PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Improving the mechanical properties of braided shape memory polymer stents by heat setting

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The aging population is one of the biggest challenges of the 21st century and so is the subsequent increase in patients with cardiovascular diseases. The state-of-the-art treatment for cardiovascular stenosis is an angioplasty in combination with stenting of the affected artery. Stents can be either laser cut out of a tube or an interwoven such as a braided structure. Furthermore, there are two groups of stents regarding their expansion behaviours: balloon expandable and self-expandable. Within this paper, a new approach to braiding stent-like structures out of a novel shape memory polymer fibre will be discussed. Furthermore, the heat treatment of the stent structure will be investigated to improve its characteristics such as radial stiffness.
Rocznik
Strony
73--76
Opis fizyczny
Bibliogr. 7 poz., il., wykr.
Twórcy
autor
  • Institut für Textiltechnik of RWTH Aachen University, Otto-Blumenthal-Str. 1, 52074 Aachen, Germany, Tel.: +49 241 80 23448, Fax.: +49 241 80 22422
autor
  • Institut fur Textiltechnik of RWTH Aachen University, Otto-Blumenthal-Str. 1, 52074 Aachen, Germany, Tel.: +49 241 80 23448, Fax.: +49 241 80 22422
autor
  • Internal Medicine I, University Hospital of RWTH Aachen University, Pauwelstr. 30, 52074 Aachen, Germany, Tel.: +49 241 80 89835, Fax.: 49 241 80 82545
autor
  • Internal Medicine I, University Hospital of RWTH Aachen University, Pauwelstr. 30, 52074 Aachen, Germany, Tel.: +49 241 80 89835, Fax.: 49 241 80 82545
autor
  • Internal Medicine I, University Hospital of RWTH Aachen University, Pauwelstr. 30, 52074 Aachen, Germany, Tel.: +49 241 80 89835, Fax.: 49 241 80 82545
autor
  • Institut fur Textiltechnik of RWTH Aachen University, Otto-Blumenthal-Str. 1, 52074 Aachen, Germany, Tel.: +49 241 80 23448, Fax.: +49 241 80 22422
Bibliografia
  • 1. Borchert F: Fertigung und Charakterisierung eines textilen Shape-Memory-Polymer-Stents. Institut für Textiltechnik Aachen, RWTH Aachen, Aachen 2007.
  • 2. Brüggemann D, Shape Memory Materialien in der Medizintechnik, Bayern Innovativ, Augsburg, 23. Mai 2006.
  • 3. Budillon F, Shape Memory Textiles, Shape Memory and superelastic technologies 2004 (SMST 2004), Baden-Baden 3.-7.10.2004, Vortrag-Nr. 171.
  • 4. Budillon F, Gries T, Nitinol textiles for medical applications,13th Intern. Techtextil Symposium, Frankfurt, 06.-09.06.2005.
  • 5. Houis S, Gries T, Weber C, Kelm M, Blindt R, Shape-memory polymers for vascular stent application, Proceedings BMT 2007 : 41. Jahrestagung der Deutschen Gesellschaft für Biomedizinische Technik (DGBMT) im VDE, Aachen 26.-29.09.2007; Biomedizinische Technik 52 ,Ergänzungsband, 2007.
  • 6. Lendlein A, Kelch S, Shape memory polymers, Angewandte Chemie International Edition, 41, 12, pp (2034-2057), 2002.
  • 7. Schreiber F, Ko FK, Yang HJ, Amalric E, Gries T, Novel three-dimensional braided textiles for medical and microcomposite applications, Küppers, B. (Ed.): Proceedings of the 3rd Aachen-Dresden International Textile Conference, Aachen, November 26-27, 2009. - Aachen : DWI an der RWTH Aachen e.V., 2009.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-05b66595-cdbc-4394-8454-de4c43e28789
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.