1
Content available remote Przyczyny zawilgacania budynków
PL
Przedmiotem artykułu są zagadnienia dotyczące hydroizolacji budynków. Omówiono w nim warunki gruntowo-wodne rzutujące na dobór odpowiednich do nich izolacji. Przeanalizowano magazynowanie i transport wody w materiałach porowatych, a także zjawiska sorpcji, kondensacji powierzchniowej i dyfuzji pary wodnej.
EN
This paper concerns the issues related with waterproof insulation of buildings. It also describes the soil and water conditions that affect the selection of proper insulation materials. Storage and transfer of water in porous materials, as well as sorption, surficial condensation and water vapour diffusion have been analysed.
PL
W artykule opisano metody intensyfikacji procesów w wymiennikach ciepła stosowanych w urządzeniach chłodniczych i pompach ciepła. Szczególną uwagę zwrócono na procesy dwufazowe i wpływ ich struktury na intensywność procesu przejmowanie ciepła przy wrzeniu i skraplaniu czynników chłodniczych, Oceniono wpływ modyfikacji powierzchni przekazywania ciepła na temperaturę wrzenia i skraplania oraz opory przepływu czynników przez wymienniki ciepła.
EN
The article describes methods of process intensification in heat exchangers used in refrigeration equipment and heat pumps. Particular attention has been paid to two-phase processes and the influence of their structure on the intensity of the process of heat transfer at boiling and condensation of refrigerants. The influence of modification of heat transfer surfaces on the boiling and condensation temperature and resistance of the factors flowing through heat exchangers has been evaluated.
PL
W artykule opisano metody intensyfikacji procesów w wymiennikach ciepła stosowanych w urządzeniach chłodniczych i pompach ciepła. Szczególną uwagę zwrócono na procesy dwufazowe i wpływ ich struktury na intensywność procesu przejmowanie ciepła przy wrzeniu i skraplaniu czynników chłodniczych, Oceniono wpływ modyfikacji powierzchni przekazywania ciepła na temperaturę wrzenia i skraplania oraz opory przepływu czynników przez wymienniki ciepła.
EN
The article describes methods of process intensification in heat exchangers used in refrigeration equipment and heat pumps. Particular attention has been paid to two-phase processes and the influence of their structure on the intensity of the process of heat transfer at boiling and condensation of refrigerants. The influence of modification of heat transfer surfaces on the boiling and condensation temperature and resistance of the factors flowing through heat exchangers has been evaluated.
PL
W artykule opisano metody intensyfikacji procesów w wymiennikach ciepła stosowanych w urządzeniach chłodniczych i pompach ciepła. Szczególną uwagę zwrócono na procesy dwufazowe i wpływ ich struktury na intensywność procesu przejmowanie ciepła przy wrzeniu i skraplaniu czynników chłodniczych, Oceniono wpływ modyfikacji powierzchni przekazywania ciepła na temperaturę wrzenia i skraplania oraz opory przepływu czynników przez wymienniki ciepła.
EN
The article describes methods of process intensification in heat exchangers used in refrigeration equipment and heat pumps. Particular attention has been paid to two-phase processes and the influence of their structure on the intensity of the process of heat transfer at boiling and condensation of refrigerants. The influence of modification of heat transfer surfaces on the boiling and condensation temperature and resistance of the factors flowing through heat exchangers has been evaluated.
EN
Combi-steamer condensation hoods are widely used in modern gastronomy. They condense steam produced by the combi-steamer and also filter solid particles, moisture, grease and smells. All these factors negatively affect the staff and dishes, so efficient work of the condensation hoods becomes important. A mathematical and experimental analysis of such a device is described in this paper. First a measurement methodology was designed and measurements of air humidity, temperature and mass flow rates were performed. The measurement procedure concerned dedicated a steam generator and combi-steamer. Next a mathematical model was developed. It was based on mass and energy balances of the condensation hood. The condensate flow rate turned out to be insufficient to fulfill the energy balance while measured directly. Hence, it was calculated from heater’s power of the steam generator and the balance model was validated. The combisteamer had an unknown output, so the condensate flow rate was provided by the balance model after its validation. A preliminary diagnosis of the device was carried out as well.
