PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Glare assessment for research and development of measurement methods

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Ocena olśnienia dla badań i rozwoju metod pomiarowych
Języki publikacji
EN
Abstrakty
EN
Glare is one of the most important parameter of lighting quality. Despite the passage of time from the beginning of glare research, no standard of conducting laboratory experiments was proposed. In the article the review of solutions related to glare assessment is presented. The method of conducting research on glare is also described. The authors pay attention to the most important aspects in the methodology of glare assessment for the experimental research on glare and glare assessment based on UGR measurements. The tests of the new algorithm for UGR calculation is presented — algorithm for precise identification and extraction of glare source area from HDR image.
PL
Olśnienie jest jednym z najważniejszych parametrów jakości oświetlenia. Pomimo upływu czasu od rozpoczęcia badań nad olśnieniem, nie zaproponowano żadnego standardu prowadzenia eksperymentów laboratoryjnych. W artykule przedstawiono przegląd rozwiązań związanych z oceną olśnienia. Została także opisana metoda prowadzenia badań nad olśnieniem. Autorzy zwracają uwagę na najważniejsze aspekty metodyki oceny olśnienia w badaniach eksperymentalnych nad olśnieniem oraz metodyki oceny olśnienia w oparciu o pomiar UGR. Przedstawiono testy nowego algorytmu wyznaczania wskaźnika UGR; algorytmu precyzyjnego wyodrębniania obszaru źródła olśnienia na obrazie HDR.
Rocznik
Strony
169--176
Opis fizyczny
Bibliogr. 87 poz., rys.
Twórcy
  • Warsaw University of Technology, Institute of Theory of Electrical Engineering, Measurement and Information Systems, Warsaw, Poland
  • Central Institute for Labour Protection - National Research Institute (CIOP-PIB), Warsaw, Poland
  • TechnoTeam Bildverarbeitung GmbH, 98693 Ilmenau, Germany
Bibliografia
  • [1] Wolska A., Glare as specific factor in the working environment. Przegląd Elektrotechniczny, 89 (2013), n.1a, 142-144
  • [2] Light and lighting. Lighting of Work Places. Part 1. Indoor Work Places. European Standard. EN 12464-1: 2011. European Committee for Standardization (CEN), Brussels
  • [3] CIE, Discomfort glare in the interior working environment. CIE Publication No 55 International Commission on Illumination (CIE). Vienna 1983
  • [4] CIE, Discomfort Glare in Interior Lighting. CIE Publication No 117 (TC 3–13). International Commission on Illumination (CIE). Vienna 1995
  • [5] Parsons J.H., Glare, its causes and effects. The Illuminating Engineer, 1910, 3, 99-103
  • [6] Holladay, L.L., The fundamentals of glare and visibility. J.Opt. Soc. Amer. 1926, n.12, 271-319
  • [7] Hopkinson R.G., Bradley R.C., A study of glare from very large sources. Illum Eng. 55 (1960), n.5, 288-94
  • [8] Petherbridge P, Hopkinson RG. 1950. Discomfort glare and the lighting of buildings. IESTrans. XV (1950), n.2, 39-79
  • [9] Hopkinson R.G., The multiple criterion technique of subjective appraisal, Quarterly Journal of Experimental Psychology, 1950, n.2,3, 124-131
  • [10] Hopkinson R.G., Evaluation of glare. Illum Eng. 52 (1957), n.6, 305-316
  • [11] Hopkinson R.G., Glare from daylighting in buildings. Appl Ergon. 1972, n.3, 206-215
  • [12] De Boer J.B., Visual perception in road traffic and the field of vision of the motorists. In: Public Lighting (de Boer J,B, ed.) Philips Technical Library, Eindhoven 1967. pp.11-96
  • [13] De Boer J.B., Quality criteria for the passing beam of motocar headlights. Presented at the GTB Meeting in Walldorf, West Germany, 1973
  • [14] Carlucci S., Causone F., De Rosa F., Pagliano L. A review of indices for assessing visual comfort with a view to their use in optimization processes to support building integrated design. Renewable and Sustainable Energy Reviews. 47 (2015), 1016-1033
  • [15] Sawicki D., Wolska A., The unified semantic glare scale for GR and UGR indexes, Proc. of the 2016 IEEE Lighting Conference of the Visegrad Countries (Lumen V4), 13-16.09.2016 Karpacz, Poland
  • [16] Summers A.J. Lighting and the Office Environment: A Review. Australian Journal of Physiotherapy, 35 (1989), Issue 1, 15-24
