PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Corrosion behaviour of polished and sandblasted titanium alloys in PBS solution

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
In this work, we performed comparative studies of the effect of surface preparation of Ti6Al4V and Ti6Al7Nb biomedical alloys and the influence of endothelial cells on their corrosion behaviour in PBS (Phosphate Buffered Saline). Two different methods of surface modification were applied – polishing and sandblasting. The polished Ti6Al7Nb alloy was found to have the best resistance against general corrosion in PBS. It was characterized by the lowest corrosion rate, the widest passive range and the lowest reactivity. Both alloys prepared by sandblasting exhibited worse corrosion properties in comparison to the polished ones. This can be associated with a greater development of their surface and the presence of Al2O3 grains which caused an increase of corrosion potential but might also influence the weakening of the passive layer. Results of potentiodynamic anodic polarization indicated that more resistant to pitting corrosion was Ti6Al7Nb alloy regardless of the method of surface preparation. In those cases, anodic polarization caused only an increase of passive layer, while in the case of sandblasted Ti6Al4V alloy it caused a pitting corrosion. The results obtained allowed us to conclude that the niobium-titanium alloys had higher corrosion resistance than titanium alloys with vanadium. Moreover, it was stated that endothelial cells improved the corrosion resistance of all the titanium alloys examined.
Rocznik
Strony
87--94
Opis fizyczny
Bibliogr. 29 poz., rys., tab., wykr.
Twórcy
autor
  • University of Łódź, Department of Inorganic and Analytical Chemistry, Łódź, Poland
  • Łódź University of Technology, Department of Materials’ Research, Łódź, Poland
  • University of Łódź, Department of Inorganic and Analytical Chemistry, Łódź, Poland
autor
  • Łódź University of Technology, Department of Materials’ Research, Łódź, Poland
  • Medical University of Łódź, Department of Dental Techniques, Łódź, Poland
Bibliografia
  • [1] LI J., LIAO H., FARTASH B., HERMANSSONI L., JOHNSSONT T., Surface-dimpled commercially pure titanium implant and bone ingrowth, Biomaterials, 1997, 18, 691–696.
  • [2] MAKUCH K., KOCZOROWSKI R., Biocompatibility of Titanium and Its Alloys Used in Dentistry, Dent. Med. Probl., 2010, 47, 1, 81–88.
  • [3] BERG E., Dentists’ opinions on aspects of cast titanium restorations, J. Dent., 1997, 25, 113–117.
  • [4] SINGH R., DAHOTRE N.B., Corrosion degradation and prevention by surface modification of biometallic materials, J. Mater. Sci. Mater. Med., 2007, 18, 725–751.
  • [5] GEETHA M., SINGH A.K., ASOKAMANI R., GOGIA A.K., Ti based biomaterials, the ultimate choice for orthopaedic implants – A review, Prog. Mater. Sci., 2009, 54, 397–425.
  • [6] VENKATARMAN B.V., SUDHA S., Vanadium Toxicity, Asian J. Exp. Sci., 2005, 19, 127–134.
  • [7] ASSIS DE S.L., WOLYNEC S., COSTA I., Corrosion characterization of titanium alloys by electrochemical techniques, Electrochimica Acta, 2006, 51, 1815–1819.
  • [8] RAMAN V., TAMILSELVI S., NANJUNDAN S., RAJENDRAN N., Electrochemical Behaviour of Titanium and Titanium Alloy in Artificial Saliva, Trends Biomater. Artif. Organs, 2005, 18, 137–140.
  • [9] KHAN M.A., WILLIAMS R.L., WILLIAMS D.F., The corrosion behaviour of Ti-6Al-4V, Ti-6Al-7Nb and Ti-13Nb-13Zr in protein solutions, Biomaterials, 1999, 20, 631–637.
  • [10] KOBAYASHI E., WANG T.J., DOI H., YONEYAMA T., HAMANAKA H., Mechanical properties and corrosion resistance of Ti6Al7Nb alloy dental castings, J. Mater. Sci. Materials In Medicine, 1998, 9, 567–574.
  • [11] SITTIG C., TEXTOR M., SPENCER N. D., WIELAND M., VALLOTTON P.-H., Surface characterization of implant materials c.p. Ti, Ti-6Al-7Nb and Ti-6Al-4V with different pretreatments, J. Mater. Sci.: Materials In Medicine, 1999, 10, 35–46.
