PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Smart grid condition assessment: concepts, benefits and developments

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Power delivery infrastructures are overstrained and suffer from overaged conditions, not only in the developed, but also in the more industrialized countries. The aim of the smart grid is to provide a more reliable and efficient electric power grid. Condition assessment is an essential and effective part of the reliability for electric grid components; also, it reflects the physical state of the electricity asset in a generation, transmission, distribution, and consumers sides. In this paper, condition assessment of electric grid assets will be discussed and illustrated within the context of smart grid principle. In addition, the proposed condition assessment architecture and the objective of condition assessment for smart grid equipment will be explored and analyzed. Moreover, the potential benefits of such smart system as compared to the traditional power system will be presented. This paper aims to add significant contribution to a smart grid theory.
Wydawca
Rocznik
Strony
147--163
Opis fizyczny
Bibliogr. 45 poz., rys.
Twórcy
autor
  • Texas A&M University at Qatar, Doha, Qatar
autor
  • Texas A&M University at Qatar, Doha, Qatar
Bibliografia
  • [1] FANG X., MISRA S., XUE G., YANG D., Smart grid – the new and improved power grid: A survey, IEEE Commun. Surveys Tutorials, 2012.
  • [2] BAYINDIR R., HOSSAIN E., VADI S., The path of the smart grid -the new and improved power grid, International Smart Grid Workshop and Certificate Program (ISGWCP), 2016, 1–8.
  • [3] FARHANGI H., The path of the smart grid, IEEE Transactions on Power and Energy, 2010, 8, 1, 18–28.
  • [4] ZHOU X., Development prospects of power grid and power system technology in changes with renewable energy, Huadian Technology, 2011, 33, 12, 1–3.
  • [5] ZHOU, JINJU, LINA HE, CANBING LI, YIJIA CAO, XUBIN LIU, YINGHUI GENG, What’s the difference between traditional power grid and smart grid? – From dispatching perspective, IEEE PES Asia-Pacific in Power and Energy Engineering Conference (APPEEC), 2013, 1–6.
  • [6] WEI M., WANG W., Greenbench: A benchmark for observing power grid vulnerability under datacentric threats, INFOCOM, 2014.
  • [7] DUBROVA E., Fault-Tolerant Design, Springer, 2013, 5–20.
  • [8] OKUBO H., Enhancement of electrical insulation performance in power equipment based on dielectric material techniques, IEEE Conference on Electrical Insulation and Dielectric Phenomena, Cancun, Mexico, 2011, 1–19.
  • [9] HAN J., MERTE R., HERMAN H., Condition assessment of epoxy-impregnated insulating materials, Conference Record of the 2010 IEEE International Symposium on Electrical Insulation (ISEI), 2010, 1–4
  • [10] BAIRD P.J., HERMAN H., STEVENS G.C., Rapid Non-Destructive Condition Assessment of Insulating Materials, IEEE International Symposium on Electrical Insulation, ISEI 2008., 2008, 742–745.
  • [11] NARANPANAWE W.M.L.B., RATHNAYAKE R.M.H.M., FERNANDO M.A.R.M., JAYANTHA G.A., Condition assessment of generator stator insulation by DC ramp and IR tests, IEEE International Conference on the Industrial and Information Systems (ICIIS), 2013.
  • [12] FARAHANI M., BORSI H., GOCKENBACH E., Dielectric Response Studies on Insulating System of High Voltage Rotating Machines, IEEE Transactions on Dielectrics and Electrical Insulation, 2006, 13, 1, 383–393.
  • [13] PENG S., JIAN L., YUANHONG W., YONGLONG Y., TIANYAN J., Condition assessment of wind turbine generators based on cloud model, IEEE International Conference on Solid Dielectrics (ICSD), 2013, 146–151.
  • [14] WANG, SONG, XIANG-LONG LI, JUN-HAO LI, XIAO-HUI ZHAO, YAN-MING L.I., Experimental Study for Outside Propagation Characteristic of the UHF Signal Emitted by Partial Discharge in Transformers, Electrical Insulation Conference (EIC), 2014, 286–289.
  • [15] MIRZAIE M., GHOLAMI A., TAYEBI H.R., Insulation Condition Assessment of Power Transformers Using Accelerated Ageing Tests, Turkish Journal of Electrical Engineering and Computer Sciences, 2009, 17, 1, 39–54.
  • [16] WANG M., VANDERMAAR A.J., Review of condition assessment of power transformers in service, IEEE Electr. Insul. Mag., 2002, 18, 5, 8–17.
  • [17] HALIM H.S.A., GHOSH P., Condition assessment of medium voltage underground PILC cables using partial discharge mapping and polarization index test results, IEEE International Symposium on Electrical Insulation Conference, 2008, 32–35.
  • [18] ANANDAKUMARAN K., SEIDL N., CASTALDO P.V., Condition assessment of cable insulation systems in operating nuclear power plants, IEEE Transactions on Dielectrics and Electrical Insulation, 1999, 6, 3, 376–384.
  • [19] LAULETTA J.L., SOZER Y., DE ABREU-GARCIA J.A., A novel sensing device for underground cable condition assessment, IEEE Electrical Insulation Conference (EIC), 2015, 523–528.
  • [20] STEPHEN B., STRACHAN S.M., MCARTHUR S.D.J., MCDONALD J.R., HAMILTON K., Design of trip current monitoring system for circuit breaker condition assessment, IET Generation, Transmission & Distribution 1, 2007, 1, 89–95.
  • [21] BEATTIE S., Circuit breaker condition assessment by vibration and trip coil analysis, IEEE Colloq. Monitors and Condition Assessment Equipment Digest, 1996, 186.
