Identyfikatory
Warianty tytułu
Stężenie lotnych związków organicznych na terenie hal produkcyjnych w wybranym zakładzie przemysłu meblarskiego
Języki publikacji
Abstrakty
The aim of this study was to determine the concentrations of volatile organic compounds found in the air in five production halls at a furniture manufacturing plant. Tests were performed in production halls, where machining operations were performed both on wood and wood-based materials, in shop halls in which surface- finishing operations were performed, as well as a finished goods warehouse. A Tenax TA synthetic sorbent was used to adsorb compounds found in the air. Volatile substances were analysed by gas chromatography combined with mass spectrometry and thermal desorption. It was found that the microclimate in the examined production halls varied. Differences were observed not only in the type of compounds detected in the shop halls, but also in their amounts. The analysed air contained a broad spectrum of volatile compounds, mainly alcohols, glycols, aromatic hydrocarbons, aldehydes, esters and terpenes. The total concentration of volatile organic compounds (TVOC) found in the air in the examined production halls varied within a very broad range from 795 to 5113 μg/m3. The concentrations of volatile organic compounds identified in the production halls were markedly lower than those specified by Polish legal regulations - the Ordinance of the Minister of Labour and Social Policy of 2002 (with later amendments).
Celem pracy było określenie stężenia lotnych związków organicznych występujących w powietrzu na terenie pięciu hal produkcyjnych w zakładzie przemysłu meblarskiego. Badaniu poddano hale, w których przeprowadzano zarówno obróbkę mechaniczną drewna i tworzyw drzewnych, jak i hale, w których wykonywano operacje uszlachetniania powierzchni oraz magazyn wyrobów gotowych. Adsorpcję związków obecnych w powietrzu przeprowadzano na sorbencie syntetycznym Tenax TA. Lotne substancje analizowano techniką chromatografii gazowej w połączeniu ze spektrometrią mas i termiczną desorpcją. Stwierdzono, że mikroklimat badanych hal produkcyjnych był zróżnicowany, tak pod względem rodzaju, jak ilości występujących w nich związków. Całkowite stężenie lotnych związków organicznych zmieniało się w bardzo szerokim zakresie, od 795 do 5113 μg/m3. W badanym powietrzu występowały głównie związki należące do alkoholi, glikoli, węglowodorów aromatycznych, aldehydów estrów i terpenów. Stężenie zidentyfikowanych w halach produkcyjnych lotnych związków organicznych kształtowało się na zdecydowanie niższym poziomie niż to regulują polskie przepisy prawne, rozporządzenie Ministra Pracy i Polityki Socjalnej z 2002 roku (z późniejszymi zmianami).
Rocznik
Tom
Strony
33--50
Opis fizyczny
Bibliogr. 30 poz., rys., tab.
Twórcy
autor
- Poznan University of Life Sciences, Poznan, Poland
autor
- Poznan University of Life Sciences, Poznan, Poland
Bibliografia
- 1. AgBB (Ausschuss zur gesundheitlichen Bewertung von Bauprodukten) [2012]: Health-related Evaluation of Emissions of Volatile Organic Compounds (VOC and SVOC) from Building Products
- 2. Andersson K., Bakke J.V., Bjørseth O., Bornehag C.G., Clausem G., Hongslo J. K., Kjellman M., Kjaegaard S., Levy F., Mølhave L., Skerfving S., Sundell J. [1997]: TVOC and Health in Non-industrial Indoor Environments. Indoor Air 7 [2]: 78–91
- 3. Brinke J.T., Selvin S., Hodgson A.T., Fisk W.J., Mendell M.J., Koshland C.P., Daisey J.M. [1998]: Development of new volatile organic compound (VOC) exposure metrics and their relationship to “Sick Building Syndrome” symptoms. Indoor Air8 [3]: 140–152
- 4. Brown S.K., Sim M.R., Abramson M.J., Gray C.N. [1994]: Concentrations of volatile organic compounds in indoor air: a review. Indoor Air 4 [2]: 123–134
- 5. ChemSpider. Search and share chemistry [2013]: http://www.chemspider.com/ [July 2013]
- 6. Eklund B.M., Burkes S., Morris P., Mosconi L. [2008]: Spatial and temporal variability in VOC levels within a commercial retail building. Indoor Air 18 [5]: 365–374
- 7. Guo H., Murray F., Lee S.C. [2003]: The development of a low volatile organic compound emission house-a case study. Building and Environment 38 [12]: 1413–1422 http://www.umweltbundesamt.de/produkte-e/bauprodukte/archive/agbb_evaluation_scheme_2012.pdf
- 8. Interdepartmental Commission for Maximum Admissible Concentrations and Intensities for Agents Harmful to Health in the Working Environment [2013]:http://www.ilo.org/safework/info/WCMS_151579/lang--en/index.htm [July 2013]
