PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Czasopismo
2014 | 12 | 11 | 1127-1132
Tytuł artykułu

Determination of 210Po content of vietnamese tobacco samples

Treść / Zawartość
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Smoking is one of the leading causes of preventable death. In recent years, numerous countries have initiated the prohibition of smoking in restaurants, workplaces and public spaces. The Vietnamese government intends to follow the precautions against public smoking as well. Over and above the number of some hazardous chemical components found in tobacco, 210Po isotope content could enhance the probability of the development of lung cancer. In this study 14 Vietnamese tobacco products (commercial cigarettes and pipe tobacco) 210Po activity concentration were determined using PIPS semiconductor alpha spectrometry. The results showed that the 210Po activity concentration of the investigated samples varied between 7.40 ± 1.09–128.64 ± 11.22 mBq g−1. The average 210Po content of commercial cigarettes was 15.5 mBq g−1, whilst the average of pipe tobacco was 20.4 mBq g−1. To estimate the risk of inhalation of 210Po isotopes originating as a result of smoking, dose estimations were carried out.
Słowa kluczowe
Wydawca

Czasopismo
Rocznik
Tom
12
Numer
11
Strony
1127-1132
Opis fizyczny
Daty
wydano
2014-11-01
online
2014-05-15
Twórcy
  • Social Organisation for Radioecological Cleanliness
autor
  • University of Pannonia
autor
  • Institute for Nuclear Science and Technology
autor
  • Institute for Nuclear Science and Technology
Bibliografia
  • [1] Report on the Global Tobacco Epidemic, The MPOWER package (World Health Organization, Geneva, 2008)
  • [2] T.C. Tso, I. Fisenne, Radiat. Bot. 8, 457 (1968) http://dx.doi.org/10.1016/S0033-7560(68)80107-3[Crossref]
  • [3] P.E. Figgins, The Radiochemistry of Polonium, Technical report (1961)
  • [4] E.P. Radford Jr., V.R. Hunt, Science 143, 247 (1964) http://dx.doi.org/10.1126/science.143.3603.247[Crossref]
  • [5] T.F. Kelley, Science 149, 537 (1965) http://dx.doi.org/10.1126/science.149.3683.537[Crossref]
  • [6] L. Robyn, J.E. Prueitt, P.A. Goodman, J. Environ. Radioactiv. 100, 157 (2009) http://dx.doi.org/10.1016/j.jenvrad.2008.11.008[Crossref]
  • [7] B.S. Cohen, N.H. Harley, T.C. Tso, Toxicol. Appl. Pharm. 79, 314 (1985) http://dx.doi.org/10.1016/0041-008X(85)90353-9[Crossref]
  • [8] D.T. Levy, S. Bales, N.T. Lam, L. Nikolayev, Soc. Sci. Med. 62, 1819 (2006) http://dx.doi.org/10.1016/j.socscimed.2005.08.043[Crossref]
  • [9] L.A. Currie, Anal. Chem. 40, 586 (1968) http://dx.doi.org/10.1021/ac60259a007[Crossref]
  • [10] S. Tokonami, T. Kovács, S. Yoshinaga, T. Ishikawa, Y. Kobayashi, Jpn. J. Health Phys. 43, 131 (2008) http://dx.doi.org/10.5453/jhps.43.131[Crossref]
  • [11] N.H. Harley, I.M. Fisenne, E.S. Robbins, Radiat. Prot. Dosim. 152, 14, (2012) http://dx.doi.org/10.1093/rpd/ncs214[Crossref]
  • [12] C. Papastefanou, J. Environ. Radioactiv. 53, 67 (2001) http://dx.doi.org/10.1016/S0265-931X(00)00109-0[Crossref]
  • [13] B. Skwarzec, J. Ulatowski, D.I. Struminska, A. Borylo, J. Environ. Radioactiv. 57, 221 (2001) http://dx.doi.org/10.1016/S0265-931X(01)00018-2[Crossref]
  • [14] F.P. Carvalho, J.M. Oliveira, Czech J. Phys. 56, 697 (2006) http://dx.doi.org/10.1007/s10582-006-1086-2[Crossref]
  • [15] T. Kovács, J. Somlai, K. Nagy, G. Szeiler, Radiat. Meas. 42, 1737 (2007) http://dx.doi.org/10.1016/j.radmeas.2007.07.006[Crossref]
  • [16] M. Naina, R.P. Chauhanb, S.K. Chakarvarti, Radiat. Meas. 43, 515 (2008) http://dx.doi.org/10.1016/j.radmeas.2008.04.034[Crossref]
  • [17] S.C. Black, E.W. Brethauer. Radiat. Data Rep. 9, 145 (1968)
  • [18] E. Ashraf, M. Khater. J. Environ. Radioactiv. 71, 33 (2004) http://dx.doi.org/10.1016/S0265-931X(03)00118-8[Crossref]
  • [19] Y.D. Parfenov, Atomic Energy Rev. 12, 753 (1974)
  • [20] D.R. Singh, S.R. Nikelani, Health Phys. 31, 393 (1976) [PubMed]
  • [21] B. Skwarzec, J. Ulatowski, D.I. Struminska, A. Borylo, J Environ Radioactiv. 57, 221 (2001) http://dx.doi.org/10.1016/S0265-931X(01)00018-2[Crossref]
  • [22] F.A. Mettler, W. Huda, T.T. Yoshizumi, and M. Mahesh, Radiology 248, 254 (2008) http://dx.doi.org/10.1148/radiol.2481071451[Crossref]
Typ dokumentu
Bibliografia
Identyfikatory
Identyfikator YADDA
bwmeta1.element.-psjd-doi-10_2478_s11532-014-0569-4
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.