  • [22] DONGMEI Z., WEICHEN L., XU Z., Relay protection condition assessment based on variable weight fuzzy synthetic evaluation, IEEE Conference on Technologies for Sustainability (SusTech), 2014, 115–120.
  • [23] STONE G.C., LLOYD B.A., CAMPBELL S.R., On-line monitoring for condition assessment of motor and generator stator windings, IEEE on Pulp and Paper Industry Technical Conference, 1994, 94–103.
  • [24] LLOYD B.A., STONE G.C., STEIN J., Motor insulation condition assessment using expert systems software, IEEE Pulp and Paper Industry Technical Conference, 1994, 60–67.
  • [25] KUUSIK A., NOMM S., OVSJANSKI S., ORUNURM L., REILENT E., Wearable system for patient motor condition assessment and training monitoring, IEEE on Point-of-Care Healthcare Technologies (PHT), 2013, 192–195.
  • [26] SU Q., Insulation condition monitoring of electrical plant – How to interpret the collected data and diagnose incipient faults, Keynote speech in International Conference on Machines, 2009, 12–20.
  • [27] SU Q., MI C., LAI L.L., AUSTIN P., A fuzzy dissolved gas analysis method for the diagnosis of multiple incipient faults in a transformer, IEEE Trans. Power Sys., 2000, 15, 2, 593–598.
  • [28] SU C.Q., Case studies: Lessons learnt from the failure of a new 230kV transformer-cable termination, IEEE Electr. Insul. Mag., 2010, 26, 1, 15–19.
  • [29] SU Q., Failure analysis of three 230 kV XLPE cables, in Proceedings of IEEE Transmission and Distribution Conference, 2010, 22–25.
  • [30] SOBHANI-TEHRANI, EHSAN, KHASHAYAR KHORASANI, Fault diagnosis of nonlinear systems using a hybrid approach, Springer Science & Business Media, 2009, 383.
  • [31] GAGE M., Equipment Maintenance and Replacement Decision Making Processes, PhD diss., California Polytechnic State University, San Luis Obispo, 2013.
  • [32] ARIVAMUDHAN M., SANTHI S., ABIRAMI S., SUGASINI G., Improved Detection Sensitivity with Combined WPT and HHT for Power Transformer Winding Deformation Analysis, International Journal of Computer Applications, 2014.
  • [33] BEATTIE S., Circuit breaker condition assessment by vibration and trip coil analysis, Monitors and Condition Assessment Equipment (Digest No. 1996/186), IEE Colloquium on, 9–1. IET, 1996.
  • [34] WANG M., VANDERMAAR A.J., SRIVASTAVA K.D., Review of condition assessment of power transformers in service, IEEE Elect. Insul. Mag., 2002, 18, 6, 12–25.
  • [35] ZHIMIN HE, YADONG LIU, JING CHEN, WANJIAN BAI, GEHAO SHENG, XIUCHEN JIANG, A Multiparameter Comprehensive Analytical Method for Online Assessing Power Transformer Condition, Przegląd Elektrotechniczny, 2013, 89, 1a, 219–222.
  • [36] IEC, IEC 61198 1993-09, Mineral Insulating Oils Methods for the Determination of 2-furfural and Related Compounds, 1993.
  • [37] ROBALINO D., Accurate temperature correction of dissipation factor data for oil-impregnated paper insulation bushings: Field experience, Electrical Insulation and Dielectric Phenomena (CEIDP), Annual Report Conference on, 2011, 251–254.
  • [38] BALZER G., Condition assessment and reliability centered maintenance of high voltage equipment, Proceedings of 2005 International Symposium on Electrical Insulating Materials, (ISEIM 2005), 2005, 1, 259–264.
  • [39] FENG Q., YONG LIANG LIANG, Condition assessment of substation equipment based on intelligence information fusion, IEEE PES Innovative Smart Grid Technologies, 2012, 1–5.
  • [40] MEHDI BIGDELI, JAFAR AGHAJANLOO, Condition assessment of transformer insulation using dielectric frequency response analysis by artificial bee colony algorithm, Archives of Electrical Engineering, 2016, 65, 1, 45–57.
  • [41] HONG, KAIXING, HAI HUANG, JIANPING ZHOU, Winding condition assessment of power transforme based on vibration correlation, IEEE Transactions on Power Delivery, 2015, 30, 4, 1735–1742.
  • [42] REFAAT SHADY S., ABU-RUB HAITHAM, SAAD M.S., ABOUL-ZAHAB E.M., ATIF IQBAL, Detection, Diagnoses and Discrimination of Stator Turn to Turn Fault and Unbalanced Supply, IEEE International Conference on Power and Energy (PECON 2012), 2012, 2–5.
  • [43] REFAAT SHADY S., HAITHAM ABU-RUB, SAAD M.S., ABOUL-ZAHAB E.M., ATIF IQBAL, Discrimination of Stator Winding Turn Fault and Unbalanced Supply Voltage in Permanent Magnet Synchronous Motor Using ANN, IEEE – Powereng 2013, International Conference on Power Engineering, Energy and Electrical Drives, Turkey, 2013, 858–863.
  • [44] GARCIA B., BURGOS J.C., ALONSO Á.M., Transformer tank vibration modeling as a method of detecting winding deformations – Part I: Theoretical foundation, IEEE Trans. Power Del., 2006, 21, 1, 157–163.
  • [45] SPARLING B.D., AUBIN J., Power Transformer Life Extension Through Better Monitoring, General Electric, 2007.
Uwagi
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę (zadania 2017).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-2b6c7e8c-b892-4198-ba69-3064a2413dd0
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.