PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

A new reliable device to assess trunk extensors strength

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
This study aimed to examine the reliability of trunk extensor strength assessment with a functional electromechanical dynamometer (FEMD). Methods: Thirty-one men performed strength assessment at different velocities (V) (V1 = 0.15 m·s−1, V2 = 0.30 m·s-1, V3 = 0.45 m·-1) and range of movement (R) (R1 = 25% cm; R2 = 50% cm), and isometric contraction at 90º. Reliability was obtained through the intraclass correlation coefficient (ICC), typical error (TE), and coefficient of variation (CV). Results: The absolute reliability provided stable repeatability of the average eccentric strength in the V1R1 condition (CV = 9.52%) and the maximum eccentric strength in V1R1 (CV = 9.63%) and V2R2 (CV = 9.66%). The relative reliability of the trunk extensor’s average strength was good (ICC = 0.77–0.83) for concentric and good (ICC = 0.78–0.85) and moderate (ICC = 0.67–0.74) for eccentric contraction. Also, good (ICC = 0.77–0.81) and moderate (ICC = 0.55–0.74) reliability of the maximum strength were obtained for concentric and eccentric contraction. The most reliable manifestation to evaluate the concentric (CV = 11.33%) and eccentric (CV = 9.52%) strength was the average strength in the V1R1 condition and the maximum strength (CV = 10.29%) to isometric assessment. The average concentric strength in the V2R2 condition (r = 0.69) and the maximum eccentric strength in the V1R1 condition (r = 0.65) were the best related to the maximum isometric strength. Conclusion: FEMD is a highly reliable device to evaluate trunk extensors strength.
Słowa kluczowe
Rocznik
Strony
49--57
Opis fizyczny
Bibliogr. 45 poz., rys., wykr.
Twórcy
  • Department of Physical Education and Sport, Faculty of Sport Sciences, University of Granada, Granada, Spain.
  • Exercise and Rehabilitation Sciences Laboratory, School of Physical Therapy, Faculty of Rehabilitation Sciences, Universidad Andres Bello, Santiago, Chile.
  • Department of Physical Education and Sport, Faculty of Sport Sciences, University of Granada, Granada, Spain.
  • Department of Physical Education and Sport, Faculty of Sport Sciences, University of Granada, Granada, Spain.
  • Exercise and Rehabilitation Sciences Laboratory, School of Physical Therapy, Faculty of Rehabilitation Sciences, Universidad Andres Bello, Santiago, Chile.
  • Department of Sports Sciences and Physical Conditioning, Faculty of Education, Universidad Católica de La Santísima Concepción, Concepción, Chile.
  • Department of Sports Sciences and Physical Conditioning, Faculty of Education, Universidad Católica de La Santísima Concepción, Concepción, Chile.
  • Exercise and Rehabilitation Sciences Laboratory, School of Physical Therapy, Faculty of Rehabilitation Sciences, Universidad Andres Bello, Santiago, Chile.
  • Department of Physical Education and Sport, Faculty of Sport Sciences, University of Granada, Granada, Spain.
Bibliografia
  • [1] ARAUJO S., COHEN D., HAYES L., Six weeks of core stability training improves landing kinetics among female capoeira athletes: A pilot study, J. Hum. Kinet., 2015, 45 (1), 27–37.
  • [2] ATKINSON G., NEVILL A.M., Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports Medicine, Sports Med., 1998, 26 (4), 217–238.
  • [3] BARBADO D., LOPEZ-VALENCIANO A., JUAN-RECIO C., MONTERO-CARRETERO C., VAN DIEËN J.H., VERA-GARCIA F.J., Trunk stability, trunk strength and sport performance level in judo, PLoS ONE, 2016, 11 (5), 1–12.
  • [4] BOUILLAND S., LOSLEVER P., LEPOUTRE F.X., Biomechanical comparison of isokinetic lifting and free lifting when applied to chronic low back pain rehabilitation, Med. Bio Eng. Comput., 2002, 40 (2), 183–192.
  • [5] CARUSO J.F., BROWN L.E., TUFANO J.J., The reproducibility of isokinetic dynamometry data, Isokinet. Exerc. Sci., 2012, 20 (4), 239–253.
  • [6] CHO K.H., BEOM J.W., LEE T.S., LIM J.H., LEE T.H., YUK J.H., Trunk muscles strength as a risk factor for nonspecific low back pain: a pilot study, Ann. Rehabil. Med., 2014, 38 (2), 234–240.
  • [7] CLARK B.C., MANINI T.M., MAYER J.M., PLOUTZ-SNYDER L.L., GRAVES J.E., Electromyographic activity of the lumbar and hip extensors during dynamic trunk extension exercise, Arch. Phys. Med. Rehabil., 2002, 83 (11), 1547–1552.
  • [8] COHEN J., Statistical Power Analysis for the Behavioral Sciences, Second Edition, Hillsdale, NJ: Lawrence Erlbaum Associates, Publishers, 1988.
