Comparison of coupling networks for EFT Pulses Injection

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Porównanie sieci sprzęgających do wstrzykiwania impulsów EFT
Języki publikacji
EN
Abstrakty
EN
The paper compares behaviour of different types of coupling/decoupling networks for immunity testing against electric fast transient (Burst) from the point of view of their pulse transfer as well as their directivity. Aim of the paper is to show the possibility of using also electromagnetic clamp instead of capacitive clamp, which is less robust, in case of in-situ testing or special testing. The influence of overvoltage protection elements for auxiliary equipment decoupling upon the resulting test severity level is evaluated.
PL
W artykule porównano właściwości różnych rodzajów sieci sprzęgających/odsprzęgających do badań odporności na szybkie elektryczne stany przejściowe (Burst) pod kątem przenoszenia impulsów oraz kierunkowości. Celem pracy jest wykazanie możliwości wykorzystania również cęgów elektromagnetycznych zamiast klamry pojemnościowej, która jest mniej wytrzymała w przypadku testów in-situ lub specjalnych. Oceniono wpływ elementów ograniczających przepięcia na odsprzęganie wyposażenia pomocniczego dla danego poziomu narażeń.
Rocznik
Strony
17--20
Opis fizyczny
Bibliogr. 11 poz., rys., wykr.
Twórcy
autor
  • Slovak University of Technology in Bratislava, Faculty of Electrical Engineering and Information Technology, Institute of Electrical Engineering, Ilkovičova 3, 812 19 Bratislava, Slovak Republic
autor
  • Slovak University of Technology in Bratislava, Faculty of Electrical Engineering and Information Technology, Institute of Electrical Engineering, Ilkovičova 3, 812 19 Bratislava, Slovak Republic
autor
  • Slovak University of Technology in Bratislava, Faculty of Electrical Engineering and Information Technology, Institute of Electrical Engineering, Ilkovičova 3, 812 19 Bratislava, Slovak Republic
Bibliografia
  • [1] M. I. Montrose and E. M. Nakauchi, “Testing for EMC Compliance: Approaches and Techniques,” Wiley-IEEE Press, ISBN: 978-0-471-43308-8, April 2004.
  • [2] P. Michalski and J. Chudorliński, “Increasing I2C bus immunity from industrial EMC disturbances,” Przeglad Elektrotechniczny, ISSN 0033-2097, No.11, 2015, No.2, pp 58-60.
  • [3] International Standard EN 61000-4-4:2012, Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test.
  • [4] International Standard EN 61000-4-6:2014, Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields.
  • [5] Lüthi Elektronik-Feinmechanik AG, RF current injection clamp type EM 101, manual.
  • [6] T. Williams, and S. Baker, “Uncertainties of Immunity Measurements,” Report of Project R2.2b1 of the National Measurement System Policy Unit’s Programme for Electrical Measurement. Schaffner EMC Systems Ltd. and Elmac Services, 2002, Internet source: <http://www.elmac.co.uk /r22b1/R22b1_mainrept.pdf>.
  • [7] S. Caniggia, E. Dudenhoeffer and F. Maradei, “Full-wave investigation of EFT injection clamp calibration setup,” 2010 IEEE Inter. Symposium on Electromagnetic Compatibility, Fort Lauderdale, FL, 25-30 July 2010, pp. 602-607.
  • [8] F. Musolino and F. Fiori, “Modeling the IEC 61000-4-4 EFT Injection Clamp,” IEEE Transactions on Electromagnetic Compatibility, Vol.50, No. 4, Nov. 2008, pp. 869-875.
  • [9] J. Hallon and M. Bittera, “Directivity of capacitive clamp for EFT pulses injection,” In Radioelektronika 2014 : Proceedings of 24th International Conference. Bratislava, Slovak Republic, April 15-16, 2014, pp. 225-228.
  • [10] N. Toscani, G. Spadacini, F. Grassi and S.A. Pignari, “Lumped and Distributed-Parameter Circuit Models of the Electromagnetic Clamp,” IEEE Transactions on Electromagnetic Compatibility, Vol.58, No. 4, Aug. 2016, pp.1007-1015.
  • [11] F. Grassi, S.A. Pignari, G. Spadacini, N. Toscani, and P. Pelissou, “Characterization of the IEC 61000-4-6 EM clamp for conducted-immunity testing,” In Aerospace EMC (Aerospace EMC), 2016 ESA Workshop on. IEEE, 2016.
Uwagi