PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Evaluation of patch tests results–research and development of technique based on infrared thermography

Autorzy
Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Ocena wyników testów płatkowych–badanie i rozwijanie metody opartej na termografii
Języki publikacji
EN
Abstrakty
EN
Skin tests in allergology are a method of medical diagnosis that attempts to provoke a small, controlled allergic response. Evaluation of the patch test depends on visual assessment so it is not an objective method, because it does concern only skin surface and difficulties like changes in skin pigmentation, atopic skin, black race skin or delayed reaction may occur. Studies with use of thermography confirm that skin surface allergic reaction is strictly connected with temperature increasing at that area so such technique may be the key for impartial evaluation. Carried out tests, also confirmed information from literature review, that to obtain valuable infrared images large intervals between allergens must be kept.
PL
Testy skórne w alergologii to metoda diagnostyczna polegająca na wywołaniu małej, kontrolowanej reakcji alergicznej. Ocena testów płatkowych oparta jest na ocenie wizualnej, której podlega tylko powierzchni skóry, a więc nie jest obiektywna, gdyż mogą mieć na nią wpływ takie czynniki jak zmiany w pigmentacji skóry, skóra atopowa, skóra rasy czarnej lub opóźniona reakcja. Badania z użyciem termografii potwierdziły, że reakcja alergiczna powierzchni skóry jest ściśle powiązana ze wzrostem temperatury w tym obszarze, więc technika ta może być kluczowa w dążeniu do obiektywnej oceny. Przeprowadzone badania potwierdziły także informację z przeglądu literatury, że aby otrzymać wartościowe termogramy należy zachować duże odstępy pomiędzy aplikowanymi alergenami.
Czasopismo
Rocznik
Strony
3--8
Opis fizyczny
Bibliogr. 16 poz., rys., tab.
Twórcy
autor
  • MONIT SHM Sp. z o.o., ul. Lublańska 34, 31-476 Kraków, Poland, tel. +48 12 6277709
autor
  • AGH University of Science and Technology, Department of Robotics and Mechatronics, al. A. Mickiewicza 30, 30-059 Kraków, Poland, tel. +48 12 6173640, fax. +48 12 6343505
Bibliografia
  • [1] Lahiri B.B., Bagavathiappan S., Jayakumar, Philip J., Medical applications of infrared thermography: A review, Infrared Physics & Technology, vol. 55, pp. 221-235, 2012
  • [2] Laino L., di Carlo A., Telethermography: an objective method for evaluating patch test reactions, Dermatology, vol. 20, No. 2, pp. 175-180, 2010
  • [3] Szentkuti A., Kavanagh H.S., Grazio S., Infrared thermography and image analysis for biomedical use, Periodicum biologorum, vol. 113, no 4, pp. 385-392, 2011
  • [4] Diakides N.A., Bronzino J.D., ed., Medical Infrared Imaging, CRC Taylor&Francis, 2008
  • [5] Beltrani V.S., Bernstein I.L., Cohen D.E., Fonacier L., Contact dermatitis: a practice parameter, Annals of allergy, asthma & immunology, vol. 97, 2006
  • [6] Ring E.F.J., Ammer K., Infrared thermal imaging in medicine, Physiological Measurement, vol. 33, pp. R33-R46, 2012
  • [7] Ring E.F.J., Mcevoy H., Jung A., Zuber J., Machin G, New standards for devices used for the measurement of human body temperature, Journal of Medical Engineering & Technology, vol. 34, no. 4, pp. 249–253, 2010
  • [8] http://www.icdrg.org (visited 23.03.2015)
  • [9] ISO/TR 13154:2009 Medical electrical equipment-deployment, implementation and operational guidelines for identifying febrile humans using a screening thermograph
  • [10] IEC 80601-2-59:2008, Ed. 1.0 Medical electrical equipment-part 2-59: particular requirements for the basic safety and essential performance of screening thermography for human febrile temperature screening
  • [11] http://www.flir.com (visited 23.02.2015)
  • [12] http://www.chemotechnique.se (visited 23.03.2015)
  • [13] http://www.smartpractice.com/shop/wa/category?cn=Products-Finn-Chambers-On-Scanpor&id=508224&m=SPA (visited 23.03.2015)
  • [14] Vollmer M., Möllmann K.-P., Infrared thermal imaging. Fundamentals, research and applications, WILEY-VCH Verlag GmbH & Co. KGaA, 2010
  • [15] Gavriloaia G., Gavriloaia M.-R., Improving quality of medical infrared images by using bioheat equation, Proccedings of the 3rd International Conference on E-Health and Bioengineering – EHB 2011
  • [16] www.monithshm.pl
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-30a16823-1f57-4c70-a6e0-0b486704ef9f
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.