PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

I-SCAN Method for the Assessment of Pressure Exerted by Textile Products

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Metoda I-SCAN w ocenie nacisku wywieranego przez wyroby włókiennicze
Języki publikacji
EN
Abstrakty
EN
The capabilities of the I-SCAN (TekScan) system for pressure measurements were tested in in vivo and in vitro condition using hosiery articles at a pressure of 18-21mmHg, as declared by the manufacturers. For two types of knee-length socks with the same structure and slight difference in composition (polyamide/elastomer 78/22% and 64/36%) the pressure was measured on the ankle and calf in four positions (1-front, 2-inner side, 3-back, 4-outer side). The highest pressure values were found for the 1-front position and the lowest for the 2-inner side position. It was shown that there is a correlation between the in vivo and in vitro tests. The I-SCAN method allows to take measurements in various place and to create maps of the pressure distribution.
PL
Nacisk wyrobów włókienniczych może powodować niepożądany wpływ na użytkownika lub działać profilaktycznie. W obu przypadkach ocena nacisku wymaga odpowiednich metod dostosowanych do przeznaczenia wyrobu. Badano możliwości systemu I-SCAN (TekScan) w warunkach in vivo i in vitro, na przykładzie wyrobów pończoszniczych należących do pierwszej klasy nacisku 18-21mmHg. W przeciwieństwie do powszechnie stosowanych metod, metoda I-SCAN bazująca na elastycznych matach pomiarowych umożliwia pomiar w dowolnym miejscu i tworzenie map nacisku. Dla dwóch rodzajów podkolanówek o zbliżonym składzie (poliamid/elastomer 78/22% i poliamid/elastomer 64/36%), i takiej samej strukturze zmierzono nacisk na wysokości kostki i łydki w czterech pozycjach (1–przód, 2-strona wewnętrzna, 3–tył, 4–strona zewnętrzna). Największy nacisk na kostce i łydce występował w pozycji 1-przód, a najmniejszy w pozycji 2-strona wewnętrzna. Wykazano, że dla metody I-SCAN istnieje korelacja między badaniami in vivo i in vitro.
Rocznik
Strony
121--127
Opis fizyczny
Bibliogr. 28 poz., rys., tab.
Twórcy
autor
  • Textile Research Institute, Łódź, Poland
  • Textile Research Institute, Łódź, Poland
  • Textile Research Institute, Łódź, Poland
  • Textile Research Institute, Łódź, Poland
Bibliografia
  • 1. Partsch H, Partsch B and Braun W. Interface pressure and stiffness of ready made compression stockings: Comparison of in vivo and in vitro measurements. J Vasc Surg 2006; 44: 809-814.
  • 2. Partsch H, Winiger J and Lun B. Compression stockings reduce occupational leg swelling. Dermatol Surg 2004; 30: 737-743.
  • 3. Referentiel technique prescrit pour les ortheses elastiques de contention des membres, ASQUAL, 1999.
  • 4. RAL-GZ 387:2008. Medical Compression Hosiery. Quality Assurance.
  • 5. BS 6612:1985. Specification for graduated compression hosiery.
  • 6. PN-ENV 12718:2002. Medical compression hosiery.
  • 7. DIN 58133: 2008. Medical compression hosiery.
  • 8. European Committee for Standardization (CEN). No-Active Medical Devices. Working Group 2 ENV 12718: European Prestandard ,,Medical Compression Hosiery”, CEN TC 205; CEN: Brussels, 2001.
  • 9. Clark M and Krimmel G. Lymphoedema and the construction and classification of compression hosiery. In Lymphoedema Framework. Template for Practice: Compression hosiery in lymphoedema. MEP Ltd, London 2006, pp 2-4.
  • 10. Ališauskienė D, Mikučionienė D and Milašiūtė L. Influence of inlay-yarn properties and insertion density on the compression properties of knitted orthopaedic supports. Fibres and Textiles in Eastern Europe 2013; 21, 6(102): 74-78.
  • 11. Liu R, Kwok YL, Li Y and Lao TT. Fabric Mechanical-surface properties of compression hosiery and their effects on skin pressure magnitudes when worn. Fibres and Textiles in Eastern Europe 2010; 18, 2(79): 91-97.
  • 12. Mirjalili SA, Rafeeyan M and Soltanzadeh Z. The analytical study of garment pressure on the human body using finite elements. Fibres and Textiles in Eastern Europe 2008; 16, 3(68): 69-73.
  • 13. Senthilkumar M, Kumar LA and Anbuman N. Design and development of a pressure sensing device for analysing the pressure comfort of elastic garments. Fibres and Textiles in Eastern Europe 2012; 20, 1(90): 64-69.
  • 14. Kowalski K. Mielicka E and Kowalski TM. Modelling and designing compression garments with unit pressure measured for body circumferences of a variable curvature radius. Fibres and Textiles in Eastern Europe 2012; 20, 6A(95): 98-102.2
  • 15. Mirjalili SA, Rafeeyan M and Soltanzadeh Z. The Analytical Study of Garment Pressure on the Human Body Using Finite Elements. Fibres and Textiles in Eastern Europe 2008; 3(68): 69-73.
  • 16. Liu R, Kwok YL, Li Y, Lao TT and Zhang X. Effects of material properties and fabric structure characteristics of graduated compression stockings (GCS) on the skin pressure distributions. Fibers and Polymers 2005; 4: 322–333.
  • 17. Liu R, Kwok YL, Li Y, Lao TTH, Zhang X and Dai X.Q. Objective evaluation of skin pressure distribution of graduated elastic compression stockings. Dermatol Surg 2005; 31: 615-624.
  • 18. Suehiro K, Morikage N, Murakami M, Yamashita O and Hamano K. Interface pressures derived from oversized compression stockings. Ann Vasc Dis 2012; 5: 342-346.
  • 19. PN-EN 12127:2000. Textiles. Fabrics. Determination of mass per unit area using small samples.
  • 20. PN-EN ISO 5084:1999. Textiles. Determination of thickness of textiles and textile products.
  • 21. PN-EN 14704-1:2006. Determination of the elasticity of fabrics. Strip tests.
  • 22. PN-EN ISO 9237: 1998. Textiles. Determination of the permeability of fabrics to air.
  • 23. PN-EN 14971:2007. Textiles. Knitted fabrics. Determination of number of stitches per unit length and unit area.
  • 24. User Manual I-SCAN: Tekscan I-SCAN® & Speed I-SCAN®. TEKSCAN; 2010.
  • 25. DD ENV 12718: 2001. Medical compression hosiery.
  • 26. Veraart JC, Pronk G and Neumann HA. Pressure differences of elastic compression stockings at the ankle region. Dermatol Surg 1997; 23: 935-939.
  • 27. Stat Soft. Inc. Electronic Statistics Texbook. Tulsa, OK.: Statsoft. WEB, //www.statsoft.com/textbook/ 2010.
  • 28. Dai XQ, Liu R.,Li Y, Zhang M and Kwok YL. Numerical simulation of skin pressure distribution applied by graduated compression stocking. Studies in Computational Intelligence (SCI) 2007; 55: 301-309
Uwagi
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę (zadania 2017).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-191f3bab-71cc-466a-afbf-7c01f4432143
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.