  • [17] Clear R.D., Discomfort glare: what do we actually know? Lighting Research & Technology, 45 (2013), n.2, 141-158
  • [18] Pierson C., Wienold J., Bodart M. Review of Factors Influencing Discomfort Glare Perception from Daylight. LEUKOS The Journal of the Illuminating Engineering Society. 14 (2018), Issue 3, 111-148
  • [19] Paul B. The assessment of light sources, 1997, M.Sc Thesis, University of Cape Town, South Africa
  • [20] Paul B, Einhorn H.D., Discomfort glare from small light sources, Lighting Research & Technology, 31 (1999), n.4, 139-144
  • [21] Osterhaus W.K.E., Bailey L.L., Large area glare sources and their effect on visual discomfort and visual performance at computer workstations. Conference: Industry Applications Society Annual Meeting, 1992., Conference Record of the 1992 IEEE DOI: 10.1109/IAS.1992.244537
  • [22] Hopkinson R.G., Collins W.M., An Experimental Study of the Glare from a Luminous Ceiling, Transactions of the Illuminating Engineering Society (London), Lighting Research & Technology 28 (1963), n.4, 142-148
  • [23] Fekete J., Sik‐Lányi C., Schanda J., Spectral discomfort glare sensitivity investigations, Ophthalmic & Physiological Optics, 30 (2010), n.2, 182-187
  • [24] Flannagan M.J., Subjective and objective aspects of headlamp glare: effects of size and spectral power distribution, 1989, The University of Michigan Transportation Research Institute Ann Arbor, Michigan 48109-2150, U.S.A. Report No. UMTRI-99-36
  • [25] Guth S.K., Comfortable brightness relationships for critical and casual seeing, Illuminating Engineering, 46 (1951), n.2, 65
  • [26] Lulla A.B., Bennet C.A., Discomfort glare: Range effects, Journal of IES, 10 (1981), n.2, 74
  • [27] Kent M., Fotios S., Altomonte S., An experimental study on the effect of visual tasks on discomfort due to peripheral glare, LEUKOS, 2018 , 1-12, DOI: 10.1080/15502724.2018.1489282
  • [28] Kim W., Kim J.T.A., Position Index Formula for Evaluation of Glare Source in the Visual Field , Indoor and Built Environment. 20 (2011), issue 1, 47-53
  • [29] Luckiesh M., Guth S.K., Discomfort glare and angular distance of glare source, Illuminating Engineering, 41 (1946), n.6, 485
  • [30] Wonwoo K., Yasuko K., MELO O., Position Index for a Glare Source in the Whole Visual Field. Journal of the Illuminating Engineering Institute of Japan, 88 (2004), n.07
  • [31] Ostberg O., Stone P.T., Benson R.A., Free magnitude estimation of discomfort glare and working task difficulty. Goteborg Psychological Reports. 15 (1975), 5, 1.
  • [32] Sivak M., Flannagan M., Discomfort glare is task dependent. Proc CIE 22 nd Session, Melbourne 1991.
  • [33] Ma S., Yang Y., Ronnier M., Liu L.X., Assessing and modeling discomfort glare for raw white LEDs with different patterns. Leukos, 13 (2017), issue 2, 59-70
  • [34] Yang Y., Ma S.N., luo M.R., Liu X.Y., Discomfort glare caused by non-uniform white led matrices . Proceedings of 28th CIE Session 2015, Manchester, UK , 27 June – 4 July, 2015, 393-399
  • [35] Yang, M Ronnier Luo, Ma S.N., Liu X.Y., Assessing glare. Part 1: Comparing uniform and non-uniform LED luminaires, Lighting Research & Technology, 49 (2017), n.2, 195-210
  • [36] Yang, M Ronnier Luo, Ma S-N: Assessing glare. Part 2: Modifying Unified Glare rating for uniform and non-uniform LED luminaires LED luminaires, Lighting Research & Technology, 49 (2017), n.6, 727–742
  • [37] Donners MAH, Vissenberg MCJM, Geedrinck LM, van den Broek-Cools JHF, Buddermeijer –Lock A. A psychophysical model of discomfort glare in both outdoor and indoor applications. Proceedings of 28th CIE Session 2015, Manchester, UK , 27 June – 4 July, 2015, 1602-1610
  • [38] Schier GH, Hanselaer P, Bracke P, Deconinck G, Ryckaert Calculation of the unified glare rating based on luminance maps for uniform and non-uniform light sources. Building and Environment, 84 (2015), 60-67
  • [39] Schier GH, Hanselaer P, Van de Perre L, Ryckaert WR, Effectof luminance contrast on the perception of discomfort, Proceedings of 28th CIE Session 2015, Manchester, UK, 27 June – 4 July, 2015, 1870-1876
