PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Safety aspects for the R290 (propane) as working medium in small air conditioning installations

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Following the entry into force of the Regulation (EU) No 517/2014 of the European Parliament and of the Council of 16 April 2014 on fluorinated greenhouse gases and repealing Regulation (EC) No 842/2006, the scope of refrigerants, which have so far been commonly used is very limited. All preferred refrigerants are mostly flammable and explosive, and they include R32, R1234yf, R1234ze, R290 (propane), R600a (isobutane), R717 (ammonia). However, it should be noted that refrigerants such as R32, R1234yf, R1234ze are classified as mildly flammable and has been created for them, in accordance with ISO 817 standard, special group called A2L. It is also worth noting that the new classification moved ammonia to the group B2L - that means is toxic and mildly flammable. The article focuses on defining the conditions in which there is possible to build safely split installation in which the propane is a refrigerant. It turns out that small splits are devices which can be used safely with R290 in most cases.
Słowa kluczowe
Rocznik
Tom
Strony
22--29
Opis fizyczny
Bibliogr. 27 poz., rys., tab.
Twórcy
  • Faculty of Power and Aeronautical Engineering, Warsaw University of Technology, Warsaw, Poland
  • Faculty of Power and Aeronautical Engineering, Warsaw University of Technology, Warsaw, Poland
  • Faculty of Power and Aeronautical Engineering, Warsaw University of Technology
Bibliografia
  • 1. Bartela, L., Skorek-Osikowska, A. & Kotowicz, J. An analysis of the investment risk related to the integration of a supercritical coal-fired combined heat and power plant with an absorption installation for CO2 separation. Applied Energy 156, 423–435 (2015).
  • 2. Baryłka, A. The impact of fire on changing the strngth of the underground shelter structure. Rynek Energii 146, 71–75 (1 2020).
  • 3. Bohdal, T., Charun, H. & Sikora, M. Empirical study of heterogeneous refrigerant condensation in pipe minichannels. International Journal of Refrigeration 59, 210–223 (2015).
  • 4. Bohdal, T., Widomska, K. & Sikora, M. The analysis of thermal and flow characteristics of the condensation of refrigerant zeotropic mixtures in minichannels. Archives of Thermodynamics 37, 41–69 (2 2016).
  • 5. BRA: Guide to Flammable Refrigerants (2012).
  • 6. Colbourne, D. & Huhren, R. Operation of split air conditioning systems with hydrocarbon refrigerant. A conversion guide for technicians, trainers and engineers. Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ) GmbH - German International Cooperation -Programme Proklima (Eschborn, Germany, 2011).
  • 7. Cyklis, P. Two stage ecological hybrid sorption-compression refrigeration cycle. International Journal of Refrigeration 48, 121–131 (2014).
  • 8. Dz.U. 2010 nr 138 poz. 931. Rozporządzenie Ministra Gospodarki z dnia 8 lipca 2010 r. w sprawie minimalnych wymagań, dotyczących bezpieczeństwa i higieny pracy, związanych z możliwością wystąpienia w miejscu pracy atmosfery wybuchowej
  • 9. EN 378: Refrigerating systems and heat pumps — Safety and environmental requirements
  • 10. Gourbi, A., Bousmaha, I., Brahami, M. & Tilmatine, A. Numerical Study of a Hybrid Photovoltaic Power Supply System. Journal of Power Technologies 96, 137–144 (2 2016).
  • 11. Grzebielec, A. Europa zmierza w kierunku naturalnych czynników chłodniczych. Chłodnictwo 9, 42–46 (2010).
  • 12. Grzebielec, A. & Rusowicz, A. Kierunki rozwoju syntetycznych czynników chłodniczych w Europie. Polska Energetyka Słoneczna 1-4, 45–49 (2012).
  • 13. Harmanti, N., Folic, R., Magyar, Z., Drazic, J. & Kurtowic-Folic, N. Building envelope influence on the annual energy performance in office buildings. Thermal Science 20, 679–693 (2 2016).
  • 14. Honeywell. Solstice ze refrigerant (HFO-1234ze). The Environmental Alternative to traditional refrigerants (2014).
  • 15. Kukfisz, B., Półka, M. & Salamonowicz Z. and Woliński, M. Badania inertyzacji mieszanin pyłowo powietrznych. Przemysł Chemiczny 93, 103–106 (1 2014).
  • 16. Laskowski, R. Relations for steam power plant condenser performance in off-design conditions in the function of inlet parameters and those relevant in reference conditions. Applied Thermal Engineering 103, 528–536 (2016).
  • 17. Owczarek, M., Owczarek, S., Baryłka, A. & Grzebielec, A. Measurement Method of Thermal Diffusivity of the Building Wall for Summer and Winter Seasons in Poland. Energies 14. ISSN: 1996-1073 (2021).
  • 18. Rozporządzenie Parlamentu Europejskiego i Rady (UE) nr 517/2014 z dnia 16 kwietnia 2014 r. w sprawie fluorowanych gazów cieplarnianych i uchylenia rozporządzenia (WE) nr 842/2006
  • 19. Rucinski, A., Rusowicz, A., Grzebielec, A. & Jaworski, M. Wycofywanie czynników chłodniczych i ich bezpieczna utylizacja. Logistyka 1, 116–22 (2016).
  • 20. Ruciński, A., Rusowicz, A. & Grzebielec, A. Czynniki chłodnicze w transporcie samochodowym - aspekty prawne i techniczne. Logistyka 5, 1303–1309 (2014).
  • 21. Rusowicz, A., Grzbielec, A. & Ruciński, A. Ocena zagrożeń związanych z wykorzystywaniem naturalnych czynników chłodniczych. Logistyka 5, 1310–1316 (2014).
  • 22. Rusowicz, A. & Grzebielec, A. Aspekty prawne i techniczne zmiany czynników chłodniczych w instalacjach chłodniczych i klimatyzacyjnych. Czasopismo Inżynierii Lądowej, Środowiska i Architektury, JCEEA 32, 359–367 (62 2015).
  • 23. Smierciew, K., Butrymowicz, D., Kwidzyński, R. & Przybyliński, T. Analysis of application of two-phase injector in ejector refrigeration systems for isobutane. Applied Thermal Engineering 78, 630–639 (2015).
  • 24. Spatz, M. & Minor, B. HFO-1234yf A Low GWP Refrigerant For MAC in. Honeywell / DuPont Joint Collaboration. SAE World Congress - Detroit, Michigan, April 14-17 (2008).
  • 25. Szczucka-Lasota, B. Opracowanie stanowiska do przeprowadzenia testów korozyjnych. Aparatura Badawcza i Dydaktyczna 19, 303–308 (2014).
  • 26. Szwast, M. & Szwast, Z. A Mathematical Model of Membrane Gas Separation with Energy Transfer by Molecules of Gas Flowing in a Channel to Molecules Penetrating this Channel from the Adjacent Channe. Chemical and Process Engineering 36, 151–169 (2 2015).
  • 27. The Japan Society of Refrigerating and Air Conditioning Engineers: Risk Assessment of Mildly Flammable Refrigerants, April 2014.
Uwagi
Opracowanie rekordu ze środków MNiSW, umowa Nr 461252 w ramach programu "Społeczna odpowiedzialność nauki" - moduł: Popularyzacja nauki i promocja sportu (2021).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-23797638-6df5-4236-8269-ffe76e1108a7
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.