Application of optical current sensors In electric substations

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Zastosowanie optycznych czujników prądu w podstacjach elektrycznych
Języki publikacji
EN
Abstrakty
EN
Despite the fact that current transformers have been used for many years in certain sections of the electrical network, in power supply, to power the circuits of an electrical measuring installation, meters, and relay automation installations, they have various disadvantages, in particular, due to a fairly high accuracy class and error when integrated with modern digital technology. Depending on the requirements for traditional current transformers, they are divided into accuracy classes, i.e. 0.2; 0.5; 1; 3; 10. It is these accuracy classes that determine the scope of current transformers (laboratory, general technical devices, relay protection, etc.).
PL
Pomimo faktu, że przekładniki prądowe są od wielu lat stosowane w niektórych odcinkach sieci elektrycznej, w zasilaniu, do zasilania obwodów elektrycznej instalacji pomiarowej, liczników, instalacji automatyki przekaźnikowej, mają one różne wady, w szczególności ze względu na dość wysoka klasa dokładności i błąd po zintegrowaniu z nowoczesną technologią cyfrową. W zależności od wymagań stawianych tradycyjnym przekładnikom prądowym, dzieli się je na klasy dokładności, tj. 0,2; 0,5; 1; 3; 10. To właśnie te klasy dokładności określają zakres przekładników prądowych.
Rocznik
Strony
132--134
Opis fizyczny
Bibliogr. 22 poz., rys.
Twórcy
  • Azerbaijan State Oil and Industry University
  • Azerbaijan State Oil and Industry University
  • Azerbaijan State Oil and Industry University
autor
  • Azerbaijan State Oil and Industry University
Bibliografia
  • [1] Cease T.W. and Johnston P., “A magneto-optic current transducer”, IEEE Trans. on PowerDelivery, vol. 5, 548-555, 1990.
  • [2] Bohnert K., Gabus G., Nehring J., and Brändle H., “Temperature and vibration insensitive fiber-optic current sensor”, J. of Lightw.Technol., vol. 20, 267-276, 2002.
  • [3] Nicatti P.A. and Robert P., “Stabilized current sensor using a Sagnac interferometer”, J. Phys.E: Sci. Instrum., vol. 21, 791- 796, 1988.
  • [4] Torbus S.A., Dutkiewicz P., Projektowanie jednomodowych światłowodów telekomunikacyjnych dla czujników wykorzystujących magnetooptyczne zjawisko Faradaya. Przegląd Elektrotechniczn, Volume 91, No2, pp.118-122, 2015.
  • [5] Rzayeva S.V., Mammadov N.S. and Ganiyeva N.A. “Overvoltages During Single-Phase Earth Fault in Neutral-Isolated Networks (10÷35) kV”. Journal of Energy Research and Reviews 13 (1), pp. 7-13, 2023
  • [6] Rzayeva S.V., Mammadov N.S., Ganiyeva N.A. “Neutral grounding mode in the 6-35 kv network through an arcing reactor and organization of relay protection against single-phase ground faults”. Deutsche internationale Zeitschrift für zeitgenössische Wissenschaft / German International Journal of Modern Science №42(22) pp.31-34
  • [7] Enokihara A., Izutsu M., and Sueta T., “Optical fiber sensors using the method of polarizationrotatedreflection”, J. Lightw.Technol., vol. 5, 1584-1590, 1987.
  • [8] Short S.X., Tselikov A.A., J.U. de Arruda, and Blake J.N., “Imperfect quarter-waveplatecompensation in Sagnac interferometer-typecurrent sensors”, J. Lightw.Technol., vol. 16,1212-1219, 1998.
  • [9] Blake J., Tantaswadi P., and R.T. de Carvalho,“In-line Sagnac interferometer current sensor”,IEEE Trans. Power Delivery, vol. 11, 116-121,1996.
  • [10] Tang D., Rose A. H., Day G. W., and Etzel S. M., “Annealing of linear birefringence insingle-mode fiber coils: applications to opticalfiber current sensors”, J. Lightw. Technol., vol., 1031-1037, 1991.
  • [11] Short S.X., Tselikov A.A., J.U. de Arruda, and Blake J.N., “Imperfect quarter waveplatecompensation in Sagnac interferometer-type current sensors”, J. Lightw. Technol., vol. 16,1212-1219, 1998.
  • [12] Bohnert K. and Nehring J., “Fiber-optic sensing of voltages by line integration of the electricfield”, Opt. Lett., vol. 14, 290-292, 1989.
  • [13] Gavrichev V. D., Dmitriev A. L., Fiber-optic sensors magnetic field / Study Guide. - St. Petersburg: SPbNIU ITMO, 2013.p. 83
  • [14] Udd E. Fiber optic sensors. M.: Technosfera, 2008. - 520s.
  • [15] Jackson R.G. Latest sensors. M: Technosphere, 2007.- 384p.
  • [16] Horowitz S. H. and Phadke A. G., “Current and voltage transformers”, in Power System Relaying, 4th ed. John Wiley and Sons, 2014, ch. 3, pp. 46–73.
  • [17] Instrument transformers - Part 2: Additional requirements for current transformers, IEC 61869-2:2012, 2012.
  • [18] Jackson, D.A. An optical system with potential for remote health monitoring of subsea machinery.Meas. Sci. Technol. 2009, 20, 1– 8.
  • [19] Perciante, C.D.; Ferrari, J.A. Magnetic crosst alk minimization in optical current sensors. IEEETrans. Instrum. Meas. 2008, 57, 2304–2308
  • [20] Drexler, P.; Fiala, P. Utilization of Faraday mirror in fiber optic current sensors. Radioengineering2008, 17, 101–107.
  • [21] S.A.Torbus. Current–polarization-dependent loss” optical fibre sensor. Przegląd Elektrotechniczn, Volume 95, pp.171-174, 2015
  • [22] Zhang P., Halliday D., Faraday Effect Optical Current Sensor, IEEE 0-7803-3143-5 (1996)