An advanced approach to derive the constitutive law of UHPFRC

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
More than 200 specimens were tested in a comprehensive experimental campaign using ultra-high performance concrete with a mean compressive strength between 150 and 210 MPa and with different amounts of steel fibre reinforcement (0%, 1% and 2% by volume) from the first 2 days to 1.5 years after casting. From the large set of experimental tests related material parameters were derived. Based on compression tests with strain transducers and laser displacement transducers, the compression side of the constitutive law was derived, and based on the splitting tensile tests and flexural bending tests, the tensile side of the constitutive law was derived and the results are presented. For derivation of the tensile behaviour of ultrahigh performance fibre-reinforced concrete an advanced approach was applied by using a photogrammetric camera system with digital image correlation (DIC).
PL
Ponad 200 próbek zostało zbadanych w kompleksowej serii badań betonów bardzo wysokowartościowych o średnich wytrzymałościach na ściskanie od 150 do 210 MPa i przy zróżnicowanej ilości zbrojenia rozproszonego z włókien stalowych (0%, 1% i 2% objętości). Próbki badano w wieku od 2 dni do 1.5 roku po ułożeniu betonu. W poszczególnych seriach zbadano parametry materiałowe. W próbach ściskania, przy użyciu tensometrów i laserowych czujników przemieszczeń wyznaczono wartości ściskań do wykorzystania w równaniach konstytutywnych, a na podstawie prób rozciągania (w próbie rozłupywania przy ściskaniu wzdłuż pobocznicy) i wytrzymałości na zginanie wyznaczono wartości rozciągań do równań konstytutywnych. Do wyznaczenia wytrzymałości na rozciąganie betonu bardzo wysokowartościowego zbrojonego włóknami stalowymi zastosowano metodę fotogrametryczną z cyfrową korelacją obrazu (DIC).
Rocznik
Strony
89--96
Opis fizyczny
Bibliogr 8 poz.
Twórcy
autor
  • Faculty of Civil Engineering & Architecture, Carinthia University of Applied Sciences, Spittal an der Drau, Austria
autor
  • Faculty of Civil Engineering & Architecture, Carinthia University of Applied Sciences, Spittal an der Drau, Austria
Bibliografia
  • [1] Austrian Standards Institute. (2012). Testing hardened concrete, Part 1 - Part 7 (ÖNORM EN 12390). Vienna: Austrian Standards Institute.
  • [2] Austrian Standards Institute. (2010). Test methods for concrete - National application of testing standards for concrete and its source materials (ONR 23303). Vienna: Austrian Standards Institute.
  • [3] Skarżyński, Ł., Kozicki, J., & Tejchman, J. (2013). Application of DIC Technique to Concrete - Study on Objectivity of Measured Surface Displacements. Experimental Mechanics, 53(9), 1545-1559.
  • [4] Salamak, M., Owerko, T., & Łaziński, P. (2016). Displacements of cable-stayed bridge measured with the use of traditional and modern techniques. Architecture Civil Engineering Environment, 9(4), 89-97.
  • [5] Mészöly, T., & Randl, N. (2017). Derivation of constitutive law for UHPFRC using DIC system. In F. Toutlemonde, & J. Resplendino (Eds.), UHPFRC 2017 - Designing and Building with UHPFRC: New large-scale implementations, recent technical advances, experience and standards. RILEM Proceedings, PRO 106. (I, 221-230). Paris: RILEM.
  • [6] Deutscher Beton- und Bautechnik-Verein. (2001). DBV-Merkblatt Stahlfaserbeton (Steel fibre concrete:
  • [DBV-guide to good practice]).
  • [7] DAfStb. (2012). DAfStb-Richtlinie Stahlfaserbeton - Teil 2 (DAfStb Guideline Steel Fibre Reinforced Concrete - Part 2). Berlin: Beuth Verlag.
  • [8] AFGC. (2013). Ultra High Performance Fibre- Reinforced Concretes - Recommendation. Revised ed. Paris: Association Française de Génie Civil.