PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Pulsed electro-magnetic joint lubrication therapy aided with the run-walk

Autorzy
Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Pulsująca elektromagnetyczna terapia smarowania stawów łączona biego-chodem
Języki publikacji
EN
Abstrakty
EN
The topic of the presented paper concerns a new idea of therapy of human joint diseases, using pulsed electromagnetic lubrication treatment implemented by the run and walk training. Here, the thesis is proved that the pulse-electro-magnetic lubrication connected with the run-walk training increases energy burn, metabolism and it finally leads to the betterment of the performed therapy. The research performed in this paper is realized using the following devices: 1st apparatus generates Pulsed Electro-Magnetic Field (PEMF),2nd device produces Magnet-Tronic Field (MF-8), 3rd apparatus creates Multi Tronic activities (MT-3), 4th device delivers and resolves the Segmental Body Composition Analysis (SBCA), 5th is the electronic pedometer. Moreover in presented research are applied the author's experience gained in German research institutes and practical results of measurements and information from students, patients. The betterments of results obtained during the pulsed electro- magneto-therapy of the typical human cartilage diseases applying proper field shapes, frequencies, inductions and time durations, indicate the necessity of simultaneous training efforts in the form of run and walk to satisfy the best effects after performed treatments.
PL
Tematem niniejszej pracy jest nowa idea terapii chorób stawowych człowieka polegająca na smarowaniu pulsującym polem elektromagnetycznym w połączeniu z treningiem biegu i chodu. Wykazuje się tezę o udoskonaleniu terapii zwiększającej przemianę materii wraz z energią spalania cellulitu poprzez pulsujące elektromagnetyczne smarowanie połączone z treningiem biegu i chodu. W badaniach eksperymentalnych wykorzystuje się następujące przyrządy i materiały: PEMF Magcell-Arthro przyrząd elektroniczny do zabiegów chrząstki stawowej, Analizator Tanita MC 780U do pomiaru składu ciała, krokomierz Garmin ltd 2015, doświadczenie autora zdobyte w niemieckich instytutach badawczych, a także wywiady lekarskie od pacjentów i studentów. Doskonalenie rezultatów uzyskanych podczas pulsującej elektromagnetycznej terapii typowych schorzeń chrząstki stawowej człowieka dla właściwych kształtów, częstotliwości i indukcji pola oraz czasu zabiegu wskazuje na konieczność jednoczesnego wysiłku treningowego w formie biegania lub chodu umożliwiającego uzyskanie optymalnych rezultatów zabiegu.
Czasopismo
Rocznik
Tom
Strony
109--115
Opis fizyczny
Bibliogr. 27 poz., rys., tab., wz.
Twórcy
  • Technical University of Koszalin, Institute of Technology and Education, Śniadeckich Street 2, 75-453 Koszalin, Poland
Bibliografia
  • 1. Bagnato G. L., Miceli G., Marino N., Sciortino D., Bagnato G. F.: Pulsed electromagnetic fields in knee osteoarthritis: a double blind, placebo-controlled, randomized clinical trial.PMIDs 24106421, Rheumatology 2016; 55; 755–762.
  • 2. Cieślar G., Sieroń A., Adamek M., Żmudzinski J.: Wykorzystanie zmiennego pola magnetycznego w leczeniu choroby zwyrodnieniowej stawów. Balneol. Pol. 1992, T. 34, nr 1–4, 133–148.
  • 3. Czaban A., Frycz M., Horak W.: Effect of the Magnetic Particles Concentration on the Ferro-Oil’s Dynamic Viscosity in Presence of an External Magnetic Field in the Aspect of Temperature Changes, Journal of KONES Powertrain and Transport, 2013, Vol. 20, No. 2, 55–60.
  • 4. Ianniti T., Fistetto G., Esposito A., Rottigi V., Palmieri B.: Pulsed electromagnetic field therapy for management of osteoarthritis-related pain,stiffness and physical function: clinical experience in the eldery. PMIDs:26705327, Clinical Interventions in Aging, 2013, 8; 1289–1293.
  • 5. Siauve N., Scorretti R., Burais N., Nicolas L.: Electrorheological and Magnetorheological fields and human body a new challenge for the electromagnetic field computation. International Journal of Computation and Mathematics in Electrical and Electronic Engineering, 2003, Vol. 22, No. 3, 457–469.
