PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Czasopismo
2003 | 1 | 1 | 28-34
Tytuł artykułu

Toxicological evaluation of exposed SPMD membranes

Treść / Zawartość
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
This article is focused on bioassay evaluation of exposed SPMDs. Toxicity testing of SPMD extract is a suitable complementary parameter to chemical analysis. Vtox as an integrative parameter describing toxic properties of extract from membrane and thus a level of contamination of assessed ambient is presented here. Two examples of practical use of Vtox is demonstrated: a course of toxicity throw wastewater treatment plant with industrial inlets and increase of toxicity in surface water body caused by leakages of POPs from industrial plant.
Słowa kluczowe
Wydawca

Czasopismo
Rocznik
Tom
1
Numer
1
Strony
28-34
Opis fizyczny
Daty
wydano
2003-03-01
online
2003-03-01
Twórcy
Bibliografia
  • [1] J.N. Huckins, G.K. Manuweera, J.D. Petty, D. Mackay, J.A. Lebo: “Lipid-Containing Semipermeable Membrane Devices for Monitoring Organic Contaminants in Water”, Environ. Sci. Technol., Vol. 27, (1993), pp. 2489–2496. http://dx.doi.org/10.1021/es00048a028[Crossref]
  • [2] J.N. Huckins, J.D. Petty, C.E. Orazio, J.A. Lebo, R.C. Clark, V.L. Gibson, W.R. Gala, K.R. Echols: “Determination of Uptake Kinetics (Sampling Rates) by Lipid-Containing Semipermeable Membrane Devices (SPMDs) for Polycyclic Aromatic Hydrocarbons (PAHs) in Water”, Environ. Sci. Technol., Vol. 33, (1999), pp. 3918–3923. http://dx.doi.org/10.1021/es990440u[Crossref]
  • [3] J.N. Huckins, J.D. Petty, H.F. Prest, R.C. Clark, D.A. Alvarez, C.E. Orazio, J.A. Lebo, W.L. Cranor, B.T. Johnson: A guide for the use of Semipermeable membrane devices (SPMDs) as samplers of waterborne hydrophobic organic contaminants, Columbia Environmental Research Center, New Haven Road, Columbia, 2000.
  • [4] B.T. Johnson, J.N. Huckins, J.D. Petty, R.C. Clark: “Collection and detection of lipophilic chemical contaminants in water, sediment, soil, and air-SPMD-TOX”, Environmental Toxicology, Vol. 15, (2000), pp. 248–252. http://dx.doi.org/10.1002/1522-7278(2000)15:3<248::AID-TOX10>3.0.CO;2-Q[Crossref]
  • [5] V. Kočí, M. Mlejnek, T. Ocelka, L. Kochánková: “Application of algal bioassay for toxicity evaluation of SPMD”, Czech Phycology, Vol. 2, (2002), pp. 129–137.
  • [6] A. Kot, B. Zabiegala, J. Namiesenik: “Passive sampling for long-term monitoring of organic pollutants in water”, Trends in Analytical Chemistry, Vol. 19, (2000), pp. 446–459. http://dx.doi.org/10.1016/S0165-9936(99)00223-X[Crossref]
  • [7] J.D. Petty, C.E. Orazio, J.N. Huckins, R.W. Gale, J.A. Lebo, J.C. Meadows, K.R. Echos, W.L. Cranor: “Considerations involved with the use of semipermeable membrane devices for monitoring environmental contaminants”, Journal of Chromatography, Vol. 879, (2000), pp. 83–95. http://dx.doi.org/10.1016/S0021-9673(00)00315-0[Crossref]
  • [8] J.D. Petty, S.B. Jones, J.N. Huckins, W.L. Cranor, J.T. Parris, T.B. McTague, T.P. Boyle: “An approach for assessment of water quality using semipermeable membrane devices (SPMDs) and bioindicator tests”, Chemosphere, Vol. 41, (2000), pp. 311–321. http://dx.doi.org/10.1016/S0045-6535(99)00499-3[Crossref]
  • [9] L. Pollumaa, A. Kahru, A. Eisentrager, R. Reiman, A. Maloveryan, A. Ratsep: “Toxicological Investigation of Soils with the Solid-phase Flash Assay: Comparison with Other Ecotoxicological Tests”, ATLA, Vol. 28, (2000), pp. 461–472.
  • [10] D. Sabaliũnas, J.R. Lazutka, I. Sabaliũniené: “Acute toxicity and genotoxicity of aquatic hydrophobic pollutants sampled with semipermeable membrane devices”, Environmental Pollution, Vol. 119, (2000), pp. 251–265. http://dx.doi.org/10.1016/S0269-7491(99)00259-6[Crossref]
  • [11] D. Sabaliũnas and A. Sodergren: “Use of semi-permeable membrane devices to monitor pollutants in water and assess their effects: A laboratory test and field verification”, Environmental Pollution, Vol. 96, (1997), pp. 195–205. http://dx.doi.org/10.1016/S0269-7491(97)00021-3[Crossref]
Typ dokumentu
Bibliografia
Identyfikatory
Identyfikator YADDA
bwmeta1.element.-psjd-doi-10_2478_BF02479255
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.