Geometry Optimalization of the Ventilated Insulating Panel

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
An EPS ventilated panel, which may be applied as an external insulation to humid walls, is investigated. Dimensions of the air channel sections have been determined using the ANSYS software. Afterwards, the drying rate of the walls externally insulated with EPS, mineral wool and EPS ventilated panel has been compared using the WUFI software. The ventilated panel increases the drying rate when compared with the standard polystyrene panel and increases the heat loss through the wall by less than 20%.
Rocznik
Strony
76--86
Opis fizyczny
Bibliogr. 9 poz., fot., rys., tab., wykr.
Twórcy
  • Izodom 2000 Polska
  • Izodom 2000 Polska
  • Lodz University of Technology, Department of Building Physics and Building Materials, Łódź, Poland
autor
  • Lodz University of Technology, Department of Building Physics and Building Materials, Łódź, Poland
  • Lodz University of Technology, Department of Building Physics and Building Materials, Łódź, Poland
Bibliografia
  • 1. Directive (EU) 2018/844 of the European Parliament and of the Council of 30 May 2018 amending Directive 2010/31/EU on the energy performance of buildings and Directive 2012/27/EU on energy efficiency.
  • 2. Khaled, K and Richman, R 2000. Thermal performance impacts of vented EIFS assemblies in the cold climate of Southern Ontario. Journal of Building Engineering 31.
  • 3. Nehdi, M 2001. Parametric study of moisture and heat transfer in a new rainscreen stucco wall. Journal of Building Physics 24, 335-347.
  • 4. Nizovtsev, MI, Belyi, VT and Sterlygov, AN. The façade system with ventilated channels for thermal insulation of newly constructed and renovated buildings. Energy and Buildings 75, 60-69.
  • 5. Borodulin, VY and Nizovtsev, MI 2014. Modeling heat and moisture transfer of building facades thermally insulated by the panels with ventilated channels. Journal of Building Engineering 40: 102391.
  • 6. Falk, J and Sandin, K 2013. Ventilated rainscreen cladding: Measurements of cavity air velocities, estimation of air change rates and evaluation of driving forces. Building and Environment 59, 164-176.
  • 7. Vanpachtenbeke, M, Langmans, J, Van den Bulcke, J, Van Acker, J and Roels, S 2017. On the drying potential of cavity ventilation behind brick veneer cladding: A detailed field study. Building and Environment 123, 133-145.
  • 8. Langmans, J, Desta, TZ, Alderweireldt, L and Roels, S 2016. Field study of the air change rate behind residential rainscreen cladding systems: a parameter analysis. Building and Environment 95, 1-12.
  • 9. ISO 13788:2012. Hygrothermal performance of building components and building elements – Internal surface temperature to avoid critical surface humidity and interstitial condensation – Calculation methods.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-05b56323-2b74-4e30-a559-ce777cca3662
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.