Prestresssed concrete usage in church buildings construction in Poland

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Zastosowanie betonu sprężonego w projektach budynków kościołów w Polsce
Języki publikacji
EN
Abstrakty
EN
restressed concrete was used to raise building constructions in Poland at the beginning of 1950s. Firstly, large span post-tensioned roof girders were made in industry halls, warehouses, airport hangars ....and so on, and also they were used to construct large capacity liquid tanks and bridges. The new form of post-tensioning, which means unbonded tendons, was used in buildings after 2000. Lately, the first time in Poland, prestressing has been used in project of two churches. As a result of using the unbonded tendons attractive forms were received. The slender prestressed slab supported on the steel “sapling” was constructed in the first of them. A prestressed concrete circumferential ring allows to create a delicate structure of timber girders in the second church. In this paper, these solutions are presented in detail together with the obtained benefits and proper calculation results.
PL
Istniejący w projektowaniu kościołów trend dążący do tworzenia delikatnych i smukłych form wymusza poszukiwanie nowoczesnych form konstrukcyjnych. Wobec powyższego po raz pierwszy w Polsce zastosowano cięgna sprężające bez przyczepności w projektach dwóch kościołów. W pierwszym z nich zaprojektowano smukłą płytę antresoli dla chóru, wspartą na stalowych podporach. W drugim zastosowano sprężony wieniec obwodowy. W pracy przedstawiono przyjęte założenia, wyniki analizy statyczno-wytrzymałościowej oraz szczegóły przyjętych rozwiązań konstrukcyjnych.
Rocznik
Strony
185--195
Opis fizyczny
Bibliogr. 6 poz., il.
Twórcy
  • IMBS, Faculty of Civil Engineering, Cracow University of Technology
autor
  • TCE Structural Design & Consulting
Bibliografia
  • [1] Post-tensioned concrete floors. Design handbook, Technical Report No. 43, second edition, The Concrete Society, Cromwell Press, Wiltshire, UK, 2005.
  • [2] Schwab F.C., Chow P.Y., Kulka F., Prestressed ring beam saves time and money on domed convention hall, PCI Journal, September–October 1974, 98–106.
  • [3] Onysyk J., Prabucki P., Sadowski K., Biliszczuk J., Strengthening of the lower ring of the ribbed reinforced concrete dome of the Centennial Haill in Wrocław, The 7th Central European Congress on Concrete Engineering, Balatonfüred, Hungary, 2011.
  • [4] Onysyk J., Biliszczuk J., Prabucki P., Sadowski K., Strengthening of the lower ring of reinforced concrete dome of the Centennial Haill in Wrocław, Inżynieria i Budownictwo, Vol. LXVIII, No. 7, 2012, 361–365.
  • [5] EN 1992-1-1 Eurocode 2 Design of concrete structures – Part 1-1: General rules and rules for buildings, European Committee of Standardization, December 2004.