Modeling of mechanical phenomena in the platinum-chromium coronary stents

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
This study discusses the geometrical model of a coronary stent with known design and strength analysis using the finite element method. The coronary stent model was made of platinum and chromium alloy. Static analysis based on compression of the coronary stent was also performed. The aim of the analysis was to examine the strength of the stent structure. The study analyzed stresses, plastic strains and displacements after applying a constant load to the stent walls. The mechanical phenomena such as percentage degree of shortening (foreshortening), relative narrowing and area of stent covering were also determined.
Rocznik
Strony
29--36
Opis fizyczny
Bibliogr. 11 poz., rys., tab.
Twórcy
  • Institute of Mechanical Technology, Czestochowa University of Technology Czestochowa, Poland
  • Student Scientific Society of Biomedical Engineering, Institute of Mechanical Technology Czestochowa University of Technology, Czestochowa, Poland
autor
  • Student Scientific Society of Biomedical Engineering, Institute of Mechanical Technology Czestochowa University of Technology, Czestochowa, Poland
Bibliografia
  • [1] Paszenda Z., Stenty w kardiologii interwencyjnej. Wybrane zagadnienia, Wydawnictwo Politechniki Śląskiej, Gliwice 2013 (in Polish).
  • [2] Paszenda Z., Kształtowanie własności fizykochemicznych stentów wieńcowych ze stali Cr-Ni-Mo do zastosowań w kardiologii zabiegowej, Wyd. Politechniki Śląskiej, Gliwice 2005 (in Polish).
  • [3] Idziak-Jabłońska A., Numerical analysis of mechanical phenomena in coronary stent made of titanium alloy Ti-13Nb-13Zr, Key Engineering Materials 2016, 687, 191-198.
  • [4] O’Brien B.J., Stinson J.S., Larsen S.R., Eppihimer M.J., Carroll W.M., A platinum-chromium steel for cardiovascular stents, Biomaterials 2010, May 31(14), 3755-3760.
  • [5] Paszenda Z., Stenty w chirurgii małoinwazyjnej, Wydawnictwo Politechniki Śląskiej, Gliwice 2006 (in Polish).
  • [6] Annicchiarico W., Dulikravich GS., Multiobjective nonlinear shape optimization of stent based on evolution principles. Inverse Problems, Design and Optimization Symposium, Miami, Florida, U.S.A., April 16-18, 2007.
  • [7] Li N., Zhanga H., Oyyang H., Shape optimization of coronary artery stent based on a parametric model. Finite Elements in Analysis and Design 2009, 45, 468-475.
  • [8] Norma PN-EN ISO 25539-2 Implanty sercowo-naczyniowe - Wyroby wewnątrznaczyniowe - Część 2: Stenty naczyniowe.
  • [9] Idziak-Jabłońska A., Lacki P., Major R., Effect of material and geometry on Dogboning in coronary stent, Inżynieria Materiałowa 2013, 4, lipiec-sierpień, 269-272.
  • [10] Idziak-Jabłońska A., Modelowanie zjawisk mechanicznych w stentach wieńcowych na podstawie analizy numerycznej, Mechanik 2015, 7, 303-310 (in Polish).
  • [11] Zienkiewicz O.C., Taylor R.L., The Finite Element Method, vol. 1-3, Butterworth-Heinemann, Oxford 2000.