The article provides the results of 31 experimental dives carried out within the depth range of H ∈ [60; 80] mH2O. A combined mathematical model for ventilation and decompression was proposed with the possibility of an emergency omission of the last station at 3 mH2O and decompression completion at 6 mH2O in the event of a deterioration in weather conditions.
Słowa kluczowe
Czasopismo
Rocznik
Tom
Numer
Strony
11-24
Opis fizyczny
Daty
wydano
2015-06-01
zaakceptowano
2015-05-25
online
2015-11-18
Twórcy
autor
- Polish Naval Academy, Department of Underwater Work Technology in Gdynia, Poland
Bibliografia
- 1. Aqua Lung France. 2012. Dive conduct and organization. Nice : Aqua Lung France, 2012. Ref. 490047 A - Ed 16/07/12 - AQUA LUNG - Dive Conduct and Organization. CRABE Apparatus.
- 2. Aqua Lung. 2004. User manual CRABE. Nice : Aqua Lung France, 2004. provisional version 1.12. 2004.
- 3. Ashida H., Ikeda T., Tikuisis P., Nishi R.Y. 2005. Relationship between two different functions derived from diffusion-based decompression theory. Undersea Hyperbaric Medicine. 2005, Vol. 32, pp. 429-435.
- 4. Bühlmann A.A. 1995. Tauchmedizin. Berlin : Springer-Verlag, 1995. ISBN 3-540-58970-8.
- 5. Huggins K.E. 1992. The dynamics of decompression workbook. Ann Arbor : The University of Michigan, 1992.
- 6. Imbert J.P., Fructus X. 1991. Short and repetitive decompressions in air diving procedures: the commercial diving experience. [author of the book] Sciences American Academy of Underwater. Proceedings of Repetitive Diving Workshop. Durham, North Carolina : DUKE University Medical Center, 1991, pp. 63-72.
- 7. Imbert J.P., Hugon J. 2004. In Search of Models Behind Successful Decompressions. [author of the book] SJacquet. Les Tables de Decompression, MT92. Banyuls, Rosselló, Catalunya Nord : Stage de Plongée Scientifique, 2004, pp. 18-32.
- 8. Kłos R. -. 2007. The use of statistical methods in the diving technique. Gdynia : Wydawnictwo Polskiego Towarzystwa Medycyny i Techniki Hiperbarycznej, 2007. ISBN 978-83-924989-2-6.
- 9. -. 2011a. The possibilities of decompression adjustment to CRABE rebreather - assumptions for standard and experimental dives. Gdynia : Polskie Towarzystwo Medycyny i Techniki Hiperbarycznej, 2011a. ISBN 978-83-924989-4-0.
- 10. -. 2011b. Polish Decompression System for CRABE Diving Apparatus. Polish Hyperbaric Research. 2005, Vol. 37, 4, pp. 43-50.
- 11. -. 2012a. Intravascular free gas phase detection. Zeszyty Naukowe Akademii Marynarki Wojennej. 2012a, Vol. 188, ISSN 0860-889X, pp. 85-96.
- 12. -. 2012b. The possibilities of oxygen-nitrox exposure adjustment to AMPHORA rebreather - assumptions for standard and experimental dives.
- Gdynia : Polskie Towarzystwo Medycyny i Techniki Hiperbarycznej, 2012b. ISBN 978-83-924989-8-8.
- 13. -. 2013a. Propose decompression tables for CRABE rebreather and Trimix 23%O_2 36%N_2 41%He. Gdynia : Akademia Marynarki Wojennej, 2013a. Report no. OTM/TULIPAN III/04-2013.
- 14. -. 2013b. Nitrox and Trimix deep water decompression system for CRABE rebreather - Assumptions for experimental dives. Gdynia : Akademia Marynarki Wojennej, 2013b. OTM/TULIPAN III/06-2013.
- 15. -. 2014a. Designing experiments for CRABE rebreather - Assumptions for statistical study on the results of experimental dives. Gdynia : Akademia Marynarki Wojennej, 2014a. Report no. OTM/TULIPAN III/07-2014.
- 16. -. 2014b. Nitrox and Trimix deep water decompression system for CRABE rebreather - Completed assumptions for experimental dives.
- Gdynia : Akademia Marynarki Wojennej, 2014b. Report no. OTM/TULIPAN III/09-2014.
- 17. Shields T.G., Lee W.B. 1986. The incidence of decompression sickness arising from commercial offshore air-diving operations in the UK sector of the North Sea during 1982/83. Report to the UK Department of Energy. Sheffield : Health and Safety Executive, 1986. OTO 97812.
- 18. Williams S. 1975. Engineering principles of underwater breathing apparatus. [author of book] Bennett P.B. Elliott D.H. The physiology and Medicine of diving. London : Bailliere Tidall, 1975, pp. 34-46.
- 19. Woźniak R. 2014. Security preparation for experimental Trimix dives with the use of CRABE rebreather. Gdynia : Akademia Marynarki Wojennej, 2014. Report no. OTM/TULIPAN III/10-2014.