Tytuł artykułu
Treść / Zawartość
Pełne teksty:
Identyfikatory
Warianty tytułu
Języki publikacji
Abstrakty
This article investigates the impact of a high-voltage direct-current (HVDC) link and a wind turbine system (WTS) on the dynamics of a three-area thermal automatic generation control (AGC) system. A novel controller, the cascade of proportional-integral (PI) and tilt-integralderivative (TID) with filter coefficient (N) (PI-TIDN) controller is projected. The WTS units are subjected to various wind velocity scenarios, including fixed and random wind velocities. The controller parameters are concurrently enhanced using the hybrid crow search algorithm (HCSA). The system dynamics corresponding to the PI-TIDN controller are superior to those of PIDN and TIDN controllers. Additionally, studies with different wind velocities demonstrate that responses with fixed wind velocities are better than those with random wind velocities. Moreover, integrating WTS units with the thermal system improves dynamics compared to the thermal system alone. It is also apparent that the parallel AC-HVDC system enhances dynamics. Furthermore, sensitivity analysis exposes that the PI-TIDN controller values at nominal settings are vigorous and do not require retuning.
Czasopismo
Rocznik
Tom
Strony
755--776
Opis fizyczny
Bibliogr. 42 poz., rys., tab., wzory
Twórcy
autor
- Department of Electrical and Electronics Engineering, Aditya University, Surampalem, Andhra Pradesh, India
- Department of Electrical Engineering, Rajkiya Engineering College Sonbhadra, U.P., India
autor
- Department of Electrical/Electronics and Instrumentation Engineering, Institute of Chemical Technology, Indianoil Odisha Campus, Bhubaneswar 751013, India
- Ingenium Research Group, University of Castilla-La Mancha, Spain
Bibliografia
- [1] O.I. Elgerd: Electric Energy Systems Theory: An Introduction. New Delhi, Tata McGraw-Hill, 2007.
- [2] P. Kundur: Power System Stability and Control. New Delhi, Tata McGraw Hill, 1993.
- [3] O.I. Elgerd and C.E. Fosha: Optimum megawatt-frequency control of multi-area electric energy systems. IEEE Transactions on Power Apparatus and Systems, 89(4), (1970), 556-563. DOI: 10.1109/TPAS.1970.292602
- [4] H. Golpira, H. Bevrani and H. Golpira: Application of GA optimization for automatic generation control design in an interconnected power system. Energy Conversion and Management, 52(5), (2011) 2247-2255. DOI: 10.1016/j.enconman.2011.01.010
- [5] J. Nanda, A. Mangla and S. Suri: Some new findings on automatic generation control of an interconnected hydrothermal system with conventional controllers. IEEE Transactions on Energy Conversion, 21(1), (2006), 187-194. DOI: 10.1109/TEC.2005.853757
- [6] N.R. Babu, T. Chiranjeevi, A. Saha and S.K. Bhagat: Comparative analysis of various energy storage systems in a conventional LFC system considering RDSTS, PWTS and AHVDC models. Journal of Engineering Research, 1(4), (2023), 425-436. DOI: 10.1016/j.jer.2023.100123
- [7] M. Javad, Z. Kazem and T.H. Mehrdad: Applying fractional order PID to design TCSC-based damping controller in coordination with automatic generation control of interconnected multi-source power system. Engineering Science and Technology, an International Journal, 20(1), (2017), 1-17. DOI: 10.1016/j.jestch.2016.06.002
- [8] N.R. Babu, T. Chiranjeevi, A. Saha, S.K. Bhagat, U.K. Gupta and R.I. Vais: Crow search algorithm optimized cascade controller in a multi-area thermal wind integrated system and its real-time validation. Electrica, 23(3), (2023), 429-437. DOI: 10.5152/electr.2023.22137
- [9] N.R. Babu, T. Chiranjeevi, R. Devarapalli, L. Knypiński and P.G. Marquez: Real-time validation of an automatic generation control system considering HPA-ISE with crow search algorithm optimized cascade FOPDN-FOPIDN controller. Archives of Control Sciences, 33(2), 371-390. DOI: 10.24425/acs.2023.146280
- [10] E. Rakhshani, K. Rouzbehi, M.A. Elsaharty and P.R. Cortes: Heuristic optimization of supplementary controller for VSC-HVDC/AC interconnected grids considering PLL. Electric Power Components and Systems, 45(3), (2017), 288-301. DOI: 10.1080/15325008.2016.1232765
- [11] J. Zhu, J.M. Guerrero, W. Hung, C.D. Booth and G.P. Adam: Generic inertia emulation controller for multi-terminal voltage-source-converter high voltage direct current systems. IET Renewable Power Generation, 8(7), (2014), 740-748. DOI: 10.1049/iet-rpg.2014.0109
