PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Influence of Surface Modification on Properties of Stainless Steel Used for Implants

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Wpływ modyfikacji powierzchni na właściwości stali nierdzewnej stosowanej na implanty
Języki publikacji
EN
Abstrakty
EN
The aim of the study was assessment of the influence of stainless steel 316 LVM surface modification on its functional properties. The analyzed steel undergone a surface treatment consisting of the following processes: mechanical polishing, chemical passivation and deposition of Al2O3 layers by Atomic Layer Deposition method. The proposed variant of surface treatment will undoubtedly contribute to improving the functional properties of stainless steel intended for implants. In order to assess functional properties of the steel, electrochemical studies, adhesion (scratch test), wetting angle tests and topography of surface (AFM method) were performed. The obtained results of the study showed clearly that the proposed by the authors way of surface treatment including: mechanical polishing, chemical passivation and deposition of Al2O3 layer by means of the ALD method effectively improves the corrosion resistance of stainless steel.
PL
Celem pracy była ocena wpływu modyfikacji powierzchni stali nierdzewnej 316 LVM na jej właściwości funkcjonalne. Obróbka powierzchni składała się z następujących procesów: polerowanie mechaniczne, chemiczna pasywacja i naniesienie warstw Al2O3 metodą ALD (Atomic Layer Deposition). Zaroponowany wariant obróbki powierzchni niewątpliwie przyczyni się do poprawy właściwości funkcjonalnych stali przeznaczonej na implanty. W celu oceny właściwości funkcjonalnych stali przeprowadzono badania elektrochemiczne, badania adhezji warstw (scratch test), oraz badania zwilżalności (kąt zwilżania i badania topografii powierzchni metodą AFM). Uzyskane wyniki badań wykazały wyraźnie, że zaproponowany przez autorów sposób obróbki powierzchni, w tym: polerowanie mechaniczne, pasywacja chemiczna i naniesienie warstw Al2O3 metodą ALD skutecznie poprawia odporność na korozję stali nierdzewnej.
Twórcy
autor
  • Silesian University of Technology, Faculty of Biomedical Engineering, 40 Roosevelta Str., 41-800 Zabrze, Poland
autor
  • Silesian University of Technology, Faculty of Mining and Geology, 2 Akademicka Str., 44-100 Gliwice, Poland
autor
  • Silesian University of Technology, Faculty of Biomedical Engineering, 40 Roosevelta Str., 41-800 Zabrze, Poland
autor
  • Silesian University of Technology, Faculty of Biomedical Engineering, 40 Roosevelta Str., 41-800 Zabrze, Poland
autor
  • Silesian University of Technology, Faculty of Biomedical Engineering, 40 Roosevelta Str., 41-800 Zabrze, Poland
autor
  • Silesian University of Technology, Faculty of Mining and Geology, 2 Akademicka Str., 44-100 Gliwice, Poland
Bibliografia
  • [1] J. Marciniak, Biomaterials, Silesian University of Technology, Gliwice 2002.
  • [2] A. S. Hamdy, D. P. Butt, A.A. Ismail, Electrochim. Acta 52 3310 (2007).
  • [3] Z. P. Yao, Z. H. Jiang, F. P. Wang, Electrochim. Acta 52 4539 (2007).
  • [4] T. Lampke, A. Leopold, D. Dietrich, G. Alisch, B. Wielage, Surf. Coat.Technol. 201 3510 (2006).
  • [5] G. Gusmano, G.Montesperelli,M. Rapone,G. Padeletti, A.Cusma, S.Kaciulis, A. Mezzi, R. Maggio, Surf. Coat. Technol. 201, 5822 (2007).
  • [6] H. Y. Liu, L. Gao, J. Am. Ceram. Soc. 88, 1020 (2005).
  • [7] I. M. Kusoglu, E. Celik, H. Cetinel, I. Ozdemir, O. Demirkurt, K. Onel, Surf. Coat. Technol. 200, 1173 (2005).
  • [8] M. Miyauchi, A. Nakajima, K. Hashimoto, T. Watanabe, Adv. Mater. 12, 1923 (2000).
  • [9] J. Szewczenko, J. Jaglarz, M. Basiaga, J. Kurzyk, Z. Paszenda Opt. Appl. 43, 1, 173-180 (2013).
  • [10] D. R. Yan, J. N. He, X. Z. Li, Y. Liu, J. X. Zhang, H. L. Ding, Surf. Coat. Technol. 141 1 (2001).
  • [11] F. T. Cheng, P. Shi, H.C. Man, Scr. Mater. 51, 1041 (2004).
  • [12] M. Basiaga, Z. Paszenda, W. Walke, P. Karasiński, J. Marciniak. Information Technologies in Biomedicine. Advances in Intelligent Systems and Computing 284, 411-420, Springer (2014).
  • [13] M. Basiaga, W. Walke, Z. Paszenda, P. Karasiński, J. Szewczenko. Biomatter 4, 1, (2014).
  • [14] W. Walke, Z. Paszenda, M. Basiaga, P. Karasiński, M. Kaczmarek. Information Technologies in Biomedicine. Advances in Intelligent Systems and Computing 284, 403-410, Springer (2014)
  • [15] J. Szewczenko, J. Jaglarz, M. Basiaga, J. Kurzyk, E. Skoczek, Z. Paszenda Electrical Review 88, 228 (2012).
  • [16] W. Kajzer, A. Kajzer: Electrical Review 12, 275 (2013).
  • [17] J. Marciniak, J. Szewczenko, W. Walke, M. Basiaga, M Kiel, I Mańka. Information Technologies in Biomedicine, Springer ASC 47, (2008) 529-536
  • [18] R. Matero, M. Ritala, M. Leskelä, T. Salo, J. Aromaa, O. Forsén, J. Phys. IV France 09 493 (1999).
  • [19] C.X. Shan, X. Hou, K.L. Choy, Surf. Coat. Technol. 202, 2399 (2008).
  • [20] E. Marin, A. Lanzutti, L. Guzman, L. Fedrizzi, J. Coat. Technol. Res. 1 (2011) .
  • [21] L. Blacha, G. Siwiec, B. Oleksiak, Metalurgija 52, 301 (2013).
  • [22] L. Blacha, Archives of Metallurgy and Materials 50, 989 (2005).
  • [23] M. Otto, M. Kroll, T. Ksebier, R. Salzer, R.B Wehrspohn, Energy Procedia 27 361 (2012).
  • [24] M. Cote, Ch. Doillon, Biomaterials 13, 612 (1992).
  • [25] M. Karłowska, Dental Prosthetics 2 135 (2005).
Uwagi
PL
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-21dae15a-b6aa-49d4-b9bd-b19bb4c6c3a6
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.