PL
W artykule przedstawiono model matematyczny kondensacyjnego wymiennika ciepła typu spaliny-woda, służącego do odzysku niskotemperaturowego ciepła odpadowego ze spalin bloku energetycznego węglowego. Model ten bazuje na modyfikacji modelu Colburna-Hougena, przedstawionej w pracach [17, 24, 33]. W modelu założono, że część wykroplonej pary wodnej reaguje z częścią strumienia dwutlenku siarki w spalinach, wskutek czego powstaje kwas siarkowy (IV). Przy pomocy powyższego modelu przeprowadzono analizę porównawczą wyników obliczeń dla spalin pochodzących z węgla kamiennego i brunatnego. Przeprowadzono optymalizację wymiennika ciepła pod względem wybranych parametrów.
EN
The aim of the article is to present a mathematical model of flue gases-water condensing heat exchanger used for the recovery of low temperature waste heat of coal-fired power unit. This model is based on the modification of the Colburn-Hougen model, presented in [17, 24, 33]. In addition, it was assumed that some of the condensed water vapor reacts with a portion of the sulfur dioxide stream in exhaust, resulting in formation of sulfuric acid (IV). With this model, a comparative analysis of calculation results for flue gases derived from lignite and bituminous coal was performed. The heat exchanger has been optimized for selected parameters.
EN
In this paper, the steady three-dimensional problem of condensation film on an inclined rotating disk is considered. The governing nonlinear partial differential equations are reduced to the nonlinear ordinary differential equations system by a similarity transform. The equation system is solved by the variation of parameters method (VPM) which is rather used to solve nonhomogeneous linear differential equations but can also be used to solve nonlinear differential equations. This method has not previously been used to solve a nonlinear condensation problem. The dimensionless velocity and temperature profiles are shown, and the influence of Prandtl number and rotation ratio on the flow field and the Nusselt number are discussed in detail. In order to assess the accuracy of the solutions obtained by this method, the problem is also solved numerically using the Matlab bvp4c solver. The validity of our solutions is verified by the numerical results.
EN
Helical coil heat exchangers are widely used in a variety of industry applications such as refrigerationsystems, process plants and heat recovery. In this study, the effect of Reynolds number and theoperating temperature on heat transfer coefficients and pressure drop for laminar flow conditions wasinvestigated. Experiments were carried out in a shell and tube heat exchanger with a copper coiledpipe (4 mm ID, length of 1.7 m and coil pitch of 7.5 mm) in the temperature range from 243 to 273 K.Air – propan-2-ol vapor mixture and coolant (methylsilicone oil) flowed inside and around the coil,respectively. The fluid flow in the shell-side was kept constant, while in the coil it was varied from 6.6to 26.6 m/s (the Reynolds number below the critical value of 7600). Results showed that the helicalpipe provided higher heat transfer performance than a straight pipe with the same dimensions. Theconvective coefficients were determined using the Wilson method. The values for the coiled pipe werein the range of 3–40 W/m2·K. They increased with increasing the gas flow rate and decreasing thecoolant temperature.
EN
The image analysis consists in extracting from the information which is available to the observer of the part that is important from the perspective of the investigated process. This process usually accompanies a considerable reduction in the amount of information from the image. In the field of two-phase flows, computer image analysis can be used to determine flow and geometric parameters of flow patterns. This article presents the possibilities of using this method to determine the void fraction, vapor quality, bubble velocity and the geometric dimensions of flow patterns. The use of computer image analysis methods is illustrated by the example of HFE 7100 refrigerant methoxynonafluorobutane condensation in a glass tubular minichannel. The high speed video camera was used for the study, and the films and individual frames received during the study were analyzed.
10
Content available Wilgoć w budynkach zabytkowych
PL
Wilgoć jest głównym zagrożeniem dla zabytków. Prowadzi bezpośrednio do degradacji substancji zabytkowej oraz uruchamia procesy niszczące niewystępujące bez jej udziału. Poprawne rozpoznanie źródeł zawilgocenia pozwala na podjęcie odpowiednich kroków w stronę skutecznej i trwałej renowacji. Jednak właściwa diagnoza często nie jest łatwa, a z pozoru oczywiste obserwacje mogą owocować sformułowaniem błędnych wniosków i wdrożeniem działań, które przyniosą więcej szkody niż pożytku. Artykuł opisuje najczęstsze przyczyny powstawania zawilgoceń w budynkach zabytkowych oraz zwraca uwagę na podstawowe czynniki, które należy wziąć pod uwagę, chcąc uniknąć nieskutecznych i kosztownych napraw. Szczególnie podnosi problem tzw. wilgoci wstępującej od gruntu, zdecydowanie zbyt często i łatwo wskazywanej jako główny powód zawilgocenia.