- [12] A. Prakash, S. Murali, R. Shankar and R. Bhushan: HVDC tie-link modeling for restructured AGC using a novel fractional order cascade controller. Electric Power Systems Research, 170 (2019), 244-258. DOI: 10.1016/j.epsr.2019.01.021
- [13] N.R. Babu, T. Chiranjeevi, R. Devarapalli and S.K. Bhagat: Optimal location of FACTs devices in LFC studies considering the application of RT-Lab studies and Emperor Penguin optimization algorithm. Journal of Engineering Research, 11(2), (2023). DOI: 10.1016/j.jer.2023.100060
- [14] O.D. Adeuyi, M. Cheah-Mane, J. Liang, N. Jenkins, Y. Wu, C. Li and X. Wu: Frequency support from modular multilevel converter based multi-terminal HVDC schemes. IEEE Power and Energy Society General Meeting, Denver, (2015), 1-5. DOI: 10.1109/PESGM.2015.7286086
- [15] N. Pathak, A. Verma, T.S. Bhatti and I. Nasiruddin: Modeling of HVDC tie links and their utilization in AGC/LFC operations of multi-area power systems. IEEE Transactions on Industrial Electronics, 66(3), (2019), 2185-2197. DOI: 10.1109/TIE.2018.2835387
- [16] N.R. Babu, S.K. Bhagat, L.C. Saikia and T. Chiranjeevi: Application of hybrid crow-search with particle swarm optimization algorithm in AGC studies of multi-area systems. Journal of Discrete Mathematical Sciences and Cryptography, 23(2), (2020), 429-439. DOI: 10.1080/09720529. 2020.1728896
- [17] L.C. Saikia, A. Chowdhury, N. Shakya, S. Shukla and P.K. Soni: AGC of a multi area gas-thermal system using firefly optimized IDF controller. Annual IEEE India Conference, Mumbai, India, (2013), 1-6. DOI: 10.1109/INDCON.2013.6725998
- [18] G. Sharma, Ibraheem, K.R. Niazi and R.C. Bansal: Adaptive fuzzy critic based control design for AGC of power system connected via AC/DC tie-lines. IET Generation, Transmission and Distribution, 11(2), (2016), 560-569. DOI: 10.1049/iet-gtd.2016.1164
- [19] G. Sharma, I. Nasiruddin and K.R. Niazi: Robust automatic generation control regulators for a two-area power system interconnected via AC/DC tie-lines considering new structures of matrix Q. IET Generation, Transmission and Distribution, 10(14), (2016), 3570-3579. DOI: 10.1049/iet-gtd.2016.0321
- [20] K. Jagatheesan, B. Anand, Sourav Samanta, N. Dey, A.S. Ashour and V.E. Balas: Design of a proportional-integral-derivative controller for an automatic generation control of multi-area power thermal systems using firefly algorithm. IEEE/CAA Journal of Automatica Sinica, 6(2), (2019), 503-515. DOI: 10.1109/JAS.2017.7510436
- [21] I. Pan and S. Das: Fractional order AGC for distributed energy resources using robust optimization. IEEE Transactions on Smart Grid, 7(5), (2016), 2175-2186. DOI: 10.1109/TSG.2015.2459766
- [22] P.N. Topno and S. Chanana: Tilt integral derivative control for two-area load frequency control problem. 2nd International Conference on Recent Advances in Engineering and Computational Sciences, Chandigarh, India, (2015), 1-6.
- [23] S.K. Bhagat, S. Behera, A. Saha, T. Bal, T. Chiranjeevi, R. Devarapalli and N.R. Babu: Bird swarm algorithm optimized TIDD controller for multi-area load frequency control application. SN Computer Science, 4 (2023), 138. DOI: 10.1007/s42979-022-01556-5
- [24] N.R. Babu, S.K. Bhagat, T. Chiranjeevi, M. Pushkarna, A. Saha, H. Kotb, K.M. Abo-Ras, F. Alsaif, S. Alsulamy, Y.Y. Ghadi and D.T. Hermann: Frequency control of a realistic Dish Stirling Solar Thermal System and accurate HVDC models using a cascaded FO-PI-IDDN based crow-search algorithm. International Journal of Energy Research, (2023), 1-18. DOI: 10.1155/2023/9976375
- [25] A. Saha, P. Dash, N.R. Babu, T. Chiranjeevi, B. Venkateswararao and Ł. Knypiński: Impact of spotted hyena optimized cascade controller in load frequency control of wave-solar-double compensated capacitive energy storage based interconnected power system. Energies, 15(19), (2022). DOI: 10.3390/en15196959
- [26] A. Saha, P. Dash, N.R. Babu, T. Chiranjeevi, M. Dhananjaya and Ł. Knypiński: Dynamic stability evaluation of an integrated biodiesel-geothermal power plant-based power system with spotted hyena optimized cascade controller. Sustainability, 14(22), (2022). DOI: 10.3390/su1422 14842
- [27] A. Nocoń, S. Paszek and P. Pruski: Multi-criteria optimization of the parameters of PSS3B system stabilizers operating in an extended power system with the use of a genetic algorithm. Archives of Control Sciences, 32(2), (2022), 233-255. DOI: 10.24425/acs.2022.141711
