Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl

PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
2008 | 14 | 3 | 163-182
Tytuł artykułu

Assesing multileaf collimator effect on the build-up region using Monte Carlo method

Treść / Zawartość
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Previous Monte Carlo studies have investigated the multileaf collimator (MLC) contribution to the build-up region for fields in which the MLC leaves were fully blocking the openings defined by the collimation jaws. In the present work, we investigate the same effect but for symmetric and asymmetric MLC defined field sizes (2×2, 4×4, 10×10 and 3×7 cm2). A Varian 2100C/D accelerator with 120-leaf MLC is accurately modeled for a 6MV photon beam using the BEAMnrc/EGSnrc code.Our results indicate that particles scattered from accelerator head and MLC are responsible for the increase of about 7% on the surface dose when comparing 2×2 and 10×10 cm2 fields. We found that the MLC contribution to the total build-up dose is about 2% for the 2×2 cm2 field and less than 1% for the largest fields.
Słowa kluczowe
Wydawca

Rocznik
Tom
14
Numer
3
Strony
163-182
Opis fizyczny
Daty
wydano
2008-01-01
online
2009-04-14
Twórcy
autor
autor
autor
autor
  • Centro de Fisica Nuclear da Universidade de Lisboa, Lisboa, Portugal
Bibliografia
  • Heath E, Seuntjens J. Development and validation of a BEAMnrc component module for accurate Monte Carlo modelling of the Varian dynamic Millenium multileaf collimator. Phys Med Biol. 2003; 48: 4045-4063.[WoS][Crossref]
  • Jang SY, Vassiliev ON, Liu HH, Mohan R, Siebers JV. Development and commissioning of a multileaf collimator model in Monte Carlo dose calculations for intensity-modulated radiation therapy. Med Phys. 2006; 33(3): 770-781.[Crossref][PubMed]
  • Kim JO, Siebers JV, Keall PJ, Arnfield MR, Mohan R. A Monte Carlo study of radiation transport through multileaf collimators. Med Phys. 2001; 28: 2497-2506.[Crossref][PubMed]
  • Mora GM, Maio A, Rogers DWO. Monte Carlo Simulation of a Typical 60Co Therapy Source. Med Phys. 1999; 26: 2494-2502.[Crossref]
  • Rogers DWO, Walters B, Kawrakow I. BEAMnrc Users Manual. Ottawa: National Research Council of Canada; 2005. Report PIRS-0509(A)revK.
  • Walters B, Kawrakow I, Rogers DWO. DOSXYZnrc Users Manual. Ottawa: National Research Council of Canada; 2005. Report PIRS-794revB.