Full Contoured Tooth-Implant Supported 3-Pointic All-Ceramic Denture During Occlusal Load Transfer in Lateral Region

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Implant and a tooth supported dentures are avoided by dentists because of uneven distribution of occlusal loads between a stiffer implant and a more pliable tooth. The hypothesis was that a 3-point all-ceramic bridge supported on a natural second premolar tooth and a two-pieces typical implant bears safely mastication loads. The finite element analysis showed that the implant splinted by all-ceramic zirconium bridge with the second premolar was safe under lateral mastication load, but there was found an overload at wide zone of bone tissue around the implant under the load of 800 N. The patients can safely masticate, but comminution of hard food should be avoided and they should be instructed that after such an indiscretion they need to contact a dental professional, because, in spite of integrity of the prosthesis, the bone tissue around the implant may fail and there is a hazard of intrusion of the tooth.
Twórcy
autor
  • Silesian University of Technology, Institute of Engineering Materials and Biomaterials, Faculty of Mechanical Engineering, 18 A Konarskiego Str., Gliwice 44-100, Poland
autor
  • Silesian University of Technology, Institute of Engineering Materials and Biomaterials, Faculty of Mechanical Engineering, 18 A Konarskiego Str., Gliwice 44-100, Poland
autor
  • Silesian University of Technology, Institute of Engineering Materials and Biomaterials, Faculty of Mechanical Engineering, 18 A Konarskiego Str., Gliwice 44-100, Poland
Bibliografia
  • [1] K. X. Michalakis, P. Calvani, H. Hirayama, J Dent Biomech. 3, (2012): DOI : 10.1177/1758736012462025
  • [2] I. E. Naert, J.A.J. Duyck, M.M.F. Hosny, et al., Clin Oral Implants Res. 12, 237-244 (2001).
  • [3] T. Lindh, S. Dahlgren, K. Gunnarsson, et al., Int J Prosthodont. 14, 321-328 (2001).
  • [4] R. Skalak, J Oral Implantol. 12, 350-356 (1986).
  • [5] L. A. Weinberg, B. Kruger, Oral Surg Oral Med Oral Pathol. 78, 22-27 (1994).
  • [6] D. Lundgren, L. Laurell, Periodontol 2000. 4, 23-40 (1994).
  • [7] T. Burak Ozcelik, E. Ersoy, B. Yilmaz, J Prosthodont. 20,1, 16-28 (2011). DOI : 10.1111/j.1532-849X.2010.00654.x.
  • [8] G. Menicucci, A. Mossolov, M. Mozzati, et al., Clin Oral Implants Res. 13, 334-344 (2002).
  • [9] C. L. Lin, S.H. Chang, J.C. Wang, et al., J Dent. 34, 682-691 (2006).
  • [10] C. L. Lin, , J.C. Wang, S.H. Chan, Clin Oral Implants Res. 19, 107-117 (2008).
  • [11] T. Ozcelik, A.E. Ersoy. J Prosthodont. 16, 107-116 (2007).
  • [12] R. Kayacan, R. Ballarini, R.L. Mullen, J Prosthet Dent. 78, 391-399 (1997).
  • [13] C. L. Lin, S.H. Chang, J.C. Wang, Chang Gung Med J. 29, 143-153 (2006).
  • [14] J. Żmudzki, G. Chladek, J. Kasperski, J Mech Med Biol. 12, 1250087(2012).
  • [15] J. Żmudzki, G. Chladek, J. Kasperski, Biomech Model Mechanobiol. 14, 679-691 (2015). DOI : 10.1007/s10237-014-0642-0
  • [16] Ł. Reimann, J. Żmudzki, L.A. Dobrzański, Acta Bioeng Biomech. 17, 1, 51-59 (2015).
  • [17] R. Kenney, M.W. Richards, J Prosthet Dent. 80, 5, 55-64 (1998).
  • [18] U. Lekholm, G.A. Zarb, Patient selection and preparation. In: Branemark PI, Zarb GA, Albrektsson T (eds). Tissueintegrated Prostheses: Osseointegration in Clinical Dentistry. Quintessence, Chicago 1985.
  • [19] C. L. Lin, J.C. Wang, Y.C. Kuo, J Biomech. 39, 453-463 (2006).
  • [20] B. R. Merz, S. Hunenbart, U.C. Belser, Int J Oral Maxillofacial Implants. 15, 519-526 (2000).
  • [21] A. M. O’Mahony, J. L. Williams, P. Spencer, Clin Oral Implants Res. 12,6, 648-657 (2001).
  • [22] S. M. Alencar, L. B. Nogueira, W. Lealde Moura, et al., J Prosthodont. 20, (2015). DOI : 10.1111/jopr.12384.
  • [23] H. M. Frost, Angle Orthod. 64, 175-188 (1994).
  • [24] J. Żmudzki, W. Walke, W. Chladek, Influence of model discretization density in FEM numerical analysis on the determined stress level in bone surrounding dental implants, in: E. Piętka, J. Kawa Information technologies in biomedicine. Berlin Springer (2008), Advances in Soft Computing 47, 559.
  • [25] H. Van Oosterwyck, J. Van der Sloten, R. Puers, I. Naert, Mecanica 37, 441-451 (2002).
  • [26] I. E. Naert, M. Hooghe, M. Quirynen, D. van Steenberghe, Clin Oral Invest. 1, 119-124 (1997).
  • [27] D. Jörn, P. Kohorst, S. Besdo, et al., J Prosthet Dent. 12, 2, 340-348 (2014). DOI : 10.1016/j.prosdent.2013.10.016. Epub 2014 Feb 14.