Ten serwis zostanie wyłączony 2025-02-11.
Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl

PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Czasopismo
2012 | 10 | 1 | 157-164
Tytuł artykułu

Comparison of biosensors based on gold and nanocomposite electrodes for monitoring of malic acid in wine

Treść / Zawartość
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Amperometric biosensors based on a gold planar electrode and on two types of nanocomposite electrodes consisting of multi-walled carbon nanotubes for the determination of L-malic acid designed for wine-makers were developed. The biosensors designed for wine-makers were constructed by immobilization of L-malate dehydrogenase and diaphorase within chitosan layers on the surface of the electrodes. The coenzyme NAD+ and the electrochemical mediator ferricyanide were present in the measuring solution. The current resulting from re-oxidation of produced ferrocyanide was measured at a working potential of +300 mV against an Ag/AgCl reference electrode. The biosensor based on a gold electrode showed linearity over the range 10–520 µM with a detection limit of 5.41 µM. Calibration curves for biosensors utilizing nanocomposites were obtained both with the linear range of 10 to 610 µM. The detection limits were 1.57 and 1.77 µM, respectively. The biosensors showed satisfactory operational stability (no loss of sensitivity after 30 consecutive measurements) and storage stability (90% of the initial sensitivity after one year of storage at room temperature). The results obtained from measurements of wine samples were in a good correlation with the standard HPLC method. Satisfactory biosensor sensitivity, specificity and stability allowed their successful commercialization.
Słowa kluczowe
Wydawca