  • [9] DA SILVA R.A., LARIVIÈRE C., ARSENAULT A.B., NADEAU S., PLAMONDON A., Pelvic stabilization and semisitting position increase the specificity of back exercises, Med. Sci. Sports. Exerc., 2009, 41 (2), 435–443.
  • [10] DE BLAISER C., DE RIDDER R., WILLEMS T., DANNEELS L., ROOSEN P., Reliability and validity of trunk flexor and trunk extensor strength measurements using handheld dynamometry in a healthy athletic population, Phys. Ther. Sport, 2018, 34, 180–186.
  • [11] DERVISEVIC E., HADZIC V., BURGER H., Reproducibility of trunk isokinetic strength findings in healthy individuals, Isokinet. Exerc. Sci., 2007, 15, 99–109.
  • [12] DVIR Z., KEATING J., Reproducibility and validity of a new test protocol for measuring isokinetic trunk extension strength, Clin. Biomech., 2001, 16 (7), 627–630.
  • [13] DVIR Z., MÜLLER S., Multiple-joint isokinetic dynamometry: a critical review, J. Strength Cond. Res., 2020, 34 (2), 587–601.
  • [14] FARFAN H.F., GRACOVETSKY S., The Nature of Instability, Spine (Phila Pa 1976), 1984, 9 (7), 714–719.
  • [15] FLOYD W.F., SILVER P.H.S., The function of the erectores spinae muscles in certain movements and postures in man, J. Physiol., 1955, 129 (1), 184–203.
  • [16] GOLUBIĆ A., ŠARABON N., MARKOVIĆ G., Association between trunk muscle strength and static balance in older women, J. Women Aging, 2019, 33 (3), 288–297.
  • [17] GUILHEM G., GIROUX C., COUTURIER A., MAFFIULETTI N.A., Validity of trunk extensor and flexor torque measurements using isokinetic dynamometry, J. Electromyogr. Kinesiol., 2014, 24 (6), 986–993.
  • [18] HOPKINS W.G., Spreadsheets for analysis of validity and reliability, Sport Sci., 2015, 19 (19), 36–44.
  • [19] HOPKINS W.G., Measures of Reliability in Sports Medicine and Science, Sports Med., 2000, 30 (1), 1–15.
  • [20] HOPKINS W.G., MARSHALL S.W., BATTERHAM A.M., HANIN J., Progressive statistics for studies in sports medicine and exercise science, Med. Sci. Sports Exerc., 2009, 41 (1), 3–12.
  • [21] HUPLI M., HURRI H., LUOTO S., SAINIO P., ALARANTA H., Isokinetic performance capacity of trunk muscles, Part I: The effect of repetition on measurement of isokinetic performance capacity of trunk muscles among healthy controls and two different groups of low-back pain patients, Scand. J. Rehabil. Med., 1996, 28 (4), 201–206.
  • [22] JAMES L.P., ROBERTS L.A., HAFF G.G., KELLY V.G., BECKMAN E.M., Validity and reliability of a portable isometric mid-thigh clean pull, J. Strength Cond. Res., 2017, 31 (5), 1378–1386.
  • [23] JANDRE REIS F., RIBERO MACEDO A., Influence of Hamstring Tightness in Pelvic, Lumbar and Trunk Range of Motion in Low Back Pain and Asymptomatic Volunteers during Forward Bending, Asian Spine J., 2015, 9 (4), 535–540.
  • [24] JEREZ-MAYORGA D., CHIROSA RÍOS L.J., REYES A., DELGADO-FLOODY P., MACHADO PAYER R., GUISADO REQUENA I.M., Muscle quality index and isometric strength in older adults with hip osteoarthritis, PeerJ., 2019, 7 (8), e7471.
  • [25] JEREZ-MAYORGA D., DELGADO-FLOODY P., INTELANGELO L., CAMPOS-JARA C., ARIAS-POBLETE L., GARCÍA-VERAZALUCE J., GARCIA-RAMOS A., CHIROSA L.J., Behavior of the muscle quality index and isometric strength in elderly women, Physiol. Behav., 2020, 227, 113145.
  • [26] JEREZ-MAYORGA D., HUERTA-OJEDA Á., CHIROSA-RÍOS L.J., GUEDE-ROJAS F., GUZMÁN-GUZMÁN I.P., INTELANGELO L., MIRANDA-FUENTES C., DELGADO-FLOODY P., Test–Retest Reliability of Functional Electromechanical Dynamometer on Five Sit-to-Stand Measures in Healthy Young Adults, Int. J. Environ., 2021, 18 (13), 6829.
  • [27] JUAN-RECIO C., LÓPEZ-PLAZA D., BARBADO MURILLO D., GARCÍA-VAQUERO M.P., VERA-GARCÍA F.J., Reliability assessment and correlation analysis of 3 protocols to measure trunk muscle strength and endurance, J. Sports Sci., 2017, 36 (4), 1–8.
