PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Computer aided and 3D printing in pre-operative planning of orbital reconstruction surgery

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
This article describes the example of a computer aided and 3D print of a patient’s fractured orbital preoperational reconstruction surgery planning. On basis of a medical visualization a triangular model of the facial part of the skull with the fractured orbital has been developed. Using the haptic voxel modeling tools the model has been improved and next the model of the reconstructed orbital has been made. This model served to build a physical model. Using the physical model of the orbital the reconstruction mesh has been made which was then implanted into the patient’s skull. The entire surgery was completed with no complications and the patient regained proper sight.
Rocznik
Strony
20--30
Opis fizyczny
Bibliogr. 11 poz., rys.
Twórcy
autor
  • Silesian University of Technology, Gliwice, Poland
  • Silesian University of Technology, Gliwice, Poland
autor
  • Medical University of Warsaw, Poland
Bibliografia
  • [1] Bordegoni M., Cugini U. (2005). Haptic modeling in the conceptual phases of product design. VIRTUAL REALITY, 2005, 2-3(9), 192-202.
  • [2] Cierniak M. Computed tomography. Construction of CT. Reconstruction algorithms, Warsaw, Academic Publishing House EXIT, 2005.
  • [3] Geomagic®Claytools®, http://geomagic.com/en/products/claytools/overview. Accessed 3 March 2015.
  • [4] InVesalius, http://www.cti.gov.br/invesalius. Accessed 10 March 2015.
  • [5] Karbowski K., Urbanik A., Wyleżoł M. Image analysis and virtual modeling in designing of skull prosthesis, Mechanik, 2010, 7, 620-622.
  • [6] Materialise, http://biomedical.materialise.com/mimics. Accessed 3 March 2015.
  • [7] Muzalewska (Otrębska) M., Szczodry B., Samolczyk-Wanyura D. Pre-operative planning for mandibular resection and reconstruction using computer aided and generative technologies, Mechanik, 2014, 02, 1-7 (CD-ROM).
  • [8] Osirix, http://www.osirix-viewer.com. Accessed 16 March 2015.
  • [9] Wyleżoł M. Use of haptic methods in engineering modeling and analysis – examples, Mechanik, 2009, 11, 948.
  • [10] Wyleżoł M., Muzalewska M. Modeling methodology in biomedical engineering with use of reverse engineering, Mechanik, 2015, 2, K42 (CD-ROM).
  • [11] Wyleżoł M. Methods of skull implants modeling with use of CAx and haptic systems. I: Handbook of Research on Interactive Information Quality in Expanding Social Network Communications Cipolla-Ficarra F. V., IGI Global, 2015, 119-139, DOI:10.4018/978-1-4666-7377-9.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-145ecf86-4109-496f-bebe-29158e1e33f7
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.