Content available remote Numerical Simulation of O3and NO Reacting in a Tubular Flow Reactor
100%
EN
A process capable of NOx control by ozone injection gained wide attention as a possible alternative to proven post combustion technologies such as selective catalytic (and non-catalytic) reduction. The purpose of the work was to develop a numerical model of NO oxidation with O3 that would be capable of providing guidelines for process optimisation during different design stages. A Computational Fluid Dynamics code was used to simulate turbulent reacting flow. In order to reduce computation expense a 11-step global NO - O3 reaction mechanism was implemented into the code. Model performance was verified by the experiment in a tubular flow reactor for two injection nozzle configurations and for two O3/NO ratios of molar fluxe. The objective of this work was to estimate the applicability of a simplified homogeneous reaction mechanism in reactive turbulent flow simulation. Quantitative conformity was not completely satisfying for all examined cases, but the final effect of NO oxidation was predicted correctly at the reactor outlet.
EN
The paper presents presents the possibility of using the ozonation process in coke wastewater treatment. The wastewater produced during processing of coke was initially pre-treated mechanically in order to remove solid impurities, oils and tar substances. The raw wastewater was characterized by the phenolic odor, brown color and alkaline pH (pH 9.2). The COD value of raw wastewater was 8100 mg/dm3 and the value of BOD was very low (180 mg/dm3). A high concentration of total nitrogen (2420 mg/dm3) and TOC (2240 mg/dm3) was also noted. The study was conducted in three stages. In the first stage, coking wastewater was treated only by ozone, the dose of which varied from 10 mg/dm3 to 40 mg/dm3. The effect of pH during ozonation process was determined on TOC removal efficiency. For all of the pH values (pH = 3.5, pH = 7, pH = 8.5 and pH = 11.5) the TOC removal rate constant was determined. In the second stage, the rate OH radicals generation was accelerated by the addition of hydrogen peroxide to the reactor. The ratio by weight of COD: H2O2 was 1:2.5, 1:5, 1:10 and 1:20. In the last stage of the study, we attempted to assist the ozonation process with ultrasonic field. The sonication time was 8 minutes and the amplitude was 61.5 μm. It was found that the ozonation process is the most effective at alkaline pH (8.5). The TOC removal efficiency was 34% (1470 mg/dm3) after 60 minutes of ozonation. The best results of oxidation of pollutants measured as COD and TOC removal were observed when the dose of ozone was 30 mg/dm3.The combination of sonication and ozonation has resulted in a reduction of COD and TOC values by 1000 mg/dm3 and 300 mg/dm3, respectively, in comparison to ozonation process alone. It was found that the most effective process in coke wastewater treatment is the combination of ozonation with hydrogen peroxide addition (COD:H2O2=1:10). The COD, TOC and BOD value were 54%, 35% and 20% lower, respectively, in comparison to ozonation process conducted alone.
|
|
tom Nr 10
80--85
PL
W artykule opisano obiekt basenowy, w którym w czterech instalacjach nie zostały spełnione wymagania dotyczące zawartości chloru związanego. Przeprowadzone kontrolne badania bakteriologiczne zdyskwalifikowały wodę we wszystkich obiegach przeznaczonych dla osób kąpiących się. Podejmowano różne działania naprawcze, m.in. zwiększenie częstotliwości płukania filtrów z ich przechlorowaniem. Jednak dopiero wykorzystanie układu mobilnego ozonowania z wprowadzeniem wody wysoko ozonowanej przed filtracją i płukanie instalacji cyrkulacyjnej zbiorników pozwoliło na likwidację zagrożenia bakteriologicznego oraz utrzymanie zawartości chloru związanego na poziomie wymaganym przez przepisy, tj. poniżej 0,3 mg Cl2/dm.
EN
In the analyzed facility, I fail to meet the requirements for four pool water installations analyzing chlorine level. The bacteriological control tests disqualified the water in all circulation installations. The service staff take various corrective actions like an increased frequency of filter rinsing with their overhauling and other repair methods offered by the market. Only the use of a mobile ozonation system, introduction highly ozonized water before filtration and rinsing of the tank circulation system allows eliminating the bacteriological threat and maintaining the chlorine content at a level below 0,3 mg Cl2/dm.