EN
Dampness is considered to be one of the most serious threats to heritage buildings. It leads directly to degradation of historical fabric and triggers damaging processes that would not appear without it. Correct diagnosis of the source of damp is necessary for implementing appropriate measures that will lead to effective and lasting renovation. But making a correct diagnosis is not easy, and what appears obvious from observation can lead to formulating incorrect conclusions and actions, which do more harm than good. The paper describes the most common causes of dampness in heritage buildings and draws attention to the basic factors, which need to be taken into account, in order to avoid ineffective and costly repairs. Special attention is devoted to the so-called damp rising from the ground, which is too often and too easily implicated as the main cause of dampness.
PL
W pracy zaprezentowano rozpływ pary w wymienniku ciepłowniczym. Analizę oparto na wynikach z symulacji numerycznej przeprowadzonej dla wymiennika o mocy cieplnej 167 MW, 134,4 MW i 66 MW. Wykorzystano model dwuwymiarowy oparty na założeniu pojedynczego kontinuum w ustalonych warunkach procesu. Wewnątrz wymiennika przepływa idealna para wodna nasycona. Pęk rur traktowany jest jako złoże porowate. Przeanalizowano wyniki rozpływu pary w wymienniku i zaproponowano rozmieszczenie rur o zwiększonej grubości ścianek.
EN
The work presents the steam distribution in the heat exchanger. The analysis was based on the results of numerical simulation carried out for the heat exchanger with 167 MW, 134.4 MW and 66 MW thermal capacity. A two-dimensional model based on the assumption of a single continuum under fixed process conditions was used. The inside of the heat exchanger is saturated water vapor. The pipe bend is treated as a porous deposit. The results of the steam distribution in the exchanger were analyzed and the distribution of pipes with increased wall thickness was proposed.
EN
A poly(hydroxybutyl citrate) p(HBC) was obtained. The product compound produced in the solution during esterification, was added to rigid polyurethane-polyisocyanurate foams (PUR-PIR). The amount of petrochemical polyol in the foams was decreased in favor of the p(HBC) from 0.1 to 0.5 equivalent. The foams were foamed in two ways: with distilled water (W foams) and with Solkane 365/227 (S foams). The examination results of both foam series were compared. They showed that the foams foamed with water have higher softening temperature than the foams foamed with solkane. The retention values for both foam series are around 91–95%, and water absorption in the range of 0.7–3.2%. The anisotropy coefficient did not exceed 1.08 (the lowest value being 1.01).
13
EN
Proposed is the analysis of steam condensation in the presence of inert gases in a power plant condenser. The presence of inert, noncondensable gases in a condenser is highly undesirable due to its negative effect on the efficiency of the entire cycle. In general, thermodynamics has not provided an explicit criterion for assessing the irreversible heat transfer process. The method presented here enables to evaluate precisely processes occurring in power plant condensers. This real process is of particular interest as it involves a number of thermal layers through which heat transfer is observed. The analysis was performed using a simple, known in the literature and well verified Berman’s model of steam condensation in the presence of non-condensable gases. Adapted to the geometry of the condenser, the model enables, for instance, to recognise places where non-condensable gases are concentrated. By describing with sufficient precision thermodynamic processes taking place in the vicinity of the heat transfer area segment, it is possible to determine the distributions of thermodynamic parameters on the boundaries between successive layers. The obtained results allow for the recognition of processes which contribute in varying degrees to irreversible energy degradation during steam condensation in various parts of the examined device.
15
Content available remote Hexahydroquinoline derivatives : synthesis and anti-hepatoma cancer activity
EN
Arom. aldehydes were condensed in EtOH under boiling, pptd. by cooling to the room temp., sepd. by filtration, dried under vacuum and studied for anticancer activity against 3 human hepatoma tumor cell lines (SMMC-7721, BEL-740 and HCCLM3). Normal fibroblast cells WI 38 were also used. Fluorouracil was used as a ref. anticancer agent. One of the synthesized comps. showed a high inhibitory effect against 3 tumor cell lines (higher than the ref. agent). The compd. was non-cytotoxic to normal cells (IC50 values higher than 100 μg/mL).
