An universal test station for multichannel integrated neural amplifiers based on LabVIEW environment

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Projekt uniwersalnego stanowiska do testów wielokanałowych scalonych wzmacniaczy sygnałów neurobiologicznych opartego o środowisko LabVIEW
Języki publikacji
EN
Abstrakty
EN
Modern technology allows for design of sophisticated measurement systems utilizing hundreds of independent recording channels. That imposes necessity of complex system functionality validation procedures development. The article describes an universal test system dedicated for tests of multichannel integrated circuits implemented in submicron technologies. Preliminary measurement results of a multichannel integrated circuit dedicated for advanced neurobiological experiments are also presented in the article.
PL
Współczesne technologie umożliwiają budowę systemów składających się z setek niezależnych torów pomiarowych o rozbudowanej funkcjonalności. Nakłada to konieczność przeprowadzenia szeregu testów weryfikujących ich działanie. Artykuł prezentuje projekt uniwersalnego systemu testującego opracowanego na potrzeby projektowanych, w technologiach submikronowych, wielokanałowych układów scalonych. W artykule przedstawiono również wyniki wstępnych pomiarów układu przeznaczonego do złożonych eksperymentów neurobiologicznych.
Rocznik
Strony
115--118
Opis fizyczny
Bibliogr. 7 poz., rys., wykr.
Twórcy
autor
  • AGH University of Science and Technology, Department of Measurement and Electronics, al. Adama Mickiewicza 30, 30-059 Kraków
autor
  • AGH University of Science and Technology, Department of Measurement and Electronics, al. Adama Mickiewicza 30, 30-059 Kraków
Bibliografia
  • [1] Bagheri A., Tariqus Salam M., Perez Velazquez J. L., Genov R., 56-Channel Direct-Coupled Chopper-Stabilized EEG Monitoring ASIC with Digitally-Assisted Offset Correction at the Folding Nodes, IEEE Biomedical Circuits and Systems Conference, (2014), 659-662
  • [2] Kassiri H., Bagheri A., Soltani N., Abdelhalim K., Mazhab Jafari H., Tariqus Salam M., Perez Velazquez J. L., Genov R., Inductively-powered direct-coupled 64-channel chopperstabilized epilepsy-responsive neurostimulator with digital offset cancellation and tri-band radio, European Solid State Circuits Conference, (2014), 95-98
  • [3] Rodríguez-Pérez A., Ruiz-Amaya J., Delgado-Restituto M., Sawan M., Rodríguez-Vázquez Á., A Self-Calibration Circuit for a Neural Spike Recording Channel, IEEE Biomedical Circuits and Systems Conference, (2011), 464-467
  • [4] Cabrera-López J. J., Romero-Beltrán C. A., Auto-Adjustable Low-Signal Processing Technique Based On Programmable Mixed-Signal SoCs, IEEE 9th Ibero-American Congress on Sensors, (2014), 1-4
  • [5] Kmon P., Digitally assisted neural recording and spike detection multichannel integrated circuit designed in 180nnm CMOS technology, Microelectronics Journal, 45 (2014), n. 9, 1187-1193
  • [6] Żołądź M., Kmon P., Rauza J., Gryboś P., Blasiak T., Multichannel neural recording system based on family ASICs processed in submicron technology, Microelectronics Journal, 45 (2014), n. 9, 1226-1231
  • [7] Kmon P., Gryboś P., Żołądź M., Lisicka A., Fast and effective method of CMRR enhancement for multichannel integrated circuits dedicated to biomedical measurements, Electronics Letters, 51 (2015), n. 22, 1736-1738
Uwagi
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę.