ORC power plant operating with wet working fluid powered by biomass-fired boiler

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Siłownia ORC pracująca z mokrym czynnikiem roboczym zasilana z kotła wodnego opalanego biomasą
Języki publikacji
EN
Abstrakty
EN
In the paper has been performed the analysis of vapour power plant operating with wet working fluid. Considered vapour power plant operates according to the comparative Clausius-Rankine cycle and is powered by biomass energy. The analysis of the system, based on the results of the heat-flow calculations, was performed for three wet working fluids: acetone, R1234ze- (Z), R142b. The calculations, which goal was to mainly the power and efficiency of Clausius-Rankine cycle, were performed for four temperature of superheated vapour of working medium: Tn1 = 115, 125, 135, 145˚C. Tabulated calculations results were the basis for the implementation of graphs and to formulate final conclusions. Calculations were made using EES program (Engineering Equation Solver).
PL
W artykule przedstawiono analizę efektywności pracy siłowni parowej pracującej z mokrym czynnikiem roboczym. Rozpatrywana siłownia pracuje według obiegu porównawczego Clausiusa-Rankine’a i jest zasilana energią biomasy. Analiza systemu bazująca na wynikach obliczeń cieplno-przepływowych została wykonana dla trzech mokrych czynników roboczych: acetonu, czynnika R1234ze(Z) i R142b. Obliczenia, których celem było głównie uzyskanie wartości mocy i sprawności obiegu Clausiusa-Rankine’a, zostały wykonane dla czterech wartości temperatury pary przegrzanej czynnika roboczego równych: Tn1 = 115, 125, 135, 145˚C. Wyniki obliczeń zestawione w tabeli były podstawą do wykonania wykresów oraz sformułowania wniosków końcowych. Obliczenia wykonano w programie EES (Engineering Equation Solver).
Czasopismo
Rocznik
Tom
Strony
16--20
Opis fizyczny
Bibliogr. 7 poz., rys., tab., wykr.
Twórcy
autor
  • West Pomeranian University of Technology, Szczecin, ORC Power Plants Research and Development Centre, Szczecin
  • West Pomeranian University of Technology, Szczecin, ORC Power Plants Research and Development Centre, Szczecin
Bibliografia
  • [1] Liu H., Qiu G.Q., Shao Y.J., Daminabo F., Riffat S.B., Preliminary experimental investigations of a biomass-fired micro-scale CHP with organic Rankine cycle, International Journal of Low-Carbon Technologies, 5 (2010), pp. 81-87
  • [2] Erhart T., Strzalka R.., Eicker U., Infield D., Performance Analysis of a Biomass ORC Polygeneration System, 2nd European Conference on Polygeneration - 30th March-1st April, 2011- Tarragona, Spain, pp. 1-11
  • [3] Qiu G.Q., Shao Y., Li J., Liu H., Riffat S.B., Experimental investigation of biomass-fired ORC-based micro-CHP for domestic applications, Fuel 96 (2012), pp. 374-382
  • [4] Nowak W., Borsukiewicz-Gozdur A., Siłownie ORC sposobem na wykorzystanie energii ze źródeł niskotemperaturowych, Czysta Energia - nr 2/2011
  • [5] Badr O., O’Callaghan W.P., Probert S.D.: Thermodynamic and Thermophisical Properties of Organic Working fluids for Rankinecycle Engine, Applied Energy 19, 1985, pp. 1-40.
  • [6] Aghahosseini S., Dincer I., Comparative performance analysis of low-temperature Organic Rankine Cycle (ORC) using pure and zeotropic working fluids, Applied Thermal Engineering 54 (2013), pp. 35-42
  • [7] Gao P., Jiang L., Wang L.W., Wang R.Z., Song F.P., Simulation and experiments on an ORC system with different scroll expanders based on energy and exergy analysis, Applied Thermal Engineering 75 (2015), pp. 880-888