PL
Przedstawiono wyniki badań nad utlenianiem 5-fluorouracylu oraz nad oczyszczaniem ścieków powstałych przy produkcji maści Efudix - 5%, zawierającej ten związek jako składnik aktywny. Utlenianie 5-fluorouracylu prowadzono metodą ozonowania przy pH = 12 i 13 oraz metodą O3/H2O2. Ponieważ najbardziej efektywna okazała się metoda ozonowania przy pH = 13, do badań nad oczyszczaniem ścieków zastosowano tylko tę metodę. Osiągnięto wysoki stopień redukcji wartości ChZT oraz pełny i szybki rozkład 5-fluorouracylu, rozpoczynający się od oderwania atomu fluoru od molekuły.
EN
The process of oxidation of 5-flurouracil and the treatment of wastewater from Efudix ointment production were investigated. 5-fluorouracil was oxidized by ozonation at pH = 12 and 13 and by O3/H2O2 method. Because the ozonation at pH = 13 proved to be the most effective method, this method was applied to the wastewater treatment. The high degree of COD reduction was achieved and 5-fluorouracil was completely and quickly destroyed. The process was initiated by fluorine detachment.
EN
Landfilling is the main method of waste disposal in Poland as well as in most countries all over the world. Leachate originating during waste deposition may be a source of ground water pollution. The aim of the paper was to characterize and compare the composition of leachate originating from three landfills in Lublin Province (Poland) and differing in their methods of waste pre-treatment. Ozonation was used in the initial trials to treat landfill leachate. Experiments were carried out to determine whether ozonation using a single dose of 1.8 gO3/m3 has the same effect on the efficiency of organic removal from leachates characterized by different ages and degrees of solid waste pre-treatment. From analyses (BOD5, COD, N-NH4, heavy metals) it was concluded, that excluding some fractions (glass, paper, plastics, aluminum, fine organic fraction) from the waste mass affects the leachate quality. The studied oxidizing method was found to influence the BOD5 and COD levels
PL
Dwa granulowane węgle aktywne (Filtrasorb 300 i ROW 0.8 Supra) po odmyciu wodą destylowaną poddano działaniu ozonu (w obecności wody lub w fazie gazowej) oraz nadtlenku wodoru. W przypadku próbek węgla aktywnego odmytych wodą, w oparciu o niskotemperaturowe izotermy adsorpcji azotu, określono pole powierzchni właściwej (BET), całkowitą objętość porów, pole powierzchni zewnętrznej i objętość mikroporów. Zmiany w chemii powierzchni węgla aktywnego określono na podstawie ubytku masy podczas termograwimetrycznego (krzywe TG) ogrzewania w zakresie temperatur 150÷600 oC i badań spektroskopowych FTIR. Następnie wyznaczono izotermy adsorpcji 4-chlorofenolu z rozcieńczonych roztworów wodnych na wszystkich otrzymanych preparatach węglowych. Na podstawie otrzymanych wyników badań przeanalizowano i poddano dyskusji wpływ zmian właściwości powierzchni próbek węgla aktywnego na adsorpcję polarnej substancji organicznej (4-chlorofenol) z roztworów wodnych.
EN
After washing with distilled water, two granular active carbons (Filtrasorb 300 and ROW 0.8 Supra) were exposed to ozone (in the presence of water or in the gas phase) and hydrogen peroxide. For the water washed samples of the activated carbons, specific surface area (BET), total pore volume, external surface area and micropore volume were determined from the low-temperature N2 adsorption isotherms. Changes in the chemistry of the active carbon surface were evaluated in terms of mass loss during thermogravimetric (TG curves) heating over the temperature range 150-600 oC and by FTIR spectroscopy. After that, the isotherms of 4-chlorophenol adsorption from the aqueous solutions were determined for all the carbon preparations examined. Following the interpretation of the results obtained, the effect of the changes in the surface properties of the active carbon samples on the adsorption of a polar organic substance (4-chlorophenol) from aqueous solutions was made subject to detailed analysis and discussion.
PL
Przeprowadzono proces ozonowania wysokoobciążonego (barwnikami, detergentami i solami mineralnymi) strumienia rzeczywistych ścieków włókienniczych. Dawka ozonu: 1,68 g×dm-3 pozwalała na 32% redukcję barwy już po 10 minutach. Po godzinie ozonowania uzyskano 85% odbarwienia, 13%-owy ubytek ChZT i spadek BZT5 o blisko 16%. Znikoma mineralizacja zanieczyszczeń i znakomite efekty odbarwiania rekomendują ozonowanie jako metodę towarzyszącą innym technikom oczyszczania. Stosunek BZT5/ChZT dowodzi, że ozonowanie wyraźnie nie pogarsza biodegradowalności tych ścieków, a krótki proces nawet poprawia tę zależność.
