Low voltage PV array model verification on computer aided test setup

Autorzy
Treść / Zawartość
Identyfikatory
Warianty tytułu
Konferencja
Computer Applications in Electrical Engineering (20-21.04.2015 ; Poznań, Polska)
Języki publikacji
EN
Abstrakty
EN
Low voltage photovoltaic (PV) array delivers electric power to the renewable energy systems which utilize step-up DC-DC converters. The performance of PV array is strictly dependent on environmental conditions such as solar radiation and ambient temperature. In this paper presented is MATLAB model of low voltage 3.2 kWp PV array composed of ten PV panels connected in parallel. The model itself is based on photodiode model and is supported by datasheet parameters of examined PV panels. Presented P-V curves show an influence of solar radiation and temperature on electric power produced by the array. The model simulation results were verified on computer aided laboratory test setup built upon LabVIEW environment. The test setup comprised PV array connected to 6 kW electronic DC load which was controlled by LabVIEW application. Since test conditions should be steady during test time each measurement of real PV array full P-V curve has to be done as quick as possible. This can be assured by computer aided measurement approach where time consumming tests can be easily automated and shortened. This paper presents PV array model, describes test setup and discusses laboratory test results.
Słowa kluczowe
Rocznik
Tom
Strony
183--189
Opis fizyczny
Bibliogr. 5 poz., rys., tab.
Twórcy
autor
  • Bialystok University of Technology
Bibliografia
  • [1] Luque A., Hegedus. S. “Handbook of Photovoltaic Science and Engineering” Second Editin, A John Willey & Sons, Ltd (2011).
  • [2] Kyocera KD P Series family specification rev. 421212, Kyocera Solar, Inc.
  • [3] Sera D., Teodorescu R., Rodrigues P. „PV panel model based on datasheet values”, IEEE International Symposium on Industrial Electronics, (2007).
  • [4] Jain S., Agarval V. „Comparison of the performance of maximum power point tracking schemes applied to single-stage grid-connected photovoltaic systems”, IET Electrical Power Application, 1, (5), pp. 753–762 (2007).
  • [5] Zentro-Elektrik GmbH KG, Electronic DC Load EL3000, EL4500, EL6000 series datasheet.