Among the most significant sources of microplastics (MPs) for humans is indoor dust. However, very few researchers have studied the properties and abundance of MPs that existed in dust from different indoor environments. The current study investigated microplastic fallout in 90 locations (5 kindergartens, 6 mosques, 5 schools, 10 shops, 5 cafeterias, 6 hospitals, 25 dormitories, 7 barber salons, 6 offices, 5 scientific laboratories, 5 pharmacies, and 5 medical clinics) during six months. Among the ninety sampling sites, the most significant average of MPs was actually found in the kindergartens (4.743×103 ± 427 MP/m2 /d), in contrast, the lowest abundance was in the medical clinics (3.02×102 ± 62 MP/m2 /d). The majority of indoor dust samples contained MPs in the form of fibers. The dominant colour of dust samples was transparent, followed by black, red, blue, green, and yellow. A total of six types of polymers were identified, including polystyrene (PS, 39%), polyethylene terephthalate (PET, 20%), polypropylene (PP, 17%), polyethylene (PE, 13), polyamide (PA, 7%) and polyvinyl chloride (PVC, 3%). PS, PET, and PP represent most of the MPs polymer types discovered in indoor dust samples from various locations. These polymers are frequently used in fabrics, furniture, carpets, packaging, and synthetic fibers. Statistical analysis was performed on the results using Excel 2019. The results showed that there were statistically significant differences in each site with the other sites, except between (schools and mosques), (pharmacies, and medical clinics). The similarity between these sites in terms of people’s activity or in terms of furniture, the lack of carpets and curtains could explain the insignificant difference.
The paper deals with the subject of increasing the efficiency of air purification in ventilation systems in situations of unusual hazardous indoor air pollutants. It analyzes possible locations of additional filtering and sterilizing elements in the installation to eliminate their return to the rooms. The quantities of pollutants in particular parts of the system were determined for a given fan configuration in the air handling unit and a possible leakage in the heat recovery system. Guidelines were proposed for the design and construction of systems to enable rapid modification of systems in the event of unusual contamination or pathogens in the indoor air.
W doborze i ocenie poszczególnych systemów powinniśmy kierować się przede wszystkim komfortem osób, które będą z nich korzystały. Dopiero, gdy wiemy jakie są konkretne oczekiwania, dobieramy najekonomiczniejsze i najbardziej ekologiczne rozwiązanie.
Indoor air quality broadly refers to the environmental characteristics inside buildings and characterizes the physical, chemical and biological state of indoor air at some place and time. Usually it is characterized by physicochemical properties of indoor environment such as temperature, relative humidity, airflows and concentration of characteristic pollutants, e.g. carbon dioxide. They are highly variable in time. In the paper, changes of empirical cumulative distribution function (ECDF) of CO2 concentration were considered as a descriptor of indoor air variability. Using this measure, there may be performed the analysis of CO2 variation in a short as well as long term. The approach utilizes the idea of classification. A class of variation of CO2 concentration has its individual ECDF. It indicates a particular case of balance/imbalance between CO2 delivery and removal processes, including gas dispersion. The analysis is applicable for evaluating the stability of indoor environment and it may provide support for the diagnosis of the performance of the air exchange system. Exemplary results were provided for an open space office and a lecture theater.
Cel: Opis ilościowy skutków zdrowotnych zatruć tlenkiem węgla w Polsce, ich rozkładu terytorialnego i zmian w czasie, oraz ich związku z wybranymi wskaźnikami warunków mieszkaniowych i klimatycznych. Projekt i metody: Analiza opisowa oparta na danych z rejestracji zgonów prowadzonej przez Główny Urząd Statystyczny w latach 2000-2011 oraz na danych z Ogólnopolskiego Badania Chorobowości Szpitalnej Ogólnej prowadzonego przez Narodowy Instytut Zdrowia Publicznego – Państwowy Zakład Higieny w latach 2005-2011. Wyniki: W latach 2000-2011 rocznie rejestrowano w całej Polsce między 331 a 418 zgonów spowodowanych zatruciem gazami. Obserwowano nieznaczny spadek współczynników zgonów w okresie objętym analizą, jednak umieralność w Polsce była wyższa niż w większości krajów Europy, dla których dostępne były dane. Umieralność różniła się ponad dwukrotnie między województwami. W latach 2005-2011 przyjmowano do szpitali między 2557 a 5026 pacjentów zatrutych tlenkiem węgla rocznie. Średnie miesięczne liczby hospitalizacji w miesiącach zimowych (listopad-marzec) były 4-7 razy większe niż w pozostałych miesiącach (kwiecień-październik). Miesięczna częstość hospitalizacji była wyrażnie skorelowana z temperaturą powietrza i jej wzrost ze spadającą temperaturą zaznaczał się szczególnie wyraźnie przy średnich temperaturach miesięcznych poniżej 10ºC. Obserwowano ponad pięciokrotną różnicę częstości hospitalizacji między województwami, jednak związek tej zmienności z wojewódzkimi wskaźnikami umieralności spowodowanej zatruciami CO, jak również wojewódzkimi wskaźnikami warunków mieszkaniowych był słaby. Narażenie na dym, ogień i płomienie było przyczyną 6% hospitalizacji osób zatrutych CO. Wnioski: Częstość zatruć tlenkiem węgla w Polsce jest większa niż w większości krajów Europy. Można przypuszczać, że zatrucia te są najczęściej spowodowane ulatnianiem się tlenku węgla z niesprawnych urządzeń domowych i niedostateczną wentylacją. Koszt zdrowotny zatruć CO w Polsce jest istotny i wyraża się tysiącami osób tracącymi zdrowie i życie na skutek dobrze znanej, i teoretycznie możliwej do uniknięcia, trucizny.
