Pilot Plant Studies on Nox Removal Via No Ozonation and Absorption

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Badania w skali pilotowej dotyczące efektywności usuwana NOx porzez utlenianie NO i absorpcję
Języki publikacji
EN
Abstrakty
EN
The results of experimental investigations on the removal of NOx from gases applying ozone as the oxidizing agent and the absorption of higher nitrogen oxides in the sodium hydroxide solutions are presented. The experiment was conducted using a pilot plant installation with the air flow rate 200 m3/h, being a prototype of a boiler flue gas duct and a FGD scrubber. It was shown that in the range of [NOref] = 50 ÷ 250 ppm the mechanism of NO ozonation depends on the molar ratio X = O3/NOref: for X ≤ 1.0 oxidation of NO to NO2 predominates and NO2 is poorly absorbed, for X >> 1.0 NO2 undergoes further oxidation to N2O5, which is efficiently absorbed in the scrubber. The stoichiometric molar ratio of complete conversion of NO into N2O5 is X = 1.5, in these studies to reach the effectiveness η ≥ 90% the molar ratio X was much higher (2.75).
PL
Przedstawiono wyniki badań doświadczalnych dotyczące usuwania NOx z gazów z zastosowaniem ozonu jako utleniacza i absorpcji wyższych tlenków azotu w roztworach wodorotlenku sodu. Badania prowadzono na strumieniu powietrza 200 m3/h w instalacji pilotowej będącej prototypem instalacji kotłowej odprowadzenia spalin i skrubera IOS. Wykazano, że w zakresie [NOref] =50÷250 ppm mechanizm ozonizacji NO zależy od stosunku molowego X = O3/NOref: dla X ≤ 1.0 przeważa utlenianie NO do NO2 a NO2 jest słabo absorbowany, dla X >> 1,0 NO2 ulega dalszemu utlenianiu do N2O5, który jest efektywnie absorbowany w skruberze. Stosunek molowy przy całkowitej konwersji NO do N2O5 wynosi X = 1.5, w przeprowadzonych badaniach, aby osiągnąć efektywność η ≥ 90% stosunek X był dużo większy (2,75).
Słowa kluczowe
Rocznik
Strony
93--106
Opis fizyczny
Bibliogr. 20 poz., rys., tab., wykr.
Twórcy
  • Wrocław University of Technology, Faculty of Mechanical and Power Engineering, Institute of Power Engineering and Fluid Mechanics Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland
autor
  • Wrocław University of Technology, Faculty of Mechanical and Power Engineering, Institute of Power Engineering and Fluid Mechanics Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland
autor
  • Wrocław University of Technology, Faculty of Mechanical and Power Engineering, Institute of Power Engineering and Fluid Mechanics Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland
Bibliografia
  • [1] Bertram, T.H., & Thornton, J.A. (2009).Towards a general parameterization of N2O5 reactivity on aqueous particles: the competing effects of particle liquid water, nitrate and chlorides. Atmospheric Chemistry and Physics. 9, 8351–8363.
  • [2] Chironna, R.J., & Altshuler, B.(1999). Chemical aspects of NOx scrubbing. Pollution Engineering, 4, 32–36.
  • [3] Directive 2001/80/EC of the European Parliament and of the Council. 2001.
  • [4] Directive 2010/75/EU of the European Parliament and of the Council. 2010.
  • [5] Dora, J., Gostomczyk, M.A., Jakubiak, M., Kordylewski, W., Mista, W., & Tkaczuk, M. (2009). Parametric studies of the effectiveness of oxidation of NO by ozone. Chemical and Process Engineering, 30, 621–634.
  • [6] Ellison, W. (2003). Chemical process design alternatives to gain simultaneous removal in scrubbers. Las Vegas: POWER-GEN International.
  • [7] Fu, Y., & Diwekar, U.M. (2004). Cost effective environmental control technology for utilities. Advances in Environmental Research, 8, 173–196.
  • [8] Głowiński, J., Biskupski, A., Słonka, T., & Tylus, W. (2009). Absorption of nitrogen oxides at the final stage of ammonium nitrite production. Chemical and Process Engineering, 30, 217–229.
  • [9] Jakubiak, M., & Kordylewski, W. (2010). Effectiveness of NOx removal from gas via preoxidation of NO with ozone and absorption in alkaline solutions. Chemical and Process Engineering, 31, 699–709.
  • [10] Joshi, J.B., Mahajani, V.V., & Juvekar, V.A. (1985). Absorption of NOx gases. Chemical Engineering Communications, 33, 1–92.
  • [11] Kryza, M., Błaś, M., Dore, A.J., & Sobik, M. (2010). Fine-Resolution Modeling of Concentration and Deposition of Nitrogen and Sulphur Compounds for Poland – Application of the FRAME Model. Archives of Environmental Protection, 36, 49–62.
  • [12] Krotla, K., Wala, T. & Brudziana, P. (2009). Porównanie nakładów inwestycyjnych i kosztów eksploatacji urządzeń typu SCR w zależności od stopnia redukcji NOx, IX Conference Research and Development In Power Engineering – RDPE, Warszawa, 8–11 December (2009).
  • [13] Nelo, S.K., Leskela, K.M., & Sohlo, J.J.K. (1997). Simultaneous Oxidation of Nitrogen Oxide and Sulfur Dioxide with Ozone and Hydrogen Peroxide. Chemical Engineering & Technology, 20, 40–42.
  • [14] Nist database: www.nist.gov, 2012.
  • [15] Omar, K. (2008). Evaluation of BOC’s Lotox process for the oxidation of elemental mercury in fl ue gas from a coal fired boiler. Wyoming: Western Research Institute Laramie.
  • [16] Prather, M.J., & Logan, J.A. (1994). Combustion’s impact on the global atmosphere. 25th Symposium (International) on Combustion, Pittsburgh, USA, 31 July – 5 August 1994, 1513–1527.
  • [17] Pronobis, M. (2002). Modernization of power plants boilers (in Polish). Warszawa: Wydawnictwo Naukowo-Techniczne.
  • [18] Skalska, K., Miller, J.S., & Ledakowicz, S. (2011). Kinetic model of NOx ozonation and its experimental verifi cation. Chemical Engineering Science, 66, 3386–3391.
  • [19] Thielmann, M., Scheibler, E., & Wiegand, K.W. (2005). Nitric Acid, Nitrous Acid, and Nitrogen Oxides. 177–255.Wenheim: Ullmann’s Encyclopedia of Industrial Chemistry, Wiley-Vch.
  • [20] Thomas D., & Vaderschuren, J. (1999). Analysis and prediction of the liquid phase composition for the absorption of the nitrogen oxides into aqueous solutions. Separation and Purification Technology, 18, 37–45.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-14c449f6-b0a8-445c-9a4b-b986d8f0c176
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.