EN
Ozonation process was carried out for real textile wastewater stream with a high content of dyes, detergents and mineral salts. The ozone dose: 1.68 g×dm-3 allowed for 32% reduction in color after 10 minutes. After one hour the ozone discoloration obtained 85%, 13% loss of COD and 16% of BOD5.Mineralization was not satisfactory, but the excellent discoloration results recommend ozonation as the associated method for textile wastewater purification techniques. The ratio of BOD5/COD shows that ozone not explicitly worsens biodegradability of wastewater and the short process even improves this feature.
EN
C.I. Reactive Black 5 (RB5) is the most commonly used dye in the textile industry. Ozone is a strong oxidan that can decompose many barely degradable pollutants, including dyes. Although there are many literature reports devoted to the treatment of textile wastewater and dye solutions by ozone, the ozonation mechanism and modeling of the kinetics is still not well covered. In this work a kinetic model of the process of RB5 decolourisation by ozone has been proposed and validated on the basis of experimental data. The experiments were carried out in a liquid-liquid system to avoid mass transfer limitation. A model was established for acid reaction medium. The main RB5 reaction was direct oxidation of the dye with molecular ozone. The self-decomposition of ozone in liquid phase was taken into account and described by an empirical equation. The reaction rate constants of RB5 with ozone were estimated from the experimental data in the range of (1.88 ± 0.08) × 104 – (2.53 ± 0.10) × 105 M-1s-1 (invariant with initial dye concentration). An empirical equation k′ 2 = 1.06 × 108(COH−)0.31 was built for the constant to make it dependent on the pH value. A solution of the non-linear inverse problem allowed for identification of the kinetic constants on the basis of the experimental data obtained. The model gave a good match between the prediction and experimental data for pH between 1.88 and 4.0.
PL
Reactive Black 5 (RB5) jest powszechnie stosowanym barwnikiem w przemyśle włókienniczym. Ozon, będący silnym utleniaczem, jest w stanie rozłożyć wiele trudno degradowalnych substancji w tym barwniki. Pomimo, iż oczyszczanie ścieków włókienniczych i roztworów barwników ozonem było tematem wielu pozycji literaturowych, niewiele pośród nich dotyczyło badań nad poznaniem mechanizmu utleniania oraz modelowania kinetyki tego procesu. W niniejszej pracy zaproponowano matematyczny model opisujący kinetykę procesu odbarwiania barwnika RB5 za pomocą ozonu. Walidacji dokonano poprzez porównanie wyników modelowania do danych eksperymentalnych. Eksperymenty prowadzono w układzie homogenicznym ciecz-ciecz, aby uniknąć limitacji transferu masy między fazami układu. Model został opracowany dla procesu przebiegającego w środowisku kwaśnym, gdzie główną reakcją było bezpośrednie utlenianie barwnika cząsteczkowym ozonem z jednoczesnym uwzględnieniem rozkładu ozonu w fazie ciekłej. Model opisano równaniem empirycznym. Wartości stałych szybkości reakcji RB5 z ozonem oszacowane na podstawie danych eksperymentalnych znajdowały się w zakresie od do M-1s-1 i były niezależne od początkowego stężenia substratu. W celu uzależnienia stałych szybkości od wartości pH, wyznaczono zależność empiryczną w postaci. Rozwiązanie nieliniowego problemu odwrotnego pozwoliło na identyfikację stałych kinetycznych na podstawie danych eksperymentalnych. Otrzymano dobrą zgodność pomiędzy wynikami modelowania a danymi doświadczalnymi dla wartości pH w zakresie 1,88-4,0.
EN
A process capable of NOx control by ozone injection gained wide attention as a possible alternative to proven post combustion technologies such as selective catalytic (and non-catalytic) reduction. The purpose of the work was to develop a numerical model of NO oxidation with O3 that would be capable of providing guidelines for process optimisation during different design stages. A Computational Fluid Dynamics code was used to simulate turbulent reacting flow. In order to reduce computation expense a 11-step global NO - O3 reaction mechanism was implemented into the code. Model performance was verified by the experiment in a tubular flow reactor for two injection nozzle configurations and for two O3/NO ratios of molar fluxe. The objective of this work was to estimate the applicability of a simplified homogeneous reaction mechanism in reactive turbulent flow simulation. Quantitative conformity was not completely satisfying for all examined cases, but the final effect of NO oxidation was predicted correctly at the reactor outlet.