- [28] T. Chiranjeevi and U.K. Gupta: Ideal parameter distribution in renewable integrated rapid charging electric vehicle station. Energy Sources, Part A: Recovery, Utilization, and Environmental Effects, 45(1), (2023), 888-904. DOI: 10.1080/15567036.2023.2174614
- [29] M. Ahsan, D. Bismor and M.A. Manzoor: ARL-wavelet-BPF optimization using PSO algorithm for bearing fault diagnosis. Archives of Control Sciences, 33(3), (2023), 589-606. DOI: 10.24425/acs.2023.146961
- [30] R.I. Vais, K. Sahay, T. Chiranjeevi, R. Devarapalli and Ł. Knypiński: Parameter extraction of solar photovoltaic modules using a novel bio-inspired swarm intelligence optimisation algorithm, Sustainability, 15, 8407. DOI: 10.3390/su15108407
- [31] A. Sahan and L.C. Saikia: Utilization of ultra-capacitor in load frequency control under restructured STPP-thermal power systems using WOA optimized PIDN-FOPD controller. IET Generation, Transmission and Distribution, 11(13), (2017), 3318-3331. DOI: 10.1049/ietgtd.2017.0083
- [32] W. Tasnin and L.C. Saikia: Maiden application of an sine-cosine algorithm optimised FO cascade controller in automatic generation control of multi-area thermal system incorporating dish-Stirling solar and geothermal power plants. IET Renewable Power Generation, 12(5), (2018), 585-597. DOI: 10.1049/iet-rpg.2017.0063
- [33] M. Raju, L.C. Saikia, N. Sinha and D. Saha: Application of ant-lion optimizer technique in restructured automatic generation control of two-area hydro-thermal system considering governor dead band. Conference on Innovations in Power and Advanced Computing Technologies, Vellore, India, (2017). DOI: 10.1109/IPACT.2017.8245099
- [34] A. Rahman, L.C. Saikia and N. Sinha: Load frequency control of a hydro-thermal system under deregulated environment using biogeography-based optimized three-degree-of freedom integral derivative controller. IET Generation, Transmission and Distribution, 9(15), (2015), 2284-2293. DOI: 10.1049/iet-gtd.2015.0317
- [35] J. Pierezan and L.D.S. Coelho: Coyote optimization algorithm: A new metaheuristic for global optimization problems. IEEE Congress on Evolutionary Computation, Rio de Janeiro, (2018). DOI: 10.1109/CEC.2018. 8477769
- [36] J. Kennedy and R. Eberhart: Particle swarm optimization. Proceedings of ICNN’95 - International Conference on Neural Networks, Perth, Australia, 4 (1995), 1942-1948. DOI: 10.1109/ICNN.1995.488968
- [37] P. Dash, L.C. Saikia and N. Sinha: Comparison of performances of several FACTS devices using Cuckoo search algorithm optimized 2DOF controllers in multi-area AGC. International Journal of Electrical Power and Energy Systems, 65 (2015), 316-324. DOI: 10.1016/j.ijepes.2014.10.015
- [38] A. Askarzadeh: A novel metaheuristic method for solving constrained engineering optimization problems: Crow search algorithm. Journal of Computers and Structures, 169 (2016), 1-12. DOI: 10.1016/j.compstruc. 2016.03.001
- [39] S.K. Bhagat, N.R. Babu, L.C. Saikia, T. Chiranjeevi, R. Devarapalli and P.G. Marquez: A review on various secondary controllers and optimization techniques in automatic generation control. Archives of Computational Methods in Engineering, 30 (2023), 3081-3111. DOI: 10.1007/s11831-023-09895-z
- [40] Ramjug-Ballgobin and C. Ramlukon: A hybrid metaheuristic optimization technique for load frequency control. SN Applied Sciences, 3 (2021). DOI: 10.1007/s42452-021-04482-y
- [41] N.R. Babu, S.K. Bhagat, L.C. Saikia, T. Chiranjeevi, R. Devarapalli and F.P.G. Márquez: A comprehensive review of recent strategies on automatic generation control/load frequency control in power systems. Archives of Computational Methods in Engineering, 30 (2023), 543-572. DOI: 10.1007/s11831-022-09810-y
- [42] K.W. Huang and Z.X. Wu: CPO a crow particle optimization algorithm. International Journal of Computational Intelligence Systems, 12(1), (2018), 426-435. DOI: 10.2991/ijcis.2018.125905658
Uwagi
1. The work reported herein was supported financially by the Ministerio de Ciencia e Innovación (Spain) and the European Regional Development Fund, under the Research Grant WindSound project (Reference: PID2021-125278OB-I00).
2. Opracowanie rekordu ze środków MNiSW, umowa nr POPUL/SP/0154/2024/02 w ramach programu "Społeczna odpowiedzialność nauki II" - moduł: Popularyzacja nauki (2025)
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-0753b578-c775-4d45-87a3-29ae655633d5
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.