Increased operaton reliability through PD monitoring of stator winding

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Zwiększenie niezawodności poprzez monitorowanie wyładowań niezupełnych w uzwojeniu stojana
Języki publikacji
EN
Abstrakty
EN
In this article, the challenges in the application of continuous partial discharge (PD) monitoring of rotating machines are presented. A versatile partial discharge monitoring system is described that is applicable to different machines and can be connected to a vast range of sensors. The experience gathered from PD monitoring to assess the condition of turbo and hydro generator stator winding insulation is shown in the paper. The advantage of having a fully digital system, whose settings can be easily remotely adjusted is shown. The advanced features for noise and PD defects signal separation based on synchronous multi-channel techniques are also presented. Case studies are included, which indicate that critical defects can be detected early and their evolution can be monitored.
PL
W artykule opisano działanie uniwersalnego systemu ciągłego monitorowania wyładowań niezupełnych (wnz) w różnych typach maszyn wirujących. Przedstawiono doświadczenia wynikające z zastosowania tego systemu do oceny stanu izolacji wirnika turbo- i hydro- generatorów. Wskazano na zalety wynikające z posiadania systemu pomiaru cyfrowego wnz, którego zakresy pomiarowe mogą być łatwo dostosowywane do typu maszyny i poziomu sygnału zakłóceniowego. Wskazano na znaczenie automatycznego systemu do identyfikacji typu defektu w izolacji statora maszyny i na odróżnienie sygnałów wnz od sygnałów zakłóceniowych. Podano przykłady zastosowań, gdzie pokazano, że defekty krytyczne mogą być wcześnie wykryte, a ich ewolucja może być monitorowana w sposób ciągły.
Rocznik
Strony
95--101
Opis fizyczny
Bibliogr. 8 poz., rys.
Twórcy
  • OMICRON ENERGY SOLUTIONS GmbH, Germany Lorenzweg 5, 12099 Berlin, Germany
  • OMICRON ENERGY SOLUTIONS GmbH, Germany Lorenzweg 5, 12099 Berlin, Germany
autor
  • OMICRON ENERGY SOLUTIONS GmbH, Germany Lorenzweg 5, 12099 Berlin, Germany
autor
  • Katedra Elektrotechnologii i Diagnostki ZUT ul. Sikorskiego 37, 70-774 Szczecin, Poland
autor
  • OBRE Sp. z.o.o Lotnikow 9, 41-949 Piekary Śląskie, Poland
Bibliografia
  • [1]. IEC 60034-27-2, edition 1.0: “On-line partial discharge measurements on the stator Winding insulation of rotating electrical machines”, 2012.
  • [2]. IEEE guide to the measurement of partial discharges in rotating machinery, IEEE Standard 1434, 2000.
  • [3]. W. Koltunowicz, R. Plath: “Synchronous multichannel PD measurements”, IEEE Transactions on Dielectrics and Electrical Insulation, pp.1715-1723, vol. 15, no. 6, December 2008.
  • [4]. A. Claudi, S. Berlijn, P. Mohaupt: “Practical experiences and performance of monitoring systems”, CIGRÉ General Session, 2008.
  • [5]. G.C. Stone: “A perspective on online partial discharge monitoring for assessment of the conditio of rotating machine stator winding insulation”, IEEE Electr. Insul. Mag, vol.28, No.5, pp. 8-13. 2012
  • [6]. A. Cavallini, A. Contin, G.C. Montanari, and F. Puletti: “Advanced PD interference in on-field measurements”, I. Noise rejection, IEEE Trans. Dielectr. Electr. Insul. vol. 10, no. 2, 2003.
  • [7]. L.V. Badicu, W. Koltunowicz, M. Koch and A. Piccolo: “Return of experience from continuous PD monitoring of rotating machines”, paper OD1-06, in proceedings of the 18th International Symposium on High Voltage Engineering (ISH) in Seoul, 2013.
  • [8]. A. Piccolo, L.V. Badicu and W. Koltunowicz: “Increased operation reliability through continuous PD monitoring in the Java-Bali Region”, in proceedings of CEPSI Conference, Korea, 2014.