EN
Cyanobacteria can produce toxins and are also responsible for the taste and odour of water, which significantly impairs its quality. Removal of cyanobacterial cells with their intracellular compounds during water treatment not only improves the taste and odour of the treated water, but also reduces the concentration of toxic metabolites. In the present study, the ozonation of water in pretreatment plant near Sulejów artificial lake was tested. The concentrations of MCYST-LR and other isoforms of this hepatotoxin were determined at different steps of the pretreatment process by SPE and RP-HPLC methods.
PL
Sinice mogą produkować toksyny, związki pogarszające smak i dające nieprzyjemny zapach, obniżając w ten sposób jakość wody. Usuwanie komórek sinicowych wraz z ich produktami wewnątrzkomórkowymi w czasie procesu uzdatniania wody zmniejszy stężenie substancji smakowych i zapachowych oraz toksycznych metabolitów w uzdatnianej wodzie. Przedstawiono ozonowanie w stacji wstępnego uzdatniania wody znajdującej się w pobliżu zbiornika zaporowego w Sulejowie. Stężenie MCYST-LR i innych izoform tej hepatotoksyny w wodzie oznaczano techniką RP-HPLC po wstępnym oczyszczaniu i zatężaniu próby metodą SPE.
|
|
tom Vol. 40, nr 1
21-–38
EN
The paper focuses on the modelling of bromate formation. An axial dispersion model was proposed to integrate the non-ideal mixing, mass-transfer and a kinetic model that links ozone decomposition reactions from the Tomiyasu, Fukutomi and Gordon (TFG) ozone decay model with direct and indirect bromide oxidation reactions, oxidation of natural organic matter and its reactions with aqueous bromine. To elucidate the role of ammonia an additional set of reactions leading to bromamine formation, oxidation and disproportionation was incorporated in the kinetic model. Sensitivity analysis was conducted to obtain information on reliability of the reaction rate constants used and to simplify the model.
PL
Kukurydza jest jedną z najważniejszych roślin uprawnych świata, a jednocześnie idealnym siedliskiem dla rozwoju grzybów toksynotwórczych. Ich rozwój na powierzchni i wewnątrz ziarna warunkuje jego wilgotność oraz czas przechowywania. W przeprowadzonych badaniach podjęto próbę określenia czasu niezbędnego do efektywnego usuwania zanieczyszczenia aflatoksynami oraz skażenia grzybami pleśniowymi ziarna kukurydzy o podwyższonej wilgotności – 24%. Proces ozonowania prowadzono przy zastosowaniu ozonu w stężeniu 2 mg·dm–3 przez 15, 30, 60, 120 i 180 minut. Oznaczenie ilościowe grzybów przeprowadzono zgodnie z PN-R-64791. Zawartość sumy aflatoksyn zbadano metodą immunoenzymatyczną – ELISA. Przeprowadzone badania wykazały, że zastosowanie gazowego ozonu powoduje blisko stuprocentowe zmniejszenie ogólnej liczby grzybów pleśniowych i produkowanych przez nie aflatoksyn w wilgotnym ziarnie kukurydzy. 38% redukcję zanieczyszczenia grzybami i 42% obniżenie poziomu aflatoksyn obserwowano już po 15 minutach prowadzenia procesu ozonowania. Wydłużenie czasu działania ozonudo 180 minut spowodowało odpowiednio 99% i 92% redukcję grzybów pleśniowych i aflatoksyn. Przeprowadzone badania wykazały, że ozonowanie jest efektywnym sposobem zmniejszania zanieczyszczenia mikrobiologicznego surowca i należy do obiecujących, stosunkowo tanich metod zabezpieczenia ziarna kukurydzy przed dalszymi procesami biodegradacji.