  • 6. Sandyk R.: Immediate recovery of cognitive functions and resolution of fatigue by treatment with weak electromagnetic fields in a patient with multiple sclerosis, Int. J. Neurosci., 1997, 90, 59–74.
  • 7. Sandyk R., Therapeutic effects of alternating current pulsed electromagnetic fields in multiple sclerosis. J. Altern. Complement. Med., 1997, 3, 365–386.
  • 8. Sandyk R.: Treatment with AC pulsed electromagnetic fields improves olfactory function in Parkinson`s disease. Int. J. Neurosc., 1999, 97, 225–233.
  • 9. Sieroń A., Biniszkiewicz T., Sieroń K., Biniszkiewicz K.: Subiektywna ocena efektów leczniczych słabych pól magnetycznych, Acta Bio- Optica et Informatica Medica, 1998, 4, 133–137.
  • 10. Sieroń Z.: Applications of magntic field in Medici (Zastosowania pól magnetycznych w medycynie), Alfa Med. Press, Bielsko-Biała 2000.
  • 11. Spur G., Uhlmann E., Patzwald R.: Rheometer for Investigating the Magnetoviscous Effect of Magnetic Fluids, Magnetohydrodynamics, 2001, Vol. 37, No. 3, 279–284.
  • 12. Gadomski A., Bełdowski P., Rubi Miguel P., Urbaniak W., Auge Wayne K., Santamaria-Holek I., Pawlak Z.: Some conceptual thoughts toward nanoscale oriented friction in a model of articular cartilage, Mathematical Biosciences, 2013, 244, 188–200.
  • 13. Rosensweig R. E., Kaiser R., Miskolczy G.: Viscosity of magnetic Fluid, Journal of Colloid and Inference Science, 1969, 4, 680–686.
  • 14. Wierzcholski K.: Tribologie für instabil belastete menschliche Gelenke im magnetischen Feld. International Colloquium of Tribology, Technische Akademie Esslingen, 2004, Vol. III, 1717–1724.
  • 15. Negm A., Lorberg A., Macintyre N. J.: Efficacy of flow frequency pulsed subsensory threshold electric al stimulation vs placebo in pain and physical function in people with knee osteoarthritis:systematic review with meta-analysis. PMIDs:26562074, Osteoarthritis and cartilage 21, 2013, 1281–1289.
  • 16. Wierzcholski K.: Friction forces in human joint for unsymmetrical synovial fluid flow with variable viscosity, magnetic field in curvilinear co-ordinates. Acta of Bioengineering and Biomechanics, 2001, Vol. 3, Suppl. 2, 619–626.
  • 17. Wuschech H., et.al.: Effects of PEMF on Patients With Osteoarthrits:Results of a Prospective,Placebo-Controlled Double-Blind Study. 2015 Willey Periodicals,Inc.Electromagnetics,PMIDs: 23973142; 36: 576–576, pp. 570–585.
  • 18. www.resmedica.com.pl, March 2014.
  • 19. www.eie.com.pl, March 2014.
  • 20. Andersen O. S., Roger E., et.al.: Bilayer thickness and Membrane Protein Function: An Energetic Perspective. Annular Review of Biophysics and Biomolecular Structure. 36 (1), 107–130, doi:10.1146: annuref. biophys.36.040306.132643. Retrieved 12 Decembre 2014.
  • 21. www.tanita.com.
  • 22. Bhushan B.: Nanotribology and nanomechanics of MEMS/NEMS and BioMEMS/BioNEMS materials and devices, Microelectronic Engineering, 2007, 84, pp. 387–412.
  • 23. Cwanek J.: The usability of the surface geometry parameters for the evaluation of the artificial hip joint wear, Rzeszów University Press, Rzeszów 2009.
  • 24. Chagnon G., Rebouah M., Favier D.: Hyperelastic Energy For Soft Biological Tissues: A Review.Journal of Elasticity, 2015, vol. 120, Issue 2, pp. 129–160.
  • 25. Maurel W., Wuy., Thalmann D.: Biomechanical Modells for Soft Tissue Simulation, Springer Verlag Berlin-Heidelberg, 1998.
  • 26. Wierzcholski K.: Pressure distribution in human joint gap for elastic cartilage and time dependent magnetic field. Perm, Russian Journal of Biomechanics, 2003, Vol. 7, No. 1, 24–46.
  • 27. www.fizjoterapia24.pl, March 2014.
Uwagi
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2018).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-29d590b7-e4c7-4fd6-a84d-9f15a18ac823
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.