Rocznik
Strony
237--241
Opis fizyczny
Bibliogr. 9 poz., fot., rys., tab., wykr.
Twórcy
autor
  • Institute of Fluid Flow Machinery, Polish Academy of Sciences, Fiszera 14, 80-231 Gdańsk, Poland
autor
  • Institute of Fluid Flow Machinery, Polish Academy of Sciences, Fiszera 14, 80-231 Gdańsk, Poland
  • Institute of Fluid Flow Machinery, Polish Academy of Sciences, Fiszera 14, 80-231 Gdańsk, Poland
  • Institute of Fluid Flow Machinery, Polish Academy of Sciences, Fiszera 14, 80-231 Gdańsk, Poland
autor
  • Institute of Fluid Flow Machinery, Polish Academy of Sciences, Fiszera 14, 80-231 Gdańsk, Poland
autor
  • RAFAKO S.A., ESP Division, Górnośląska 3A, 43-200 Pszczyna, Poland
  • RAFAKO S.A., ESP Division, Górnośląska 3A, 43-200 Pszczyna, Poland
autor
  • RAFAKO S.A., ESP Division, Górnośląska 3A, 43-200 Pszczyna, Poland
autor
  • RAFAKO S.A., ESP Division, Górnośląska 3A, 43-200 Pszczyna, Poland
autor
  • Gdynia Maritime University, Faculty of Mechanics, ul. Morska 81-87, 81-225 Gdynia, Poland
Bibliografia
  • [1] McCain J.D., Gooch J.P., Smith W.B., Results of field measurements of industrial participate sources and electrostatic precipitator performance, Journal of the Air Pollution Control Association 25 (1975), No.2, 117-121
  • [2] Mizuno A., Electrostatic precipitation. IEEE Trans. Dielectr. Electr. Insul. 7 (2000), No.5, 615-624
  • [3] White H J, J. Resistivity problems in electrostatic precipitation, Air Poll. Contr. Assoc. 24 (1974), No.4, 314-338
  • [4] Masuda S, Washizu M, Ionic charging of a very high resistivity spherical particle, J. Electrostatics 6 (1979), No.1, 57-67
  • [5] Masuda S., Hosokawa Sh., Performance of two-stage type electrostatic precipitators, IEEE Ind. Appl. Soc. Conf. Rec. (1982), 1094-1101
  • [6] McLean KJ, Electrostatic precipitators, IEE Rev. 135 (1988), Pt.A, No.6, 347-361
  • [7] Jaworek A, Krupa A, Adamiak K., Dust particles removal in novel type two-stage electrostatic precipitator Inst. Phys. Conf. Ser. No.178 (2003) Edinburgh, 343-348
  • [8] Lin W.Y., Chang Y.Y., Lien C.T., Kuo C.W., Separation characteristics of submicron particles in an electrostatic precipitator with alternating electric field corona charger, Aerosol Sci. Technol. 45 (2011),:393-400
  • [9] Jaworek A., Krupa A., Airborne Particle Charging by Unipolar Ions in AC Electric Field, J. Electrostatics 23 (1989), 361-370