Renal function impairment during interventional procedures became a real clinical problem. Contrast related nephropathy is the most common cause of renal failure, however, the procedure-related technical troubles may cause unexpected renal dysfunction.Technical failure of EVAR resulting in acute renal dysfunction is presented. The postprocedural occlusion of the right renal artery was treated in chimney technique. Early reintervention allowed the kidney preservation and renal function restoration. It is impossible to avoid all the complications following treatment of aortic aneurysm, but they can be anticipated and comprehensively treated in collaboration with other specialists.
Wydawca

Rocznik
Tom
87
Numer
4
Strony
181-184
Opis fizyczny
Daty
wydano
2015-04-01
otrzymano
2014-05-05
online
2015-07-03
Twórcy
  • Department of General and Vascular Surgery, Poznań University of Medical Sciences, goranm@gazeta.pl
  • Department of Radiology, Poznań University of Medical Sciences
  • Department of Radiology, Poznań University of Medical Sciences
  • Department of Radiology, Poznań University of Medical Sciences
  • Department of Radiology, Poznań University of Medical Sciences
  • Department of Radiology, Poznań University of Medical Sciences
  • Department of General and Vascular Surgery, Poznań University of Medical Sciences
Bibliografia
  • 1. Greenhalgh RM, Brown LC , Kwong GP et al.: Comparison of endovascular aneurysm repair with open repair in patients with abdominal aortic aneurysm (EVAR trial 1), 30-day operative mortality results: randomised controlled trial. Lancet 2004; 364: 843-48.
  • 2. Geijer H, Larzon T, Popek R, Beckman KW : Radiation exposure in stent-grafting of abdominal aortic aneurysms. Br J Radiol 2005; 78: 906-12.
  • 3. Dake MD: Transluminal placement of endovascular stent-grafts for the treatment of thoracic aortic aneurysms. In: Baum S, Pentecost MJ, editors. Abrams’ angiography. 4th ed. Boston, MA: Little, Brown & Company 1997; p. 356-66.
  • 4. Parodi JC, Barone A, Piraino R, Schonholz C: Endovascular treatment of abdominal aortic aneurysms. In: Castaneda-Zuniga WR, ed. Interventional radiology. 3rd ed. New Orleans, LA: Williams & Wilkins 1997; 754-65.
  • 5. Vano E, Goicolea J, Galvan C et al.: Skin radiation injuries in patients following repeated coronary angioplasty procedures. Br J Radiol 2001; 74: 1023-31.
  • 6. Einstein AJ, Sanz J, Dellegrottaglie S et al.: Radiation dose and cancer risk estimates in 16-slice computed tomography coronary angiography. J Nucl Cardiol 2008; 15: 232-40.
  • 7. Incidence of Renal Infarctions After Endovascular AAA Repair: Relationship to Infrarenal Versus Suprarenal Fixation Dittmar Bockler; Martin Krauss; Ulrich Mansmann; Mustafa Halawa,; Ralph Lange; Thomas Probst; and Dieter Raithel, J ENDOVASC THER 2003; 10: 1054-60.
  • 8. Alsac JM, Zarins CK , Heikkinen MA et al.: The impact of aortic endografts on renal function. J Vasc Surg 2005; 41: 926-30.
  • 9. Bove PG, Long GW, Shanley CJ et al.: Transrenal fixation of endovascular stent-grafts for infrarenal aortic aneurysm repair: mid-term results. J Vasc Surg 2003; 37: 938-42.
  • 10. Grego F, Frigatti P, Antonello M et al.: Suprarenal fixation of endograft in abdominal aortic aneurysm treatment: focus on renal function. Ann Surg 2004; 240: 169-78.
  • 11. Greenberg RK , Chuter TA , Sternbergh WC et al.: Zenith AAA endovascular graft: interme- diateterm results of the US multicenter trial. J Vasc Surg 2004; 39: 1209-18.
  • 12. Wald R, Waikar SS , Liangos O et al.: Acute renal failure after endovascular vs open repair of abdominal aortic aneurysm. J Vasc Surg 2006; 43: 460-66.
  • 13. Rashid ST , Salman M, Agarwal S et al.: Occult renal impairment is common in patients with peripheral vascular disease and normal serum creatinine. Eur J Vasc Endovasc Surg 2006; 32: 294-99.
  • 14. Azzizadeh A, Sanchez LA , Miller CC et al.: Glomerular filtration rate is a predictor of mortality after endovascular abdominal aortic aneurysm repair. J Vasc Surg 2006; 43: 14-18.
  • 15. Kappel J, Calissi P: Safe drug prescribing for patients with renal insufficiency. CMAJ 2002; 166: 473-77.
  • 16. Zarins CK , White RA , Schwarten D et al.: AneuRx stent graft versus open surgical repair of abdominal aortic aneurysms: multicenter prospective clinical trial. J Vasc Surg 1999; 29: 292-305.
  • 17. Parmer SS , Carpenter JP: Endovascular aneurysm repair with suprarenal vs infrarenal fixation: a study of renal effects. J Vasc Surg 2006; 43: 19-25.
  • 18. Hobo R, Buth J: Secondary interventions following endovascular abdominal aortic aneu- rysm repair using current endografts. A EURO- STAR report. J Vasc Surg 2006; 43: 896-902.
  • 19. Schermerhorn M, O’Malley J, Jhaveri A et al.: Endovascular vs. open repair of abdominal aortic aneurysms in the Medicare population. N Engl J Med 2008; 358: 464-74.
  • 20. Kalliafas S, Albertini JN, Macierewicz J et al.: Incidence and treatment of intraoperative technical problems during endovascular repair of complex abdominal aortic aneurysms. J Vasc Surg 2000; 31: 1185-92.
  • 21. Love L, Bush IM: Early demonstration of renal collateral arterial supply. Am J Radiol 1968; 104: 296-301.
  • 22. Abrams HL , Cornall SH : Patterns of collateral flow in renal ischemia. Radiology 1965; 84: 1001-12.
  • 23. Parmer SS , Carpenter JP: Endovascular aneurysm repair with suprarenal vs infrarenal fixation: a study of renal effects. J Vasc Surg 2006; 43: 19-25.
Typ dokumentu
Bibliografia
Identyfikatory
Identyfikator YADDA
bwmeta1.element.-psjd-doi-10_1515_pjs-2015-0041
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.