- 9. Kirkeskov L., Witterseh T., Funch L.W., Kirstiansen E., Mølhave L., Hansen M.K., Kundsen B.B. [2009]: Health evaluation of volatile organic compound (VOC) emission from exotic wood products. Indoor Air 19 [1]: 45–57
- 10. Krause C., Mailahn W., Nagel R., Schulz C., Seifert B., Ullrich D. [1987]: Occurrence of volatile organic compounds in the air of 500 homes in Germany. Proceedings of the Fourth International Conference on Indoor Air Quality and Climate, vol. 1. West Berlin, Germany. Institute for Water, Soil and Air Hygiene: 102–106
- 11. Lee JH., Seung M.H., Dai W.L., Gwi S.H. [2002]: Determination of volatile organic compounds (VOCs) using Tedlar bag/solid-phase microextraction/ gas chromatography/mass spectrometry (SPME/GC/MS) in ambient and workplace air. Bulletin of the Korean Chemical Society 23 [3]: 488–496
- 12. Loh M.M., Houseman E.A., Gray, G.M., Levy J.I., Spengler J.D., Bennet D.H. [2006]: Measured concentrations of VOCs in several non-residential microenvironments in the United States. Environmental Science & Technology 40 [22]: 6903–6911
- 13. Material Safety Data Sheets - Pharmco-Aaper [2013]: http://www.pharmcoaaper.com/pages/MSDS/MSDS_B/butyl_ether.pdf [July 2013]
- 14. Mølhave L. (2003): Organic compounds as indicators of air pollution. Indoor Air 13 [6]: 12–19
- 15. Nielsen G.D., Larsen S.T., Olsen O., Løvik M., Poulsen L.K., Glue C., Wolkoff P. [2007]: Do indoor chemicals promote the development of airway allergy? Indoor Air 17[3]: 236–255
- 16. Ohlmeyer M., Makowski M., Fried H., Hasch J., Schöler M. [2008]: Influence of panel thickness on the release of volatile organic compounds from OSB made of Pinus sylvestris L. Forest Products Journal 58 [1/2]: 65–70
- 17. PAN Pesticides Database: Chemical Active Ingredient Search [2013]: http://www.pesticideinfo.org/Search_Chemicals.jsp [July 2013]
- 18. Roffael E. [2006]: Volatile organic compounds and formaldehyde in nature. wood and wood based panels. Holz als Roh- und Werkstoff. 64 [2]: 144–149
- 19. Rozporządzenie Ministra Pracy i Polityki Społecznej z dnia 29 listopada 2002 r. w sprawie najwyższych stężeń i natężeń czynników szkodliwych dla zdrowia w środowisku pracy (Dz. U. Nr 217, poz. 1833, z 2005 r. Nr 212, poz. 1769, z 2007 r. Nr 161, poz. 1142, z 2009 r.Nr 105, poz. 873, z 2010 r. Nr 141, poz. 950)
- 20. Rufus D.E., Jurvelina J., Koistinena K., Saarelad K., Jantunene M. [2001a]: VOC source identification from personal and residential indoor, outdoor and workplace microenvironment samples in EXPOLIS-Helsinki, Finland. Atmospheric Environment35 [28]: 4829–4841
- 21. Rufus D.E., Jurvelin J., Saarela K., Jantunen M. [2001b]: VOC concentrations measured in personal samples and residential indoor, outdoor and workplace microenvironmentsin EXPOLIS-Helsinki, Finland. Atmospheric Environment 35 [28]: 4829–4841
- 22. Salthammer T. [1997]: Emission of Volatile Organic Compounds from Furniture Coatings. Indoor Air 7 [3]: 189–197
- 23. Salthammer T., Schwarz A., Fuhrmann F. [1999]: Emission of reactive compounds and secondary products from wood-based furniture coatings. Atmospheric Environment33 [1]: 75–84
- 24. Stachowiak-Wencek A. [2012]: Emission of volatile organic compounds (VOC) from polyurethane lacquers used in furniture production. Physico-chemical analysis of lignocellulosic materials Part II. WULS-SGGW Press: 44–54
- 25. Stachowiak-Wencek A., Prądzyński W. [2011]: Emission of volatile organic compounds (VOC) from waterborne lacquers with different contents of solids. Drewno54 [186]: 51–63
- 26. The National Institute for Occupational Safety and Health (NIOSH) [2013]:http://www.cdc.gov/NIOSH/ [July 2013]
- 27. Wallace L., Pellizzari E., Wendel C. [1991]: Total organic concentrations in 2700 personal, indoor and outdoor samples collected in the US EPA TEAM studies. Indoor Air1 [4]: 465–477
- 28. Wargocki P., Wyon D.P., Bajk Y.K., Clausen G., Fanger P.O. [1999]: Perceived air quality, sick building syndrome (SBS) symptoms and productivity in an office with two different pollution loads. Indoor Air 9 [3]: 165–179
- 29. Wiglusz R. [2000]: Zanieczyszczenie powietrza w budynkach substancjami chemicznymi. Praktyka Budowlana 12: 100–102
- 30. Wu C.H., Feng C.T., Lo Y.S., Lin T.Y., Lo J.G. [2004]: Determination of volatile organic compounds in workplace air by multisorbent adsorption/thermal desorption-GC/MS. Chemosphere 56 [1]: 71–80
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-26dff946-e2a6-4e7b-88e1-744e258b2140