EN
Corn is one of the most important crop in the world and also the ideal habitat for the growth of fungi. Their growth on the surface and inside the grain depends on the moisture content and determines its shelf life. The present study attempted to determine the time required for the efficient removal of fungi and aflatoxin contamination of corn grain with 24% humidity. The ozonation process was carried out using the ozone concentration of 2 mg dm–3 for 15, 30, 60, 120 and 180 minutes. Quantification of fungi was carried out in accordance with PN-R-64791. The total aflatoxin content was tested using the immunoassay – ELISA. The study showed that the use of ozone gas causes nearly one hundred percent reduction in the total number of fungi and aflatoxins produced by them in a damp grain corn. 38% reduction of fungi contamination and 42% in aflatoxin level was observed after 15 minutes of operation. Extension of the contact time for 180 minutes resulted in 99% and 92% reduction respectively. Ozone treatment is effective tool in reducing the microbial load of raw material and is a promising, relatively inexpensive way to protect the raw material before any further processing.
14
Content available remote The role of selected technological processes in drinking water treatment
58%
|
|
tom Vol. 16, no. 2
189--200
EN
The selection of appropriate technological processes for water treatment has a key impact on the qualitative safety of water intended for human consumption. The article analyzes water treatment processes used in a selected Water Treatment Plant (WTP) in terms of surface and ground water treatment. Five-year results of the research are presented on selected physico-chemical and bacteriological parameters of water quality before treatment processes, after individual stages of treatment (settling tanks, DynaSand® filters, ozonation, carbon filters, UV rays and chlorine gas disinfection). The reduction of key pollutants at individual stages of technological processes was calculated. The results of the analyzes demonstrated that the technological processes used in WTP effectively remove turbidity, color, UVA254nm, permanganatate oxygen demand, Fetotal, Mn, coliform bacteria, Enterococcus faecalis and Clostridium Perfringens from the surface and underground water. Studies have shown that infiltration in the ground effectively removes selected pollutants from water and its effectiveness is comparable to high-efficiency treatment processes.
PL
Przedstawiono wyniki wieloletnich badań zawartości trójhalometanów (THM), kwasów halogenooctowych (HAA) i bromianów (BrO3-) w wodzie wodociągowej w Białymstoku. Wykazano, że w czasie gdy stosowano wstępne chlorowanie zawartość chloroformu w wodzie była bardzo duża (155÷194 mg/m3), maks. 240 mg/m3 w 1995 r. W 1998 r., po zmianie wstępnego chlorowania na ozonowanie, zawartość chloroformu wynosiła 12,2÷90,4 mg/m3 (średnio 36,6 mg/m3), a suma trójhalometanów (TTHM) wynosiła 13,8÷96,7 mg/m3. W kolejnych latach ilość chloroformu systematycznie malała z ponad 200 mg/m3 (1995-1996), poprzez 65 mg/m3 (2006) aż do poniżej 20 mg/m3 (2009-2010). Jednocześnie suma kwasów halogenooctowych (THAA) zmalała z 8,4÷126,6 mg/m3 (2004-2006) do 4,4÷13,4 mg/m3 (2009-2010). Zawartość bromianów po wprowadzeniu ozonowania nigdy nie przekroczyła dopuszczalnej ilości 10 mgBrO3-/m3, a najczęściej była poniżej 5 mgBrO3-/m3, przy ilości bromków w ujmowanej wodzie 10,4÷23,0 gBr-/m3. Przeprowadzona analiza zmian jakości wody wodociągowej wykazała, że modernizacja zakładu oczyszczania wody spowodowała systematyczną poprawę jej jakości w odniesieniu do zawartości niebezpiecznych dla zdrowia produktów utleniania, takich jak THM, HAA i bromiany.
EN
The paper summarizes the results of many years' investigations into the occurrence of trihalomethanes (THM), haloacetic acids (HAA) and bromates (BrO3-) in the municipal water of Bialystok. Analysis of the data ob-tained has produced the following findings. Over the period when use was made of pre-chlorination, the chloroform content of the water was very high (155 to 194 mg/m3), with a maximal value of 240 mg/m3 in 1995. In 1998, when pre-chlorination was replaced with pre-ozonation, chloroform content varied from 12.2 mg/m3 to 90.4 mg/m3 (36.6 mg/m3 on average), and the sum of trihalomethanes (TTHM) from 13.8 to 96.7 mg/m3. In subsequent years the quantity of chloroform decreased continuingly from 200 g/m3 (1995-1996), through 65 mg/m3 (2006), to a level lower than 20 mg/m3 (2009-2010). Over this period, the sum of haloacetic acids (THAA) fell from 8.4-126.6 g/m3 (2004-2006) to 4.4-13.4 mg/m3 (2009-2010). Upon introduction of the ozonation process, bromate content did not exceed the admissible value of 10 mgBrO3-/m3, and in most instances its concentration in the tap water was lower than 5 mgBrO3-/m3, the quantity of bromides in raw water ranging between 10.4 and 23.0 gBr-/m3. Analysis of the changes in the quantity of ozonation and chlorination by-products makes it clear that the modernization of the water treatment plant has noticeably improved tap water quality primarily with respect to the content of substances carrying serious health implications - THMs, HAAs and bromates.
