PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Determination of Energy Absorption on Seat Regions of Footwear for the Obese

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Określenie absorpcji energii w przypadku obuwia dla otyłych
Języki publikacji
EN
Abstrakty
EN
Ideal footwear with a design configuration is necessitated as a tool of rehabilitation to render therapeutic benefits, especially for obese individuals who are experiencing greater risk during locomotion. Energy absorption is found to depend on variables like heel height, slope angle and load exerted by the body mass index. Statistical analysis was carried out to formulate a predictive equation for absorbed energy. It was found that a heel height of 30 mm offers an optimum base for further design of footwear. A coefficient of determination (R2) with a value of 0.933 indicates that the model fits the experimental data nicely. Hence, 30 mm 20 degree is suggested for designing ideal footwear as it enables load dissipation and energy absorption to render foot-comfort benefits and advantages to the user.
PL
Zaprojektowanie idelanego obuwia jest niezbędne jako skuteczne narzędzie rehabilitacji osób otyłych. Stwierdzono, że absorpcja energii w obuwiu zależy od zmiennych, takich jak: wysokość pięty, kąt nachylenia oraz obciążenie wywierane przez wskaźnik masy ciała. Przeprowadzono analizę statystyczną, aby sformułować równanie predykcyjne dla pochłoniętej energii. Stwierdzono, że wysokość obcasa 30 mm stanowi optymalną podstawę do dalszego projektowania obuwia. Współczynnik determinacji (R2) o wartości 0,933 wskazuje, że model pasuje do danych eksperymentalnych. Stwierdzono, że 30 mm wysokości obcasa i kąt nachylenia 20 stopni są optymalne do zaprojektowania idealnego obuwia. Dobór takich parametrów umożliwia dobre rozpraszanie obciążenia i pochłanianie energii zapewniając tym samym komfort użytkowania.
Słowa kluczowe
Rocznik
Strony
76--80
Opis fizyczny
Bibliogr. 18 poz., rys., tab.
Twórcy
  • Central Leather Research Institute, Chennai, 600020, India
  • Central Leather Research Institute, Chennai, 600020, India
  • Anna University, Chennai, 600025, India
Bibliografia
  • 1. Alridge T. Am F am Phys. 2004; 70: 332-338.
  • 2. Spencer S. Cochrane Database Syst Rev. 2000; 3, CD002302.
  • 3. Hutchins S, Bowker P, Geary N, Richards J. Foot (Edinb), 2009; Sept. 19(3), Epub, 28 2009; Feb: 165-70.
  • 4. Geary Npj., Klenerman L., Proceedings of the Conference at Nene College, Northants, UK, (1986), 161-73.
  • 5. Nawoczenski DA., Birke JA., Coleman WC. J Am Podiatr Med Assoc. 1988; 78: 455-460.
  • 6. Mueller MJ, Zou D, Lott DJ. Diabetes Care 2005; 28(12): 2908-2912.
  • 7. Janisse DJ. ClinPodiatr Med Surg 1995; 1: 41–61.
  • 8. Mathivanan S, Gautham Gopalakrishna Das BN, Jagathnath Krishna. Applied Mechanics and Materials, Trans Tech Publications, 749.
  • 9. Villa A., Andescon Conference, IEEE, (Sep 2010), 1-4
  • 10. Praet SF, Louwerens JW. Diabetes Care, 26(2) (Feb. 2003), 441-5.
  • 11. Janisse DJ., Janisse EJ. AmAcadOrthop Surg. 2008; Mar.16(3): 152-8.
  • 12. Menz HB., Lord SR., Journal of the American Podiatric Medical Association 1999; 89, 3: 458–461.
  • 13. Helland AE. Tyurkiye Klinikeri J PM&R, Special Topics 2010; 3(2): 107-13.
  • 14. Cavanagh PR. Foot Ankle 1987; 7: 262-276.
  • 15. Munderman. Osteoarthritis and Cartilage 2004; 12(50): 389-399.
  • 16. Marcelo P, De Castro, Sofia C.Abreu, Helena Sousa, Leandro Machado, Rubim Santos, Joao Paulo Vilas- Boas. Research Quarterly for Exercise and Sport. 2014; 85(20: 188-197.
  • 17. Steffen Mueller, Anja Carlsohn, Juliane Mueller, Heiner Baur, Frank Mayer. Plos One 2016; 11(2).
  • 18. Karen J Mickle, Julie R Steele. Gait & Posture 2015; 42(4): 442-447.
Uwagi
PL
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2019).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-25889b98-1d38-4abd-a885-ae8a063880d3
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.