  • [12] BOVAN B.D., HUMMERT T.W., DEAN D.D., SCHWARTZ Z., Role of material surfaces in regulating bone and cartilage cell response, Biomaterials, 1996, 17, 137–146.
  • [13] CONFORTO E., ARONSSON B.-O., SALITO A., CRESTOU C., CAILLARD D., Rough surfaces of titanium and titanium alloys for implants and prostheses, Materials Science and Engineering C, 2004, 24, 611–618.
  • [14] LEINENBACH C., EIFLER D., Fatigue and cyclic deformation behaviour of surface-modified titanium alloys in simulated physiological media, Biomaterials, 2006, 27, 1200–1208.
  • [15] PASZENDA Z., WALKE W., JADACKA S., Electrochemical investigations of Ti6Al4V and Ti6Al7Nb alloys used on implants in bone surgery, Journal of Achievements in Materials and Manufacturing Engineering, 2010, 38, 24–32.
  • [16] HIROMOTO S., NODA K., HANAWA T., Development of electrolytic cell with cell-culture for metallic biomaterials, Corrosion Science, 2002, 44, 955–965.
  • [17] KARIMI S., NICKCHI T., ALFANTAZI A., Effects of bovine serum albumin on the corrosion behaviour of AISI 316L, Co–28Cr–6Mo, and Ti–6Al–4V alloys in phosphate buffered saline solutions, Corrosion Science, 2011, 53, 3262–3272.
  • [18] BATORY D., BLASZCZYK T., CLAPA M., MITURA S., Investigation of anti-corrosion properties of Ti:C gradient layers manufactured in hybrid deposition system, Journal of Materials Science, 2008, 43, 3385–3391.
  • [19] WALKOWIAK-PRZYBYŁO M., WALCZYŃSKA M., KOMOROWSKI P., KLIMEK L., WALKOWIAK B., Proliferation of human osteoblast-like cells SAOS-2 and human endothelial cells EA.HY 926 on polished and sandblasted surfaces of titanium alloys Ti6Al4V and Ti6Al7Nb, Engineering of Biomaterials, 2011, 109–111, 39–41.
  • [20] ASTM Standard G 102–89, Standard Practice for Calculation of Corrosion Rates and Related Information from Electrochemical Measurements, 2004.
  • [21] POURBAIX M., Atlas of electrochemical equilibria in aqueous solutions, 2d English ed., Houston, 1974.
  • [22] SZEWCZENKO J., MARCINIAK J., KACZMAREK M., Corrosion resistance of anodized Ti6Al4V ELI alloy after long-term exposure to Ringer’ solution, Engineering of Biomaterials, 2011, 106–108, 21–25.
  • [23] CALLE L.M., KOLODY M.R., VINJE R.D., Corrosion behavior of stainless steels in neutral and acidified sodium chloride solutions by electrochemical impedance spectroscopy, [in:] D.A. Shifler (ed.) Corrosion in Marine and Saltwater Environments II, Electrochemical Society, 2005, 143–154.
  • [24] CHEN G., WEN X., ZHANG N., Corrosion resistance and ion dissolution of titanium with different surface microroughness, Bio-Medical Materials and Engineering, 1998, 8, 61–74.
  • [25] METIKOS-HUKOVIC M., KWOKAL A., PILJAC J., The influence of niobium and vanadium on passivity of titanium-based implants in physiological solution, Biomaterials, 2003, 24, 3765–3775.
  • [26] KIEL M., MARCINIAK J., WALKE W., SZEWCZENKO J., EIS study use of physico-chemical properties of modified Ti-6Al-4V ELI, Engineering of Biomaterials, 2011, 106–108, 159–163.
  • [27] CAI Z., SHAFER T., WATANABE I., NUNN M.E., OKABE T., Electrochemical characterization of cast titanium alloys,Biomaterials, 2003, 24, 213–218.
  • [28] TAMILSELVI S., RAMAN V., RAJENDRAN N., Corrosion behavior of Ti–6Al–7Nb and Ti–6Al–4V ELI alloys in the simulated body fluid solution by electrochemical impedance spectroscopy, Electrochimica Acta, 2006, 52, 839–846.
  • [29] AL-MOBARAK N.A., AL-SWAYIH A.A., AL-RASHOUD F.A., Corrosion Behavior of Ti-6Al-7Nb Alloy in Biological Solution for Dentistry Applications, Int. J. Electrochem. Sci., 2011, 6 2031–2042.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-31d9982c-a257-4b6a-8f78-53e716a5025b
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.