PL
Przedstawiono syntezę i charakterystykę 4 pochodnych heksahydrochinoliny. Związki te zsyntetyzowano w reakcji kondensacji różnych aldehydów aromatycznych i oceniono pod kątem właściwości antyrakowych na podstawie badania 3 ludzkich linii komórkowych raka wątrobowokomórkowego (SMMC-7721, BEL-740 i HCCLM3). W badaniu wykorzystano także komórki WI 38 jako normalne fibroblasty. Najlepsze wyniki uzyskano dla związku 4, który wykazał najskuteczniejsze działanie hamujące rozwój 3 linii komórek rakowych. Działanie to okazało się skuteczniejsze niż w przypadku referencyjnego fluorouracylu. Ponadto związek ten nie działał cytotoksycznie na normalne komórki (IC₅₀ > 100 μg/mL).
EN
In the present paper, an attempt was made to model the periodic hydrodynamic instabilities of the condensation process of a refrigerant in pipe minichannels. For this purpose, a homogenous thermodynamic model with an equilibrium condition on both sides was used, which was based on the equations of the balance of the mass, momentum and energy. These equations were used for numerical modeling of flow disturbances with a phase change. This model takes into account the complexity of multiphase flows. The accuracy of the model calculations was verified by means of the experimental results obtained. A satisfactory compliance was found for this comparison, which confirms the usefulness of the computational model proposed for the determination of the influence of periodically generated hydrodynamic disturbances on the condensation process of R134a and R404A refrigerants in pipe minichannels.
17
Content available Flow structures during refrigerants condensation
EN
For several years, in the world are carried out studies on the refrigerants condensation in minichannels. These studies are aimed at understanding the condensation process and facilitate the design of mini heat exchangers. It is very important to optimize heat transfer and drive power consumption of the is the knowledge of the processes occurring during refrigerants condensation in pipe minichannels. It is important in this case to make a individual flow structures maps for the refrigerants, due to the significant effect of flow structured formed in the minichannel on the heat transfer and flow resistance. Unfortunately, in relation to the number of publications about condensation in minichannels, the number of published flow maps is relatively small. Due to the fact that the condensation process takes place differently in the minichannels and conventional channels, there is no possibility of using the flow maps for conventional channels to identification flow patterns in minichannels. One of the most popular flow maps for the condensation in minichannels is the map created by Colleman and Garimella, which was made for the R134a refrigerant. The authors conducted their own experimental studies of refrigerants R134a, R404A and R407C condensation in pipe minichannels with an internal diameter d = 3.3 - 0.31 mm. These studies results were subjected to calculation identification of flow structures using the map of Colleman and Garimella. These results are compared with the criteria published on Thome and Cavallini flow maps.
PL
Celem pracy było zbadanie procesów odpowiedzialnych za powstawanie i właściwości aerozoli uwalnianych z elektronicznych papierosów. Wykorzystując dyfraktometr laserowy określono podstawowe parametry objętościowego rozkładu wielkości kropel aerozolu uwalnianego z czterech modeli e-papierosów różniących się wewnętrznym oporem aerodynamicznym. Aerozole zostały wytworzone w warunkach odpowiadającym fizjologicznym wartościom przepływu powietrza z płynów zawierających składniki powszechnie występujące w e-liquidach. Stwierdzono, że jakość uwalnianego aerozolu zależy przede wszystkim od konstrukcji urządzenia, ale także od składu i właściwości e-liquidów.
EN
The aim of this work was to investigate the processes responsible for generation and properties of aerosols released from electronic cigarettes. Based on the laser diffraction method the primary parameters of droplet size distribution of aerosols released from four e-cigarette models with different internal aerodynamic resistance were determined. Aerosols were generated at physiological flow rates from e-liquids with different composition and properties. It was stated that the quality of aerosol depends mainly on device construction but it is also related to e-liquid composition and properties.
PL
W pracy przedstawiono wyniki badań eksperymentalnych wymiany ciepła oraz spadku ciśnienia podczas skraplania mieszanin zeotropowych R407C i R410A w minikanałach rurowych o średnicy wewnętrznej d = 0,31 ÷ 3,30 mm. Wyznaczono wartości lokalne i średnie współczynnika przejmowania ciepła a i oporów przepływu (Δp/L) w całym zakresie zmiany stopnia suchości (x = 1÷ 0). Na podstawie uzyskanych wyników badań zilustrowano wpływ zmiany stopnia suchości pary czynnika x, gęstości strumienia masy G oraz średnicy wewnętrznej kanału d na wartość badanych parametrów. Wskazano na wyraźny wpływ właściwości czynnika chłodniczego na charakterystyki cieplno-przepływowe skraplania w minikanałach rurowych. Wyniki badań porównano z wynikami obliczeń według zależności innych autorów. Zastosowany przedział rozbieżności wynosił ±50%. Na podstawie uzyskanych wyników badań opracowano własną korelację do obliczenia współczynnika przejmowania ciepła i oporów przepływu badanych czynników uzyskując zgodność z wynikami badań w zakresie ±25%.