EN
Objective: The quantitative assessment of the health effects due to carbon monoxide poisoning in Poland, their spatial and temporal distribution as well as their relation to the selected indicators of housing and climatic conditions. Material and methods: The descriptive analysis based on the data from mortality registration of the Central Statistical Office in 2000-2011 and on the data from the Polish General Hospital Morbidity Study managed by the National Institute of Public Health in 2005-2011. Results: Between 331 and 418 deaths due to exposure to gases were registered annually in Poland in 2000-2011. A slight decline of mortality in the period covered by the analysis was observed, but the mortality in Poland was higher than in most of the European countries for which data are available. There were more than two-fold differences in mortality between the regions of Poland. In 2005-2011, between 2557 and 5026 patients annually were treated for toxic effects of carbon monoxide in hospitals. The monthly number of hospital admissions in winter months (November-March) was 4-7 times higher than in the other part of the year (April-October). Monthly hospital admission rates were highly correlated with ambient air temperature and their increase with the declining temperature was especially clear at mean monthly temperature below 10ºC. There were more than five-fold differences in hospital admission rates between the regions. However the associations of the region-specific hospitalization rates with mortality due to CO poisoning or with region-specific indicators of housing conditions were weak. Exposure to smoke, fire and flames was the external cause of 6% of cases hospitalized for treatment of toxic effects of CO. Conclusions: The frequency of carbon monoxide poisoning in Poland is greater than in majority of European countries. There are reasons to assume that the poisonings are most often caused by the escape of carbon monoxide from malfunctioning house equipment and by insufficient ventilation. Health burden of carbon monoxide poisoning in Poland is significant, amounting to thousands of people sick or killed by a well-known and potentially avoidable poison.
Potential human health effects of material emissions in new car cabins are of great public concern. In present work, four new cars with different equipment were tested to assess the nature of volatile organic compounds (VOCs) associated with new vehicle interior. Air samples were collected on solid sorbents and analyzed using thermal desorption and GCMS/FID. Different types of sorbents were applied to effectively adsorb VOCs. The maximal number of VOCs, trapped from the in-vehicle air, was identified and compounds occurring in air from cabins of all examined vehicles were selected and classified. VOCs emission from identified compounds was calculated and potential sources of identified VOCs were discussed. For aromatic hydrocarbons, the comparison of individual VOCs concentrations was performed.
PL
Potencjalny wpływ na ludzkie zdrowie wywierany przez emisję związków z materiałów występujących w kabinach nowych samochodów jest tematem wywołującym wiele emocji. W niniejszej pracy zbadano cztery nowe samochody z różnym wyposażeniem w celu określenia charakteru lotnych związków organicznych (LZO) pochodzących z wnętrza nowych pojazdów. Próbki powietrza pobierano na adsorbenty stałe i analizowano z wykorzystaniem techniki desorpcji termicznej sprzężonej z GC-MS/FID. Zastosowano różne typy adsorbentów celem efektywnej adsorpcji LZO. Zidentyfikowano maksymalną liczbę LZO pobranych z powietrza wewnątrz samochodu, a także wyodrębniono i sklasyfikowano związki występujące w kabinach wszystkich badanych pojazdów. Wyznaczono emisję pochodzącą od zidentyfikowanych LZO oraz przeprowadzono dyskusję potencjalnych źródeł pochodzenia zidentyfikowanych związków. Dla węglowodorów aromatycznych porównano stężenia poszczególnych zidentyfikowanych związków.
This paper deals with the acceptability (AKC) and perceived concentration of pollutants (D) emitted by occupants in relation to the specific enthalpy (h) and relative humidity (q>) of indoor air. Measurements of AKC/D/, described by semilogarithmic function depend significantly on both In h and In (p. The equation fits to the data published in the literature in a reasonably good way. Therefore, it indicates that the linear function between AKC and h which is commonly used in literature yields rough approximations. The proposed equation allows for the validation of the indoor microclimate and brings an idea how to make measurements of the perceived air quality instrumentally and how to control the air conditioning process.
