Experimental study of water tank under impulsive loading

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The performance of stainless steel water tank subjected to impulsive loading was experimentally studied in this paper. The gas gun was utilized to activate the projectile with high impact velocity. The activated projectile then impinged the impact transfer plate which pressed the airbag behind it. The inflated airbag between the impact transfer plate and water tank was adopted to transfer the impulsive loading from impact transfer plate to the water tank. The ultra-thin pressure sensors were placed between the airbag and water tank to record the pressure imposed onto the water tank and the potentiometers were attached at the back of water tank to record the displacement histories. The water tanks with two different front and rear plate thicknesses were investigated. In addition, the same water tank with and without filled water was compared to study the water effects on the response of water tank under impulsive loading. Besides the experimental studies, the FE method was adopted to reproduce the experiment and improve the current test method. Finally, the experimentally verified FE models were further used to study the water effects in reducing the deformation of water tank under blast loading.
Rocznik
Strony
986--996
Opis fizyczny
Bibliogr. 26 poz., rys., tab., wykr.
Twórcy
autor
  • Department of Civil and Environmental Engineering, National University of Singapore, Singapore
autor
  • Department of Civil and Environmental Engineering, National University of Singapore, Singapore
Bibliografia
  • [1] M. Zheng, S.C. Lee, Y. Wang, J.Y.R. Liew, Heat transfer analysis of water storage façade system, in: Proceedings of 10th Pacific Structural Steel Conference, 2013.
  • [2] W.A. Keenan, P.C. Wager, Mitigation of confined explosion effects by placing water in proximity of explosions, in: Proceedings of the 25th DOD Explosives Safety Seminar, 1992.
  • [3] C.E. Joachim, C.V. Lunderman, Blast suppression with water- results of small-scale test program, in: Proceedings of the 15th International Symposium on the Military Aspects of Blast and Shock, 1997.
  • [4] P. Chabin, F. Pitiot, Blast wave mitigation by water, in: Proceedings of the 28th DOD Explosives Safety Seminar, 1998.
  • [5] L.H.J. Absil, J. Weerheijm, A. Bryntse, A. Carlberg, Water mitigation of explosion effects experimental parametric study, in: Proceedings of the 29th DOD Explosives Safety Seminar, 2000.
  • [6] Y.S. Shin, M. Lee, K.Y. Lam, K.S. Yeo, Modelling mitigation effects of watershield on shock waves, Shock and Vibration 5 (1998) 225–234.
  • [7] W.K. Chong, K.Y. Lam, K.S. Yeo, G.R. Liu, O.Y. Chong, A comparison of simulation's results with experiment on water mitigation of an explosion, Shock and Vibration 6 (1999) 73–80.
  • [8] M. Cheng, K.C. Huang, O.Y. Chong, Numerical study of water mitigation effects on blast wave, Shock Waves 14 (3) (2005) 217–223.
  • [9] J.Y.R. Liew, T.Y. Wang, Novel steel-concrete-steel sandwich composite plates subjected to impact and blast load, Advances in Structural Engineering 4 (4) (2011) 673–686.
  • [10] S. Lan, T.S. Lok, L. Heng, Composite structural panels subjected to explosive loading, Construction and Building Materials 19 (2005) 387–395.
  • [11] S.K. Clubley, Non-linear long duration blast loading of cylindrical shell structures, Engineering Structures 59 (2014) 113–126.
  • [12] M. Foglar, M. Kovar, Conclusions from experimental testing of blast resistance of FRC and RC bridge decks, International Journal of Impact Engineering 59 (2013) 18–28.
  • [13] H. Arora, P.A. Hooper, J.P. Dear, Dynamic response of full-scale sandwich composite structures subject to air-blast loading, Composites Part A 42 (2011) 1651–1662.
  • [14] Z.S. Tabatabaei, J.S. Volz, J. Baird, B.P. Gliha, D.I. Keener, Experimental, numerical analyses of long carbon fiber reinforced concrete panels exposed to blast loading, International Journal of Impact Engineering 57 (2013) 70–80.
  • [15] D.N. Lacroix, G. Doudak, K. E.I-Domiaty, Retrofit options for light-frame wood stud walls subjected to blast loading, Journal of Structural Engineering 140 (4) (2014) 04013104.
  • [16] D. Whisler, H. Kim, A non-explosive test method for generating wide area dynamic blast-type pressure pulse loading on armored panels, International Journal of Impact Engineering 68 (2014) 28–40.
  • [17] N. Mostaghel, Blast load simulation system, US Patent US6536258 B1, 2003.
  • [18] W. Chen, H. Hao, Experimental investigations and numerical simulations of multi-arch double-layered panels under uniform impulsive loadings, International Journal of Impact Engineering 63 (2014) 140–157.
  • [19] A.M. Remennikov, J.Y.R. Liew, S.Y. Kong, K.W. Kang, Simulation of impulsive loading on columns using an inflatable airbag technique, in: Proceedings of the 8th International Conference on Shock & Impact Loads on Structures, 2009.
  • [20] J.O. Hollquist, LS-DYNA Keyword User's Manual, Livermore Software Technology Corporation, California, 2012.
  • [21] J.W. Boh, L.A. Louca, Y.S. Choo, Strain rate effects on the response of stainless steel corrugated firewalls subjected to hydrocarbon explosions, Journal of Constructional Steel Research 60 (2004) 1–29.
  • [22] N. Jones, Structural Impact, second ed., Cambridge University Press, New York, 2012.
  • [23] W.V. Titow, PVC Technology, fourth ed., Elsevier Applied Science, London, 1984.
  • [24] E.S. Hertel, The CTH Data Interface for Equation-of-State and Constitutive Model Parameters, Sandia Report SAND92-1297, 1992.
  • [25] U.S. Army Corps of Engineers, UFC 3-340-02: Structural to Resist the Effects of Accidental Explosions, Washington, 2008.
  • [26] ASCE, Blast Protection of Buildings, American Society of Civil Engineers, Virginia, 2011.