EN
In the work results of experimental studies on heat transfer and pressure drop during condensation of R407C and R410A zeotropic refrigerants in pipes minichannels with internal diameter or d = 0.31 ÷ 3.30 mm were presented. Local and average values of heat transfer coefficient a and flow resistance (Δp/L) were calculated for the whole range of vapor quality change (x = 1 ÷ 0). Based on the obtained results, the influence of vapor quality changes x, the mass flux density G and the internal diameter of channel d on the values of the investigated parameters are illustrated. The effect of the refrigerant properties on the heat and flow characteristics during condensation was clearly indicated. The study results were compared with the results of calculations according to the correlations of other authors. The used range of accuracy was about ± 50%. On the basis of the obtained results, has been developed own correlation to calculate the heat transfer coefficient and the flow resistance of the tested refrigerants which describe phenomena with the accuracy of ± 25%.
PL
Celem pracy jest sprawdzenie wystąpienia kondensacji pary wodnej w stropodachu zielonym, będącym pokryciem budynku mieszkalnego wielorodzinnego, dla którego określono trzecią klasę obciążenia wilgocią - budynki o niskim stopniu zaludnienia. Stropodach cechuje się układem warstw, w których zmiennej grubości termoizolacja jest układana ze spadkiem w kierunku koryta odwadniającego. Minimalna grubość termoizolacji to 25 cm, a maksymalna będąca wynikiem obliczeń, to około 31,5 cm. Wyznaczając grubość termoizolacji w poszczególnych miejscach stropodachu posłużono się krokiem wynoszącym 50 cm tworząc siatkę punktów opisujących poszczególne przekroje stropu. Sprawdzenia dokonano w oparciu o definicję współczynnika temperaturowego. Średnie miesięczne wartości temperatury na zewnątrz budynku uzyskano w oparciu o bazę danych Instytutu Meteorologii i Gospodarki Wodnej za rok 2015. Na początku obliczono miesięczne zewnętrzne ciśnienie pary wodnej. Następnie wyznaczono zewnętrzne ciśnienie pary wodnej oraz nadwyżkę wewnętrznego ciśnienia pary wodnej w sposób odpowiedni dla trzeciej klasy obciążenia wilgocią. Kolejno obliczenie wewnętrznego ciśnienia pary wodnej i minimalnego dopuszczalnego ciśnienia pary nasyconej doprowadziło do obliczenia minimalnej dopuszczalnej temperatury na powierzchni przegrody. Dla założonego układu warstw dachowych nie występuje ryzyko wystąpienia kondensacji pary wodnej, a co za tym idzie uniknięto wystąpienia pleśni i grzybów wewnątrz budynku. Ma to bardzo duże znaczenie nie tylko estetyczne, ale szczególnie ważne wobec osób cierpiących na alergię. Uniknięcie wszelkiego rodzaju grzybów i pleśnie w pomieszczeniu pomaga stworzyć właściwy mikroklimat.
EN
The aim is to check the occurrence of condensation on the flat roof of green, which is covering multifamily residential building, for which specified third class load damp - buildings with low population. Flat roof has a layer system in which the variable thickness of insulation is laid with a fall in the direction of the irrigation channel. The minimum thickness of insulation is 25 cm and the maximum result of the calculation, is about 31.5 cm. Determining the thickness of the insulation in the various places of the flat roof was used in increments of 50 cm to form a grid of points that describe the individual sections of the floor. Checks were made on the basis of the definition of the temperature coefficient. The average monthly temperature on the outside of the building was achieved based on the database of the Institute of Meteorology and Water Management for the year 2015. At the beginning of calculated monthly external pressure steam. Then they set the external pressure steam and excess internal pressure steam in a manner appropriate for the third class of moisture load. Successively calculating the internal vapor pressure and the minimum allowable vapor pressure led to calculate the minimum allowable surface temperature of the partition. For founded the layers of the roof there is a risk of condensation. This is very important not only aesthetic, but especially important for people with allergies. Avoiding all kinds of fungi and molds in the room helps to create the right microclimate.