PL
Praca dotyczy akceptowalności powietrza wewnętrznego (AKC) i wyczuwalnej koncentracji zanieczyszczeń (D) emitowanych przez użytkowników pomieszczeń dydaktycznych i biurowych. Zagadnienia te przedstawiono w relacji do entalpii właściwej (h) i wilgotności względnej powietrza wewnętrznego ((p). Wyniki określania AKC/D/, opisane funkcją logarytmiczną wskazują na wyraźną ich zależność od In h jak również od In cp. Użytą funkcję logarytmiczną z zadawalającym skutkiem dopasowano także do danych literaturowych. Wyciągnięto stąd wniosek o przybliżonym charakterze powszechnie przyjmowanej liniowej zależności pomiędzy AKC i h. Zaproponowane w pracy równanie pozwala na wartościowanie mikroklimatu pomieszczeń oraz wskazuje, w jaki sposób można instrumentalnie określać wyczuwalną jakość powietrza wewnętrznego i w jaki sposób sterować procesem klimatyzacji pomieszczeń.
The nature and concentration of aerosol particles affect the classroom indoor air quality and have a significant impact on children's and youth's health. The results of investigation of trace elements concentrations, grain size and mineral distribution of aerosol particles and precipitation inside one of the classrooms in Lublin University of Technology have been presented. They were compared with the results of investigation of outdoor aerosols and precipitation. A significant difference between the indoor and outdoor particulate matter was shown. The indoor aerosols contained more Ca and K, while Fe and Pb predominated in outdoor aerosols. The attempt to identify sources of pollution in the classroom indoor air was undertaken on the basis of these results. It was emphasized that quantitative data from studies of aerosol particles in classrooms could play an important role in determination of students' exposure to specific contaminants connected with inhaled aerosols. Utility of such investigations for activities which eliminate sources of hazardous aerosols in schools was also pointed out.
PL
W pracy przedstawiono wyniki badania zawartości pierwiastków śladowych, składu ziarnowego i mineralnego cząstek aerozolowych i cząstek osiadłego pyłu w jednej z sal ćwiczeniowych Politechniki Lubelskiej. Porównano je z wynikami takich samych badań dla cząstek aerozolowych i osiadłego pyłu na zewnątrz budynku. Porównanie to wykazało znaczące różnice w jakości i zawartości części stałych w powietrzu wewnętrznym i zewnętrznym. Cząstki aerozolowe wewnątrz pomieszczenia zawierały więcej Ca i K, natomiast na zewnątrz budynku zawierały więcej Fe i Pb. Na podstawie uzyskanych danych podjęto próbę identyfikacji źródeł aerozolowych skażeń powietrza wewnątrz sali. Zwrócono uwagę na znaczenie badań cząstek aerozolowych przy ocenie ekspozycji studentów (uczniów) na określone, specyficzne skażenia znajdujące się we wdychanym przez nich powietrzu. Wskazano również na użyteczność takich badań dla działań mających na celu eliminację źródeł niebezpiecznych, aerozolowych skażeń w szkołach.
Prace badawcze niemieckiego Urzędu Federalnego Badań Naukowych ds. Materiałów zidentyfikowały pochodzenie szkodliwych lotnych substancji organicznych (VOC), a w szczególności trudno lotnych substancji organicznych (SVOC), wydzielających się podczas drukowania i kopiowania na urządzeniach laserowych, także na papierach makulaturowych. Wnioski z tych badań są następujące: o Źródłem emitowanych substancji są zawarte w papierach makulaturowych pozostałości farb offsetowych; o Dzięki odbarwianiu makulatury wielkość emisji zostaje wyraźnie zmniejszona, gdyż już prosta flotacja prowadzi do jej redukcji o blisko 50%; o Przez staranny dobór drukarki laserowej można znacznie ograniczyć emisje: TVOC - do 25 razy, a TSVOC -do 7 razy. Wpływ typu drukarek może być tym samym większy, niż zastosowanego papieru; o Przy nakładzie 100 stron dziennie wszystkie badane papiery spełniały wymagania schematu oceny AgBB dla materiałów budowlanych. Można więc założyć, że zadrukowanie papierów makulaturowych nie stwarza zagrożenia zdrowotnego.
EN
The research works of the German Federal Office of the Scientific Research Works on the Materials have identified the origin of the volatile organic compounds (VOC) and particularly the slowly volatile organic compounds (SVOC) arising during printing and copying on the laser equipment. Besides this the health tests have been carried out on the health aspects of these compounds from the reclaimed papers. The conclusions are as follows: o The source of the VOC and SVOC emitted during printing on the papers made from the secondary fibres are the offset inks left in these papers. o Waste paper deinking considerably decreases the emissions, since simple floatation alone brings about the 50% their reduction. o By careful selection of the laser printer the emissions can be considerably reduced: by multiple 25 for TVOC and by multiple 7 in case of TSVOC. The impact of these printers type can be thus greater than of the paper's origin. o At an edition amounting to 100 pages daily alt the tested papers fulfilled the requirements of an evaluation pattern AgBB for the building materials. Thus it can be assumed, that printing on the deinked secondary fibre based papers does not create a health risk.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.