|
|
tom Vol. 40, nr 1
39–47
EN
Validation results of a theoretical model that describes the formation of bromate during ozonation of bromide-containing natural waters are presented. An axial dispersion model integrating the nonideal mixing, mass-transfer and a kinetic model that links ozone decomposition reactions from the Tomiyasu, Fukutomi and Gordon ozone decay model with direct and indirect bromide oxidation reactions, oxidation of natural organic matter and reactions of dissolved organics and aqueous bromine was verified. The model was successfully validated with results obtained both at a laboratory and a full scale. Its applicability to different water supply systems was approved.
|
|
tom Vol. 38, no. 2
103-109
EN
The paper describes the effectiveness of mycoestrogen removal in an integrated ozonation - nanofiltration system for water treatment. The results were compared to those obtained for ozonation and nanofiltration carried out as single processes. It has been found that the effectiveness of mycoestrogen removal in the integrated system was higher than that observed for single ozonation. During ozonation, the removal of micropollutants was affected by the dose of an oxidizing agent and type of treated water. As far as nanofiltration is concerned, its effectiveness both in the integrated system and as a single process was similar. Nevertheless, it is advisable to precede nanofiltration with ozonation because of membrane efficiency.
PL
W pracy przedstawiono efektywność usuwania mykoestrogenów w zintegrowanym układzie oczyszczania wody ozonowanie - nanofiltracja. Wyniki badań porównano do wyników uzyskanych podczas ozonowania i nanofiltracji, które realizowane były jako procesy pojedyncze. Określono, że efektywność usuwania mykoestrogenów w układzie zintegrowanym jest wyższa niż obserwowana w pojedynczym procesie ozonowania. W przypadku ozonowania na usuwanie mikrozanieczyszczeń ma wpływ dawka utleniacza i rodzaj oczyszczanej wody. Z kolei efektywność nanofiltracji realizowanej jako proces pojedynczy i w układzie zintegrowanym pod kątem usuwania mykoestrogenów była zbliżona. Jednak biorąc pod uwagę wydajność membrany korzystniej jest proces nanofiltracji poprzedzić procesem ozonowania wody.
18
Content available Ozon und Holz
58%
PL
Przeanalizowano problemy związane z dotrzymaniem standardów jakości wody wprowadzanej do miejskiej sieci wodociągowej przez Zakład Wodociągu Praskiego MPWiK w m.st. Warszawie SA oraz utrzymaniem stabilności biologicznej wody w systemie dystrybucji. Ponieważ eksploatowany układ technologiczny oczyszczania wody (ujęcie infiltracyjne z Wisły - filtracja pospieszna przez złoża piaskowe - dezynfekcja) ma ograniczone możliwości ciągłego zapewnienia wysokiej jakości wody czystej, w ostatnich latach przeprowadzono badania pilotowe nad określeniem kierunków modernizacji Wodociągu Praskiego. W pracy przedstawiono skuteczność oczyszczania wody uzyskaną w wyniku próby rozbudowy obecnego układu technologicznego o procesy koagulacji powierzchniowej solami glinu i żelaza, wymiany jonowej na żywicy oraz ozonowania skojarzonego z sorpcją na granulowanym węglu aktywnym.
EN
The object under study is Wodociag Praski (Praski Water Treatment Plant), a department of the Municipal Water and Sewerage Enterprise, Warsaw. The key issues addressed include the quality of the water supplied to the water-pipe network (the problem of whether relevant standards are met) and biological stability of the water in the distribution system. The treatment train being used (infiltration water intake from the Vistula; rapid filtration, sand filters; disinfection) offers limited guarantee that high-quality water will be supplied continually. In recent years, a pilot study has been conducted with the aim of determining the directions in the modernization of the Praski WTP. The present paper describes the treatment effects that can be achieved when the existing treatment train is extended by the addition of the following unit processes: surface coagulation with alum and iron salts, ion exchange on the MIEX resin, and ozonation-sorption on granular active carbon.