Knitted Multi-Functional Clothing - the Main Part of a Textile Incubator for Premature Babies

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Dziany ubiór wielofunkcjyjny jako część inkubatora tekstylnego dla dzieci przedwcześnie urodzonych
Języki publikacji
EN
Abstrakty
EN
This publication presents an innovative concept for the construction of a textile incubator. A literature study was conducted concerning care for premature babies at neonatology intensive care units. Based on the physiological requirements of preterm infants, a textile incubator model was designed and manufactured. The incubator presented is composed of several layers of material. The primary function of the incubator is to maintain thermal, sensory and humidity comfort, to cool the newborn in case of programmed therapeutic hypothermia, as well as to maintain hospital sterilisation. In the first stage of work on the textile incubator we were focused on problems of the production and maintenance of heat inside the product and cooling the newborn. The most important element of the incubator construction is the heating- cooling – moistening mat, the aim of which is to deliver or receive heat from the premature baby, and to maintain adequate environmental moisture. Because the construction of the humidification mechanism is quite complicated, it is not presented in this publication. The assumed extreme values of temperatures of the functional mat are in the following ranges: for additional heating - such as stationary incubators Tmax = 39 °C, with a precision of 1 °C; in the case of cooling in the medical hypothermia planned Tmin = 29 °C, with a precision of 1 °C. The mat was made in the form of a 3D structure of three-layer weft knitted fabric with channels, manufactured on a cylindrical rib-knitting machine, needle gauge E20. Technological and structural parameters of the three-layer knitted mat manufactured were defined. A test stand for the analysis of heat transfer of the heating mat was designed and constructed.
PL
Przedstawiono innowacyjną koncepcje budowy tekstylnego inkubatora. Przeprowadzono studium literaturowe w aspekcie sposobów opieki nad wcześniakami na oddziałach intensywnej terapii neonatologii. W oparciu o wymagania fizjologiczne wcześniaków został zaprojektowany i wykonany model tekstylnego inkubator. Przedstawiony inkubator składa się z kilku warstw materiałowych. Podstawową funkcją tekstylnego inkubatora jest utrzymanie komfortu termicznego, sensorycznego, wilgotności, schładzanie noworodka w przypadku programowanej hipotermii leczniczej oraz zachowania sterylizacji szpitalnej. Najważniejszym elementem budowy inkubatora tekstylnego jest mata grzewczo – chłodząco - nawilżająca, która ma za zadanie dostarczać lub odebrać ciepło od wcześniaka oraz utrzymać odpowiednie środowisko wilgoci. W tym celu zaprojektowano i wykonano trójwarstwową rządkową dzianinę kanałową 3D, na szydełkarce cylindrycznej dwułożyskowej o numerze uiglenia E 20. Zdefiniowano parametry technologiczne i strukturalne wykonanej dzianej maty trójwarstwowej. Zaprojektowano i wykonano stanowisko badawcze do analizy transportu ciepła maty grzewczej.
Rocznik
Strony
140--147
Opis fizyczny
Bibliogr. 19 poz., rys., tab.
Twórcy
autor
  • Department of Knitting Technology, Faculty of Material Technologies and Textile Design, Lodz University of Technology, Łódź, Poland
  • Department of Knitting Technology, Faculty of Material Technologies and Textile Design, Lodz University of Technology, Łódź, Poland
Bibliografia
  • 1. Blencowe H, Cousens S, Chou D, Oestergaard M Z, Say L, Moller A, Kinney M and LawnBorn J. 15 million preterm births: priorities for action based on national, regional and global estimates. Born Too Soon: „The Global Arction Report on Preterm Brith”. World Health Organization 2012. ISBN 978 92 4 150343.
  • 2. Troszyński M. Perinatal mortality of fetuses and newborns in 1999-2008 in Poland. (in polish). Medycyna Wieku Rozwojowego, 2010, XIV,2; s.129-137.
  • 3. Kochman D. Infant – immature human being. (in polish) Magazyn Pielęgniarki i Położne. Nr 7– 8 Lipiec – Sierpień 2010r. INDEX 340960. ISSN 1425- 6789.
  • 4. Mazurak M, Czyżewska M and Paluszyńska D. Neonatology Atlas. Wydawnictwo PZWL 2012. ISBN: 9788320044898.
  • 5. Krause M. Thermoregulation of the human body and thermal load. (in polish) Nauka o pracy - bezpieczeństwo, higiena, ergonomia. Pakiet edukacyjny dla uczelni wyższych.
  • 6. Gray P H and Flenady V. Cot-nursing versus incubator care for preterm infants. Published by John Wiley & Sons, Ltd 2011. DOI: 10.1002/14651858. CD003062. pub2.
  • 7. Antoszewski Z, Gwóźdź B and Skalski J. Hypothermia and hyperthermia in clinical use. (in polish) Wydawnictwo „Śląsk” Katowice 2000. ISBN 83-7164-231-8.
  • 8. Świetliński J and Musialik – Świetlińska E. Skin protection in low weight newborns. Postępy neonatologii. Wydawnictwo Polonorum Societas Neonatologica. nr. 2*2001. ISSN 1640 – 3959.
  • 9. Manual: Neonatal Incubator of Model C 2000 Dräger.
  • 10. Szczapa J. Basics of Neonatology. (in polish) Wydawnictwo Lekarskie PZWL 2007., ISBN 97-8832 – 0041 – 613.
  • 11. Meyer M P, Payton M P, Salmon A, Hutchinson C and Klerk A. A clinical comparison of radiant warmer and Incubator care for preterm infants from birth to 1800gms. Pediatrics 2001; 2 (108): 395-401.
  • 12. Iaione F, Moraes R. Microprocessed Assessment of Newborn Incubator Functionality. Proceedings of the 22th Annual EMBS International Conference, Chicago IL, United States, July 23-28, 2000.
  • 13. Webster J G.. Medical instrumentation application and design. 4th Edition, February 2009.
  • 14. Amer G M and Al. – Aubidy K M. Novel technique to control the premature infant incubator system using ann. Third International Conference on Systems, Signals & Devices, March 21-24, 2005 – Sousse, Tunisia. Volume I Systems Analysis & Automatic Control.
  • 15. Baker J P. Historical Perspective :The Incubator and the Medical Discovery of the Premature Infant. Journal of Perinatology 2000; 5: 321–328.
  • 16. Rozalska-Walaszek I, Lesiuk W, Aftyka A and Lesiuk L. Nursing care of a premature baby treated in intensive care newborn. (in polish) Problemy Pielęgniarstwa 2012; 20 (3): 409–415.
  • 17. O’Donohue E. Spreading Warmth. Embrace 2013 Annual Report.
  • 18. http://embraceglobal.org/embrace-warmer/
  • 19. Krucińska I, Konecki W and Michalak M. Measuring systems in the textile industry. (in polish) Wydawnictwo Politechniki Łódzkiej 2006., ISBN 83–7283–148–3.
Uwagi