  • [40] Nakamura, Y., Takahashi, R., Sasabe, K.: Prediction of Discomfort Glare of a Non-Uniform Light Source by Use of Its Luminance Image. Proceedings of 28th CIE Session. Manchester 2015. pp. 400- 408
  • [41] Funke C, Schierz Ch. Extension of the unified glare rating formula for non-uniform led luminaires. Proceedings of 28th CIE Session 2015, Manchester, UK, 27 June – 4 July, 2015, 1471-1480
  • [42] Eble-Hankins M.L. Subjective impression of discomfort glare from sources of non-uniform luminance. Architectural Engineering - Dissertations and Student Research. Paper 1., 2008, University of Nebraska –Lincoln
  • [43] Eble-Hankins M.L., Waters C.E., Subjective impressions of discomfort glare from sources of non-uniform luminance, Leukos, 6 (2009), issue 1, 51–77
  • [44] Tashiro T., Kawanobe S., Kimura-Minoda T., Discomfort glare for white LED light sources with different spatial arrangements, Lighting Research and Technology, 47 (2015), Issue 3, 316-337
  • [45] Manabe H., The assessment of discomfort glare in practical lighting installations. Otemon Economic Studies. 1976, 9. Otemon Gakuin University, Osaka, Japan
  • [46] Stone P.T., Harker S.D.P., Individual and group differences in discomfort glare responses. Lighting Research and Technology 5 (1973), issue 1, 41-49
  • [47] Boyce P.R., Crisp V.H.C., Simons R.H., Rowlands E., Discomfort glare sensation and prediction. Proc CIE 19th Session, Kyoto 1979, 260
  • [48] Akashi Y., Muramatsu R., Kanaya S., Unified Glare Rating (UGR) and subjective appraisal of discomfort glare. Lighting Research and Technology, 28 (1996), Issue 4, 199-206
  • [49] Boyce P.R., Hunter C.M., Inclan C., Overhead glare and visual discomfort. Journal of IES, winter 2003, 73-88
  • [50] Sawicki D. Wolska A. Discomfort glare prediction by different methods. Lighting Research & Technology, 47 (2015), issue 6, 658-671
  • [51] Geerdinck L.M., Glare perception in terms of acceptance and comfort [graduation report]. Eindhoven University of Technology 2012
  • [52] Geerdinck L.M., Van Gheluwe J.R., Vissenberg M.C.J.M., Discomfort glare perception of non-uniform light sources in an office setting, Journal of Environmental Psychology. 39 (2014), 5-13
  • [53] Cai H., Chung T., Evaluating discomfort glare from non-uniform electric light sources. Lighting Research & Technology, 45 (2013), issue 3, 267-294
  • [54] Lou D., Deng S., Bian J., Van der Burgt P.J.M., Evaluation of Glare from Non-Uniform Indoor Luminaires. Proceedings of 28th CIE Session. Manchester 2015. 1860-1869
  • [55] Iacomussi P., Radis M., Rossi G., Rossi L., Visual Comfort with LED Lighting. Energy Procedia, 78 (2015), 729-734
  • [56] Melo O., An Assessment on the Limitations of the Unified Glare Rating (UGR) System. Comparison between Eastern and Western Subjects. Kyushu University - Graduate School of Human-Environment Studies, Universidade de Kyushu, Japão.,25.03.2002, 133-136
  • [57] Wolska A., Sawicki D. Evaluation of discomfort glare in the 50+ elderly: experimental study International Journal of Occupational Medicine and Environmental Health, 27 (2014), n.3, 444-459
  • [58] Bargary G., Jia Y., Barbur J.L., Mechanisms for discomfort glare in central vision. Investigative Ophthalmology & Visual Science, 56 (2015), n.1, 464-471
  • [59] CIE. Research Roadmap for Healthful Interior Lighting. International Commission on Illumination (CIE), ED/TR TC 346, 2016
  • [60] Akashi Y., Asano S., Kakuta Y. Visual Mechanisms of Discomfort Glare Sensation Caused by LEDs. Proc. of the CIE Centenary Conference Towards a New Century of Light, 15-16 April 2013, Paris, France, 327-330
  • [61] Cai H., Chung T., Evaluating discomfort glare from non-uniform electric light sources. Lighting Research & Technology, 45 (2013), issue 3, 267-294
  • [62] Sendrup P., Generalization of the unified glare rating method: a proposal and laboratory test. Lighting Research & Technology. 33 (2001), issue 4, 243-257
  • [63] Berman S.M., Bullimore M.A., Bailey I.L., Jacobs R.J. The Influence of Spectral Composition on Discomfort Glare for Large-Size Sources. Journal of the Illuminating Engineering Society, 25 (1996), n.1
  • [64] Bullough J.D., Brons J.A., Qi R., Rea M.S.,. Predicting discomfort glare from outdoor lighting installations. Lighting Research & Technology, 40 (2008), 225–242