Czasopismo
Rocznik
Tom
10
Numer
1
Strony
157-164
Opis fizyczny
Daty
wydano
2012-02-01
online
2011-11-24
Twórcy
  • Biorealis s.r.o.
  • Slovak University of Technology
  • Slovak University of Technology
Bibliografia
  • [1] H.U. Bergmeyer, Methods of enzymatic analysis, metabolites 2: Tria- and dicarboxylic acids, purines, pyrimidines and derivates, coenzymes, inorganic compounds (Wiley-VCH, Weinheim, Germany, 1985)
  • [2] M. Toit, L. Engelbrecht, E. Lerm, S. Krieger-Weber, Food. Bioprocess. Technol. 1, 1 (2010)
  • [3] S. Maicas, I. Pardo, S. Ferrer, Int. J. Food Sci. Technol. 35, 75 (2000) http://dx.doi.org/10.1046/j.1365-2621.2000.00359.x[Crossref]
  • [4] J.L.F.C. Lima, T.I.M.S. Lopes, A.O.S.S. Rangel, Anal. Chim. Acta. 366, 187 (1998) http://dx.doi.org/10.1016/S0003-2670(98)00106-8[Crossref]
  • [5] I. Mato, J.F. Huidobro, M.P. Sanchez, S. Muniategui, M.A. Fernandez-Muino, M.T. Sancho, Food Chem. 62, 503 (1998) http://dx.doi.org/10.1016/S0308-8146(97)00166-0[Crossref]
  • [6] M. Palma, C.G. Barroso, Anal. Chim. Acta. 458, 119 (2002) http://dx.doi.org/10.1016/S0003-2670(01)01527-6[Crossref]
  • [7] T. Perez-Ruiz, C. Martinez-Lozano, V. Tomas, J. Martin, J. Chromatogr. A. 1026, 57 (2004) http://dx.doi.org/10.1016/j.chroma.2003.10.130[Crossref]
  • [8] J. Katrlik, A. Pizzariello, V. Mastihuba, J. Svorc, M. Stredansky, S. Miertus, Anal. Chim. Acta. 379, 193 (1999) http://dx.doi.org/10.1016/S0003-2670(98)00610-2[Crossref]
  • [9] M. Arif, S.J. Setford, K.S. Burton, I.E. Tothill, Analyst 127, 104 (2002) http://dx.doi.org/10.1039/b106400m[Crossref]
  • [10] F. Mazzei, F. Botre, G. Favero, Microchem. J. 87, 81 (2007) http://dx.doi.org/10.1016/j.microc.2007.05.009[Crossref]
  • [11] M. Esti, G. Volpe, L. Micheli, E. Delibato, D. Compagnone, D. Moscone, G. Palleschi, Anal. Chim. Acta. 513, 357 (2004) http://dx.doi.org/10.1016/j.aca.2003.12.011[Crossref]
  • [12] N. Gajovic, A. Warsinke, F.W. Scheller J. Biotechnol. 61, 129 (1998) http://dx.doi.org/10.1016/S0168-1656(98)00029-7[Crossref]
  • [13] N. Gajovic, A. Warsinke, F.W. Scheller, J. Chem. Technol. Biotechnol. 68, 31 (1999) http://dx.doi.org/10.1002/(SICI)1097-4660(199701)68:1<31::AID-JCTB599>3.0.CO;2-A[Crossref]
  • [14] S. Miertus, J. Katrlik, A. Pizzariello, M. Stredansky, J. Svitel, J. Svorc, Biosens. Bioelectron. 13, 911 (1998) http://dx.doi.org/10.1016/S0956-5663(98)00063-3[Crossref]
  • [15] B. Bucur, E. Mallat, A.-M. Gurban, Y. Gocheva, C. Velasco, J.-L. Marty, T. Noguer, Biosens. Bioelectron. 21, 2290 (2006) http://dx.doi.org/10.1016/j.bios.2005.10.022[Crossref]
  • [16] M. Gilis, M. Comtat, Sensor Actuat. B-Chem. 26–27, 417 (1995) http://dx.doi.org/10.1016/0925-4005(94)01630-Z[Crossref]
  • [17] R. Monosik, M. Stredansky, J. Tkac, E. Sturdik, Food Anal. Method. DOI: 10.1007/s12161-011-9222-4 [Crossref]
  • [18] S. Iijima, Nature 354, 56 (1991) http://dx.doi.org/10.1038/354056a0[Crossref]
  • [19] J. Wang, Electroanalysis 17, 7 (2005) http://dx.doi.org/10.1002/elan.200403113[Crossref]
  • [20] G. Li, J.M. Liao, G.Q. Hu, N.Z. Ma, P.J. Wu, Biosens. Bioelectron. 20, 2140 (2005) http://dx.doi.org/10.1016/j.bios.2004.09.005[Crossref]
  • [21] M. Musameh, J. Wang, A. Merkoci, Y. Lin, Electrochem. Commun. 4, 743 (2002) http://dx.doi.org/10.1016/S1388-2481(02)00451-4[Crossref]
  • [22] M. Gamella, S. Campuzano, F. Conzuelo, J.A. Curiel, R. Munoz, A.J. Reviejo, J. M. Pingarron, Talanta 81, 925 (2010) http://dx.doi.org/10.1016/j.talanta.2010.01.038[Crossref]
  • [23] A. Arvinte, L. Rotariu, C. Bala, A.M. Gurban, Bioelectrochemistry 76, 107 (2009) http://dx.doi.org/10.1016/j.bioelechem.2009.04.005[Crossref]
  • [24] A. Arvinte, L. Rotariu, C. Bala, Sensors 8, 1497 (2008) http://dx.doi.org/10.3390/s8031497[Crossref]
  • [25] J. Tkac, T. Ruzgas, Electrochem. Commun. 8, 899 (2006) http://dx.doi.org/10.1016/j.elecom.2006.03.028[Crossref]
  • [26] U.B. Trivedi, D. Lakshminarayana, I.L. Kothari, P.B. Patel, C.J. Panchal, Sens. Actuators, B 136, 45 (2009) http://dx.doi.org/10.1016/j.snb.2008.10.020[Crossref]
  • [27] A.M. Gurman, B. Prieto-Simon, J.L. Marty, T. Noguer, Anal. Lett. 39, 1543 (2006) http://dx.doi.org/10.1080/00032710600713214[Crossref]
  • [28] A.F. Groboillot, C.P. Champagne, G.D. Darling, D. Poncelet, R.J. Neufild, Biotechnol. Bioeng. 42, 1157 (1993) http://dx.doi.org/10.1002/bit.260421005[Crossref]
  • [29] B. Krajewska, Microb. Technol. 35, 126 (2004) http://dx.doi.org/10.1016/j.enzmictec.2003.12.013[Crossref]
  • [30] M. Nishiyama, N. Matsubara, K. Yamamoto, S. Iijima, T. Uozumi, T. Beppu, J. Biol. Chem. 261, 14178 (1986)
  • [31] H. Huang, N.F. Hu, Y.H. Zeng, G. Zhou, Anal. Biochem. 308, 141 (2002) http://dx.doi.org/10.1016/S0003-2697(02)00242-7[Crossref]
  • [32] Y. Tan, W. Deng, B. Ge, Q. Xie, J. Huang, S. Yao, Biosens. Bioelectron. 24, 2225 (2009) http://dx.doi.org/10.1016/j.bios.2008.11.026[Crossref]
  • [33] M.G. Zhang, A. Smith, W. Gorski, Anal. Chem. 76, 5045 (2004) http://dx.doi.org/10.1021/ac049519u[Crossref]
  • [34] Q. Zhou, Q. Xie, Y. Fu, Z. Su, X. Jia, S. Yao, J. Phys. Chem. B 111, 11276 (2007) http://dx.doi.org/10.1021/jp073884i[Crossref]
  • [35] Y. Liu, X.H. Qu, H.W. Guo, H.J. Chen, B.F. Liu, S.J. Dong, Biosens. Bioelectron. 21, 2195 (2006) http://dx.doi.org/10.1016/j.bios.2005.11.014[Crossref]
Typ dokumentu
Bibliografia
Identyfikatory
Identyfikator YADDA
bwmeta1.element.-psjd-doi-10_2478_s11532-011-0118-3
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.