Tytuł artykułu
Autorzy
Identyfikatory
Warianty tytułu
Jednostka pomiarowa fazorów w przsyle, rozdziale i mikrosieci
Języki publikacji
Abstrakty
Alternating current, natural monopoly, hierarchical power system from the beginning, throughout several decades was easy to control and mange. Renewable energy sources injection change the power system from hierarchical – to dispersed what implied necessity to use new tools for control and protection. Installing synchrophasors in nodes of dispersed power system and linking them in dispatching center we received system of power measurement units (PMU system) enabling easer control, protect and manage. Starting from USA in the end of twentieth century, PMUs are applied in many countries in transmission, distribution and microgrids networks.
Hierarchiczny system elektroenergetyczny prądu przemiennego będący naturalnym monopolem od momentu powstania przez kilka dekad był łatwy do sterowania i zarządzania. Włączenie do takiego systemu źródeł odnawialnej energii (POZE) zamieniło system hierarchiczny na rozproszony, co spowodowało konieczność zastosowania nowych narzędzi dla sterowania i zarządzania. Zainstalowanie synchrofazorów w węzłach rozproszonego systemu elektroenergetycznego i połączenie ich w centrum dyspozycyjnym utworzyło system pomiaru elektroenergetycznych synchrofazorów (system PMU) umożliwiających łatwiejsze sterowanie, zabezpieczenia i zarządzanie systemem. Począwszy od USA w końcu ubiegłego wieku, PMU są stosowane w wielu krajach w sieciach przesyłowych, rozdzielczych i mikrosieciach.
Wydawca
Czasopismo
Rocznik
Tom
Strony
83--84
Opis fizyczny
Bibliogr. 13 poz.
Twórcy
- Katedra Informatyki na Wydziale Zarzadzania Uniwersytetu Łódzkiego
Bibliografia
- [1] Bush S.: Smart Grids. Wiley, 2014, IEEE Press
- [2] Chevalier S., Hines P.D.H.: Mitigating the Risk of Voltage Collapse Using statistical Measures From PMU Data, PWRS vol. 34, No. 1, Jan.. 2019, 120-128
- [3] Clarke E.: Circuit Analysis of A-C Power Systems. Two volumes. John Wiley, Fifth Printing 1950
- [4] Cole B.M., Chandler D.: A Model of Competitive Impression Management: Edison versus Westing-house In the AC/DC Standards War. Academy of Management Proceedings, Vol. 2014, No. 1 (Pub-lished Online: 30 Nov. 2017 | https://doi.org/10.5465/ambpp.2014,10636abstract
- [5] Cui M., Wang J., Tan J., Florita F.L., Hang T.: A Novel Event Detection Method Using PMU Data with High Precision. PWRS vol. 34, No. 1, Jan. 2019, 454-467
- [6] Fajarollahi M., Shashavari A/. Stewart E.M., Mohsenian A.: Locating the Source of Event in Power Distribution Systems Using Micro-PMU Data. PWRS vol. 33, No. 6, Nov. 2018, 6343-6355
- [7] Ghahremani E., Kamwa I.: Local and Wide-Area PMU-Based Decentralized Dynamic State Estimation in Multimachine Power Systems. PWRS vpl.31, No.1, Jan.2016, 547-555
- [8] 0Mohsenian-Rad H., Stewart E., Cortez E.: Distribution Synchrophasors. IEEE PE vol. 16, , 3/2018,26-34
- [9] Paul A., Kamwa I. Ióos., Ġ.: Generalized dynamic state Estimation Using a Federation of Extended Kalman Filters With Intermittent PMU Data from Generator terminals. PWRS vol.33, No. ^ Nov. 20186109-6119
- [10] Phadke A.G.: Phasor measurement units, WAMS, and their applications in protection and control of power systems. Journal of Modern Power Systems and Clean Energy. July 2018, Volume 6, Issue 4, pp 619–629
- [11] Werbo T,, Vittal V., Kolluri S., Wong S.M.: A Potential Island Formation Scheme Supported by PMU Measurements. PWRS vol.31 o.1, Jan. 2016, 423-429
- [12] Wu Y.,Musavi M.,, Lerley P.: Synchrophasor-Based Monitoruing of Critical Generator Buses for Transient Stabioity. PWRS, vol.31 No.1,Jan. 2016, 287-298
- [13] Zieliński J.S.: Nowe tendencje w elektroenergetyce krajów rozwiniętych. Biuletyn techniczno-informacyjny SEP, Oddział Łódzki, 1/2019, ISSN 2082-7377, 16-17
Uwagi
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2019).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-31b8073e-0660-45c5-a486-289977ef609c