  • [65] Sweater-Hickcox K.,Narendran N., Bullough J.D., Freyssinier J.P. Effect of different coloured luminous surrounds on LED discomfort glare perception. Lighting Research & Technology. 45 (2013), issue 4, 464-475
  • [66] Nonne J., Renoux D., Rossi L. Metrology for solid-state lighting quality. Proc. of The 16th International Congress of Metrology. October 7-10th 2013, Paris, France. 14004, 1-8
  • [67] Jiang C-J., Sun C-C., Chen Y-C. Yang T-H., Chang N., The correlation of veiling luminance and unified glare rating with a transfer function. Lighting Research & Technology. 46 (2014), issue 5, 587–592
  • [68] Rea M.S., Mou X., Bullough J.D. Scene brightness of illuminated interiors. Lighting Research & Technology. 48 (2016) issue 7, 823-831
  • [69] Kim J.T., Shin J.Y., YUN G.Y. Prediction of discomfort glare from windows: Influence of the subjective evaluation of window views. Proc. of The 5th International Symposium on Sustainable Healthy Buildings (SHB2011), Seoul, Korea. 10 February 2011. 283-289
  • [70] Karlsen L., Heiselberg P., Bryn I., Johra H. Verification of simple illuminance based measures for indication of discomfort glare from windows. Building and environment. 92 (2015), 615-626
  • [71] Kim W., Koga Y., Effect of local background luminance on discomfort glare. Building and Environment, 38 (2004), 1435-1442
  • [72] Kim W., Kim J.T., Effect of Background Luminance on Discomfort Glare in Relation to the Glare Source Size. Indoor and Built Environment, 19 (2010), n.1, 175-183
  • [73] Kim W., Han H., Kim J.T. The position index of a glare source at the borderline between comfort and discomfort (BCD) in the whole visual field. Building and Environment, 44 (2009), 1017-1023
  • [74] Tyukhova Y.I., Discomfort glare from small, high luminance light sources in outdoor nighttime environments (PhD thesis). 2015, University of Nebraska – Lincoln, USA
  • [75] Altomonte S., Kent M.G., Tregenza P.R., Wilson R. Visual task difficulty and temporal influences in glare response. Building and Environment. 95 (2016), 209-226
  • [76] Kent M.G., Altomonte S., Tregenza P.R., Wilson R., Discomfort glare and time of day. Lighting Research & Technology. 47 (2015), issue 6, 641-657
  • [77] Tuaycharoen N., Tregenza P.R. Discomfort glare from interesting images. Lighting Research & Technology. 37 (2005), n.4, 329-341
  • [78] Littlefield R. Theory of the “No-Parallax” Point in Panorama Photography. Version 1.0, February 6, 2006. Availavle from http://www.janrik.net/PanoPostings/NoParallaxPoint/TheoryOfT heNoParallaxPoint.pdf (last accessed 09.11.2018)
  • [79] Entrance Pupil Database. https://wiki.panotools.org/Entrance_Pupil_Database (last accessed 09.11.2018)
  • [80] Finding The No Parallax Point. http://www.reallyrightstuff.com/finding-the-no-parallax-point (last accessed 09.11.2018)
  • [81] Reinhard E., Ward G., Pattanaik S., Debevec P., High Dynamic Range Imaging. Morgan Kaufmann 2006
  • [82] LMK Mobile Advanced. Documentation and Instruction Manual of the TechnoTeam’s LMK Photometer System. Available also from http://www.technoteam.de/ (last accessed 15.12.2017)
  • [83] Camera Sensor Ratings by DxO Mark. http://www.dxomark.com/index.php/Cameras/Camera-SensorRatings/%28metrics%29/ (last accessed 23.01.2017)
  • [84] Canon EOS 550D Instruction Manual. Retrieved 29 October 2013, from http://www.canoneurope.com/support/consumer_products/products/cameras/digi tal_slr/eos_550d.aspx?type=manuals&language=EN.
  • [85] Sawicki D., Wolska A., (2013). Algorithm of HDR image preparation for discomfort glare assessment. Przeglad Elektrotechniczny, 89 (2013), n.2a, 87-90
  • [86] Wolf S. Entwicklung und Aufbau eines LeuchtdichteAnalysators zur Messung von Blendungskennzahlen. PhD Thesis. Technische Universität Ilmenau 2004.
  • [87] Porsch T., Funke C., Schmidt F., Schierz Ch., Measurement of the Unified Glare Rating (UGR) based on using ILMD. Proc. of the 28th CIE SESSION, Manchester, UK, June 28 - July 4, 2015. 536-542
Uwagi
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2019).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-21731f75-46be-43dc-b4a3-73d919556587
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.