  • [28] KATO K., HATANAKA Y., The influence of trunk muscle strength on walking velocity in elderly people with sarcopenia, J. Phys. Ther. Sci., 2020, 32 (2), 166–172.
  • [29] KOO T.K., LI M.Y., A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research, J. Chiropr. Med., 2016, 15 (2), 155–163.
  • [30] LARIVIERE C., DA SILVA R.A., ARSENAULT A.B., NADEAU S., PLAMONDON A., VADEBONCOEUR R., Specificity of a Back Muscle Exercise Machine in Healthy and Low Back Pain Subjects, Med. Sci. Sports Exerc., 2010, 42 (3), 592–599.
  • [31] LEE J.H., HOSHINO Y., NAKAMURA K., KARIYA Y., SAITA K., ITO K., Trunk muscle weakness as a risk factor for low back pain: A 5-year prospective study. Spine,1999, 24 (1), 54–57.
  • [32] MACDONALD D.A., LORIMER MOSELEY G., HODGES P.W., The lumbar multifidus: Does the evidence support clinical beliefs?, Man. Ther., 2006, 11 (4), 254–263.
  • [33] MARTINEZ-GARCIA D., RODRIGUEZ-PEREA A., BARBOZA P., ULLOA-DÍAZ D., JEREZ-MAYORGA D., CHIROSA I., RÍOS L.J.C., Reliability of a standing isokinetic shoulder rotators strength test using a functional electromechanical dynamometer: Effects of velocity, PeerJ., 2020, 8, 1–15.
  • [34] MÜLLER J., MÜLLER S., STOLL J., FRÖHLICH K., BAUR H., MAYER F., Reproducibility of maximum isokinetic trunk strength testing in healthy adolescent athletes, Sport. – Sport., 2014, 30 (3), 229–237.
  • [35] NEWMAN B.L., POLLOCK C.L., HUNT M.A., Reliability of measurement of maximal isometric lateral trunk-flexion strength in athletes using handheld dynamometry, J. Sport Rehabil., 2012, 21 (4), 1–5.
  • [36] OLSON M.W., Trunk extensor fatigue influences trunk muscle activities during walking gait, J. Electromyogr. Kinesiol., 2010, 20 (1), 17–24.
  • [37] PANJABI M.M., The stabilizing system of the spine, Part II. Neutral zone and instability hypothesis, J. Spinal Disord., 1992, 5 (4), 390–397.
  • [38] RODRIGUEZ-PEREA A., CHIROSA RÍOS L.J., MARTINEZ-GARCIA D., ULLOA-DÍAZ D., GUEDE ROJAS F., JEREZ-MAYORGA D., CHIROSA RIOS I.J., Reliability of isometric and isokinetic trunk flexor strength using a functional electromechanical dynamometer, PeerJ., 2019, 7, e7883.
  • [39] RODRIGUEZ-PEREA Á., JEREZ-MAYORGA D., GARCÍA-RAMOS A., MARTÍNEZ-GARCÍA D., CHIROSA RÍOS L.J., Reliability and concurrent validity of a functional electromechanical dynamometer device for the assessment of movement velocity, Proc. Inst. Mech. Eng. Part P J. Sport Eng. Technol., 2021, 235 (3), 176–181.
  • [40] ROTH R., DONATH L., KURZ E., ZAHNER L., FAUDE O., Absolute and relative reliability of isokinetic and isometric trunk strength testing using the IsoMed-2000 dynamometer, Phys. Ther. Sport., 2017, 24, 26–31.
  • [41] STEWART A., MARFELL-JONES M., OLDS T., DE RIDDER H., International Society for Advancement of Kinanthropometry, Int. Stand. Anthr. assessment Int. Soc. Adv. Kinanthropometry., Lower Hutt, New Zealand, 2011.
  • [42] SUCHOMEL T.J., NIMPHIUS S., STONE M.H., The Importance of Muscular Strength in Athletic Performance, Sport Med., 2016, 46 (10), 1419–1449.
  • [43] THORSTENSSON A., CARLSON H., ZOMLEFER M.R., NILSSON J., Lumbar back muscle activity in relation to trunk movements during locomotion in man, Acta Physiol. Scand., 1982, 116 (1), 13–20.
  • [44] YANG S., WU W., ZHANG C., WANG D., CHEN C., TANG Y., LI K., XU J., LUO F., Reliability and validity of three isometric back extensor strength assessments with different test postures, J. Int. Med. Res., 2020,48 (2), 300060519885268.
  • [45] ZOUITA A.B.M., ZOUITA S., DZIRI C., BRUGHELLI M., BEHM D.G., CHAOUACHI A., Differences in Trunk Strength Between Weightlifters and Wrestlers, J. Hum. Kinet., 2019, 67 (1), 5–15.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-291d1093-4634-4a76-83dd-8c40ebb16035
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.