Long-term chemical stability of BaCe0,85Y0,15O3-δ + Ce0,85Y0,15O2-δ composite samples at room temperature and at 873 K for use in dual PCFC-SOFC fuel cells

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Długoczasowa stabilność próbek kompozytowych BaCe0,85Y0,15O3-δ + Ce0,85Y0,15O2-δ w temperaturze pokojowej oraz 873 K do zastosowania w ogniwach paliwowych typu PCF-SOFC
Języki publikacji
EN
Abstrakty
EN
The goal of this work is to compare the long-term chemical stability of BaCe0,85Y0,15O3-δ and Ce0,85Y0,15O2-δ bulk composite samples to that of pure BaCe0,85Y0,15O3-δ after ageing for 600 hours in CO2 /H2 O atmosphere at room temperature and N2 /H2 O atmosphere at 873 K. Differential Thermal Analysis and Thermogravimetry were used to investigate the physicochemical processes that took place during the ageing of the afore-mentioned samples and the chemical composition of the gases released from the samples was analyzed by a Mass Spectrometer. The influence of the reactive atmospheres on phase and chemical composition, as well as the microstructure of the bulk samples, was determined from X-ray Diffraction results and Scanning Electron Microscopy observations combined with Energy Dispersion Spectroscopy analysis. From these studies it can be concluded that the composite materials are capable of maintaining stability in the studied conditions, however, pure BaCe0,85Y0,15O3-δis unstable in CO2 /H2 O atmosphere at room temperature.
PL
Celem pracy jest porównanie długoczasowej stabilności chemicznej spieków kompozytowych BaCe0,85Y0,15O3-δ i Ce0,85Y0,15O2-δ z czystym BaCe0,85Y0,15O3-δ, które poddano starzeniu przez 600 godzin w atmosferze CO2 /H2 O w temperaturze pokojowej oraz w atmosferze N2 /H2 O w 873 K. Do badań procesów fizykochemicznych zachodzących podczas starzenia w/w próbek wykorzystano metodę termicznej analizy różnicowej oraz termograwimetrie, natomiast skład chemiczny gazów uwalnianych z próbek podczas ich ogrzewania analizowano spektrometrem masowym. Wpływ atmosfer reakcyjnych na skład fazowy i chemiczny oraz mikrostrukture spieków określono w oparciu o wyniki badań rentgenograficznych oraz obserwacji przy pomocy skaningowej mikroskopii elektronowej połączonej z dyspersją energii promieniowania rentgenowskiego. Z badań tych można wnioskować, że materiały kompozytowe wykazują stabilność w badanych warunkach, podczas gdy czysty BaCe0,85Y0,15O3-δ jest nietrwały w atmosferze CO2 /H2 O w temperaturze pokojowej.
Twórcy
autor
  • AGH University of Science and Technology, 30-059 Kraków, Poland
autor
  • Institute for Energgetics and Interphases, National Research Council, Genoa, Italy
  • AGH University of Science and Technology, 30-059 Kraków, Poland
Bibliografia
  • [1] W. Nernst, Z. Elektrochem. 6, 41 (1899).
  • [2] B. C. H. Steele, J. M. Floyd, Proc. Br. Ceram. Soc. 19, 55 (1971).
  • [3] M. P. Anderson, D. E. Cox, K. Halperin, A. S. Nowick, Solid State Ionics. 9-10, 953 (1983).
  • [4] D. Y. Wang, A. S. Nowick, J. Phys. and Chem. Solids. 44, 639 (1983).
  • [5] K. Fuda, K. Kishio, S. Yamauchi, K. Fueki, J. Phys. and Chem. Solids 46, 1141 (1985).
  • [6] F. A. Kroger, H. J. Vink, Solid State Phys. 3, 307 (1956).
  • [7] M. Hartmanova, E. E. Lomonova, V. Navratil, P. Sutta, F. Kundracik, J. Mater. Sci. 40, 5679 (2005).
  • [8] N. Q. Minh, J. Am. Ceram. Soc. 76, 563 (1993).
  • [9] H. Iwahara, T. Esaka, H. Uchida, N. Maeda, Solid State Ionics. 3-4, 359 (1981).
  • [10] H. Iwahara, H. Uchida, K. Ono, K. Ogaki, J. Electrochem. Soc. 135, 529 (1988).
  • [11] T. Yajima, H. Kazeoka, T. Yogo, H. Iwahara, Solid State Ionics. 47, 271 (1991).
  • [12] H. Iwahara, T. Yajima, T. Hibino, K. Ozaki, H. Suzuki, Solid State Ionics. 61, 65 (1993).
  • [13] T. Hibino, A. Hashimoto, M. Suzuki, M. Sano, J. Electrochem. Soc. 149, A1503 (2002).
  • [14] T. Shimura, H. Tanaka, H. Matsumoto, T. Yogo, Solid State Ionics. 176, 2945 (2005).
  • [15] W. Suksamai, I. S. Metcalfe, Solid State Ionics. 178, 627 (2007).
  • [16] X. Z. Fu, J. L. Luo, A. R. Sanger, N. Luo, K. T. Chuang, J. Power Sources. 195, 2659 (2010).
  • [17] G. Chiodelli, L. Malavasi, C. Tealdi, S. Barison, M. Battagliarin, L. Doubova, M. Fabrizio, C. Mortalo, R. Gerbasi, J. Alloy Compd. 470, 477 (2009).
  • [18] S. Gopalan, A. V. Virkar, J. Electrochem. Soc. 140, 1060 (1993).
  • [19] C. W. Tanner, A. V. Virkar, J. Electrochem. Soc. 143, 1386 (1996).
  • [20] K. Katahira, Y. Kohchi, T. Shimura, H. Iwahara, Solid State Ionics. 138, 91 (2000).
  • [21] P. Sawant, S. Varma, B. N. Wani, S. R. Bharadwaj, Int. J. Hydrogen Energy. 37, 3848 (2012).
  • [22] P. Pasierb, E. Drożdż-Cieśla, R. Gajerski, S. Łabus, S. Komornicki, M. Rekas, J. Therm. Anal. Calor. 96, 475 (2009).
  • [23] K. Xie, R. Yan, X. Liu, J. Alloys Comp. 479, L40 (2009).
  • [24] A. S. Thorel, M. Chesnaud, M. Viviani, A. Barbucci, S. Presto, P. Piccardo, Z. Ilhan, D. Vladikova, Z. Stoynov, ECS Trans. 25, 753 (2009).
  • [25] G. Caboche, J.-F. Hochepied, P. Piccardo, K. Przybylski, R. Ruckdäschel, M.-R. Ardigó, E. Fatome, S. Chevalier, A. Perron, L. Combemale, M. Palard, J. Prażuch, T. Brylewski, ECS Trans. 25, 763 (2009)
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-045243f0-44ee-4c47-8865-8f7da9a780ed
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.